5. Settings

5.1 Setting the protocol

The Ethernet bus module supports various real time Ethernet bus systems. The desired system can be selected using the rotary switch “Protocol”. For ProfiNet this needs to be set to 0.

5.2 Setting the number of slots

The number of devices which are connected to the Ethernet bus module is set with the rotary switch “Slots”. After switching on, the Ethernet bus module reads all the parameters of the device. Following this it starts communicating.

Attention: To change the number of slots when switched on, the switch “Slots” must first be turned to 0. Communication with the master is then interrupted. Following this the desired number can be set. After leaving the position 0 you have about 2 seconds time for this.

5.3 Setting the device name

Every IO device is identified by its device name. The setting of the device name can be undertaken using, for example, the program “Step 7 – HW Config” in the menu “Target system / Ethernet / Edit Ethernet participant…”

Fig. 1 Configuration & LED displays

1Terminal X1

2Terminal X2

3Terminal X3

4Terminal X4

5Terminal X5

6Terminal X6

7Terminal X7

8Terminal X8

9Ethernet Port

10Terminal X11

11SYS LED

12COM0 (BF) LED

13COM1 (SF) LED

14Fault LED

15Switch Slots

16Switch Protocol

12

Image 12
Contents Ethernet Bus Module ProfiNet Contents List of figures and tables Contact Introduction Safety Identification in the operating instructionsGeneral danger information Electric currentOperator requirements Personnel requirementsIntended use Use of the devicePrior to installation / commissioning Maintenance, service, faultsTransport Functions Processing the setpoint Thyro-SProcessing the setpoint Thyro-A Processing the setpoint Thyro-Step Controller Freely addressable digital outputsRelais Control Installation Connecting a 24 V power supplyConnecting the power controller to Connecting the Ethernet bus module to the masterSettings Setting the protocolSetting the number of slots Setting the device nameOperating display of the bus module Operating display of the bus moduleOperating status of the Ethernet bus module Status LED of the Ethernet PortsStart configuration parameterization Cyclical data transmission configurationOperation Input and output data Thyro-STab b Thyro-S Faults Tab Interpretation of the master setpoint with Thyro-STab Cyclic input and output data with Thyro-S ..H1 Tab Cyclic input and output data with Thyro-S ..HRL1Input and output data Thyro-A Tab b Thyro-S StatusTab Cyclic input and output data with Thyro-A 1A...H1 Tab Cyclic input and output data with Thyro-A 1A...HRL1Tab Cyclic input and output data with Thyro-A 1A...HRLP1 Tab Cyclic input and output data with Thyro-A 2A...H1Tab Cyclic input and output data with Thyro-A 2A...HRL1 Tab Cyclic input and output data with Thyro-A 2A...HRLP1 Tab Cyclic input and output data with Thyro-A 3A...H1Tab Cyclic input and output data with Thyro-A 3A...HRL1 Tab Cyclic input and output data with Thyro-A 3A...HRLP1Tab a Thyro-A Fault Tab b Thyro-A StatusTab Cyclic input and output data with Thyro-A 1A...C01 Tab Cyclic input and output data with Thyro-A 1A...C02Tab Cyclic input and output data with Thyro-A 1A...C03 Tab Cyclic input and output data with Thyro-A 1A...C05 Tab Cyclic input and output data with Thyro-A 1A...C07Supported operating modes TPM TSC TMU Tab Supported operating modesInput and output data Thyro-Power Manager Tab Cyclic input and output data TPM automatic modeTab Cyclic input and output data TPM manual mode Tab Cyclic input and output data TSC mode Tab Cyclic input and output data TIO modeInput and output data Thyro-Step Controller Input and output data Thyro Input/Output UnitTab Cyclic input and output data TMU mode Tab b Fault TPM, TSC, TIO, TMUInput and output data Thyro-Measurement Unit Tab b Status TPM, TSC, TIO, TMUAcyclic data transmission parameterization Read data record RdrecWrite data record Wrrec Power supply External connectionsOperating elements and terminal blocks Interfaces System interfaceEthernet interfaces Connection diagrams Thyro-A Connection diagram Thyro-AConnection diagrams Thyro-S Connection diagram Thyro-SConnection diagrams TSC Connection diagram TSCTechnical Data InstallationService Specific notesDimension drawings Accessories and optionsApprovals and conformity Detail Appendix a Controller parameterHRL1 Hrlp SST RLP1 U16 R309 Index R309 DAC1OF Page Type value U mains U16 …260 Measuring and cycle time …1500