Provisioning | |
|
|
Table 5 describes the Standard Config menu options and lists their menu screen display codes. Table 6 on page 20 describes the ADC Config menu options. Selections in bold type are the factory default settings.
Table 5. H4TU-C-319 List 1 Standard Config Menu Options
Standard Config | Screen | Selection | Description | |
Menu Options | Display Code | |||
|
| |||
|
|
|
| |
Loopback Timeout | LBTO | NONE | Disables automatic | |
|
| 20 min | Sets automatic cancellation of all loopbacks to 20 minutes after initiation. | |
|
| 60 min | Sets automatic cancellation of all loopbacks to 60 minutes after initiation. | |
|
| 120 min | Sets automatic cancellation of all loopbacks to 120 minutes after initiation. | |
|
| 8 hr | Sets automatic cancellation of all loopbacks to 8 hours after initiation. | |
|
| 24 hr | Sets automatic cancellation of all loopbacks to 24 hours after initiation. | |
|
|
|
| |
Loop Attenuation | LATT | 0 through | Determines the maximum loop attenuation before an alarm is declared. Zero | |
Threshold |
| 50 dB | disables the alarm. The loop attenuation threshold cannot be set from the | |
|
|
| ||
|
| 38 dB | Default value. | |
|
|
|
| |
Margin Threshold | MARG | 0 to 15 dB | Determines the minimum allowable margin below which a system alarm can | |
|
|
| occur. Zero disables the alarm. The Margin (Alarm) threshold cannot be set | |
|
|
| from the | |
|
| 4 dB | Default value. | |
|
|
|
| |
DS1 Frame | FRMG | AUTO | Configures the HDSL4 system to operate in an | |
Formatting |
|
| detects and locks to both SF or ESF DS1 frame patterns. Line and path | |
|
|
| performance parameters are maintained and displayed. Unframed payloads | |
|
|
| cause the | |
|
| SF | Configures the HDSL4 system to search for the SF framing pattern at its DS1 | |
|
|
| input. | |
|
| ESF | Configures the HDSL4 system to search for the ESF framing pattern at its DS1 | |
|
|
| input. | |
|
| UNFR | Configures the same as AUTO except unframed payloads do not cause the | |
|
|
| ||
DS1 Line Coding | DS1 | AUTO | The | |
See “DS1 Line |
|
| code. If the | |
|
| The | ||
Coding (DS1) |
|
| ||
|
| at the | ||
Option” on page 21. |
|
| ||
|
| B8ZS code, the | ||
|
|
| ||
|
|
| B8ZS code is received at the | |
|
| B8ZS | Places both the | |
|
| AMI | Places both the | |
|
|
|
| |
EQL | 0 ft | Sets the Equalizer to | ||
See |
| 133 ft | Sets the Equalizer to | |
Equalization (EQL) |
| 266 ft | Sets the Equalizer to | |
Option.” on page 21. |
| |||
| 399 ft | Sets the Equalizer to | ||
|
| |||
|
| 533 ft | Sets the Equalizer to | |
|
|
|
| |
RLBO |
| Sets the DS1 receive level output toward the Customer Interface (CI). Line | ||
Buildout |
|
| buildout can only be set through the maintenance screens. | |
|
| 0 dB | Sets the DS1 RLBO level toward the CI to 0 dB. | |
|
| Sets the DS1 RLBO level toward the CI to | ||
|
| Sets the DS1 RLBO level toward the CI to | ||
|
|
|
| |
Alarm Pattern | ALMP | AIS | Enables the HDSL4 system to output an AIS payload at its DS1 ports for | |
See “Alarm Pattern |
|
| LOSW and LOS DS1. For priority resolution, see Figure 27 on page 45. | |
(ALMP) Option.” on |
| LOS | Enables the HDSL4 system to output an LOS condition at its DS1 ports for | |
page 22. |
|
| LOSW and LOS DS1. | |
|
|
|
| |
|
|
| Continued |
September 12, 2003 | 19 |