Front PanelLTPH-UM-1031-03, Issue 3
Table 2. Front-Panel Display Messages (Continued)
Message | Full Name | Description |
|
| |
LOOPBACK MESSAGES |
| |
CDU1 | Customer Doubler 1 Loopback | DS1 signal from customer is looped back to the customer at H4D1 |
|
| (111100). |
CDU2 | Customer Doubler 2 Loopback | DS1 signal from customer is looped back to the customer at H4D2 |
|
| (111110). |
CLOC | Customer Local Loopback | DS1 signal from customer is looped back to the customer at the |
COLB | Central Office Loopback | Dual loopback at the |
CREM | Customer Remote Loopback | DS1 signal from customer is looped back to the customer at the |
|
| |
NDU1 | Network Doubler 1 Loopback | Signal is looped back to the network at H4D1 (110000). |
NDU2 | Network Doubler 2 Loopback | Signal is looped back to the network at H4D2 (111000). |
NLOC | Network Local Loopback | |
NREM | Network Remote Loopback | |
RULB | Remote Unit Loopback | Dual loopback at the |
SMJK | Remote SmartJack Loopback | |
|
| module. |
DIAGNOSTIC MESSAGES |
| |
A=xx | Maximum Loop Attenuation | The Attenuation (A) message appears followed by xx, where xx is the |
|
| highest loop attenuation of all HDSL interfaces. |
ACQ1 or ACQ2 | Acquisition 1 or Acquisition 2 | The multiplexers of the |
|
| synchronization over HDSL4 Loop 1 or Loop 2. |
ARM | System Armed | Armed to respond to Intelligent Repeater Loop (ILR) codes. |
BAD RT? | No Response from | The |
|
| loop conditions are normal; therefore, the integrity of the |
|
| the HDSL4 loops is questionable. |
FERR | Framing Bit Error Occurred | Framing bit error occurred at |
HxES | HDSL4 CRC Error Loop 1 or Loop 2 | |
|
| error. (Loop 1 has display priority over Loop 2.) |
LBPV | Local Bipolar Violation | A bipolar violation has been received at the |
|
| |
1=xx or 2=xx | HDSL4 Loop Margin | Indicates the power of the received HDSL4 signal on each loop relative |
|
| to noise (S/N with respect to 21.5 dB). Any value of 6 dB or greater is |
|
| adequate for reliable system operation. (xx denotes lowest margin in |
|
| dB for Loop 1 and Loop 2.) |
MNGD | Managed | The |
|
| management unit. In this state, the |
|
| pushbuttons are disabled. |
PWR FEED OFF | Power Feed Off | HDSL4 span power has been turned off by setting the PWRF option to |
|
| OFF, or HDSL4 span power has been turned off by use of the A5LB |
|
| Intelligent Office Repeater (IOR) powerdown code. |
PWR FEED ON | Power Feed On | Indicates that the HDSL4 loop power is applied and neither pair is |
|
| grounded. |
SIG1 or SIG2 | Signaling | The transceivers of the |
|
| contact with each other over HDSL4 on Loop 1 or Loop 2. |
SYSTEM INFORMATION MESSAGES (a) |
| |
VER x.xx | Software Version Number | The software version number of the |
LIST xx | List Number | The list number of the |
|
|
|
|
| Continued |
6 | September 12, 2003 |