12. Specific notes

12.1 Installation

The bus modules can be installed in any desired order.

12.2 Service

The devices supplied have been produced in accordance with the quality standard ISO 9001. Should there be faults in spite of this, our 24 hour service hotline is on hand, tel.: +49 (0)2902 763-100.

13. Technical Data

Power supply

24V DC 150mA

Connection options for

up to 8 AEG power controllers of series Thyro-S, Thyro-A and the TPM

 

series

Function control

LED

Assembly

DIN rail

Ambient temperature

maximum 55°C

Dimensions (WxDxH):

150 x 60 x 95 mm

Weight circa:

0.35 kg

33

Image 33
Contents Ethernet Bus Module ProfiNet Contents List of figures and tables Contact Introduction Identification in the operating instructions SafetyGeneral danger information Electric currentPersonnel requirements Operator requirementsIntended use Use of the devicePrior to installation / commissioning Maintenance, service, faultsTransport Functions Processing the setpoint Thyro-SProcessing the setpoint Thyro-A Processing the setpoint Thyro-Step Controller Freely addressable digital outputsRelais Control Connecting a 24 V power supply InstallationConnecting the power controller to Connecting the Ethernet bus module to the masterSetting the protocol SettingsSetting the number of slots Setting the device nameOperating display of the bus module Operating display of the bus moduleOperating status of the Ethernet bus module Status LED of the Ethernet PortsCyclical data transmission configuration Start configuration parameterizationOperation Input and output data Thyro-STab Interpretation of the master setpoint with Thyro-S Tab b Thyro-S FaultsTab Cyclic input and output data with Thyro-S ..H1 Tab Cyclic input and output data with Thyro-S ..HRL1Tab b Thyro-S Status Input and output data Thyro-ATab Cyclic input and output data with Thyro-A 1A...H1 Tab Cyclic input and output data with Thyro-A 1A...HRL1Tab Cyclic input and output data with Thyro-A 1A...HRLP1 Tab Cyclic input and output data with Thyro-A 2A...H1Tab Cyclic input and output data with Thyro-A 2A...HRL1 Tab Cyclic input and output data with Thyro-A 3A...H1 Tab Cyclic input and output data with Thyro-A 2A...HRLP1Tab Cyclic input and output data with Thyro-A 3A...HRLP1 Tab Cyclic input and output data with Thyro-A 3A...HRL1Tab b Thyro-A Status Tab a Thyro-A FaultTab Cyclic input and output data with Thyro-A 1A...C01 Tab Cyclic input and output data with Thyro-A 1A...C02Tab Cyclic input and output data with Thyro-A 1A...C03 Tab Cyclic input and output data with Thyro-A 1A...C07 Tab Cyclic input and output data with Thyro-A 1A...C05Supported operating modes TPM TSC TMU Tab Supported operating modesInput and output data Thyro-Power Manager Tab Cyclic input and output data TPM automatic modeTab Cyclic input and output data TPM manual mode Tab Cyclic input and output data TIO mode Tab Cyclic input and output data TSC modeInput and output data Thyro-Step Controller Input and output data Thyro Input/Output UnitTab b Fault TPM, TSC, TIO, TMU Tab Cyclic input and output data TMU modeInput and output data Thyro-Measurement Unit Tab b Status TPM, TSC, TIO, TMUAcyclic data transmission parameterization Read data record RdrecWrite data record Wrrec External connections Power supplyOperating elements and terminal blocks Interfaces System interfaceEthernet interfaces Connection diagram Thyro-A Connection diagrams Thyro-AConnection diagram Thyro-S Connection diagrams Thyro-SConnection diagram TSC Connection diagrams TSCInstallation Technical DataService Specific notesDimension drawings Accessories and optionsApprovals and conformity Detail Controller parameter Appendix aHRL1 Hrlp SST RLP1 U16 R309 Index R309 DAC1OF Page Type value U mains U16 …260 Measuring and cycle time …1500