ADC H4TU-C-319 List 1 Line Unit H4TU-C-319 List 1 Standard Config Menu Options, 60 min, 38 dB

Page 27

LTPH-UM-1031-03, Issue 3

Provisioning

 

 

Table 5 describes the Standard Config menu options and lists their menu screen display codes. Table 6 on page 20 describes the ADC Config menu options. Selections in bold type are the factory default settings.

Table 5. H4TU-C-319 List 1 Standard Config Menu Options

Standard Config

Screen

Selection

Description

Menu Options

Display Code

 

 

 

 

 

 

Loopback Timeout

LBTO

NONE

Disables automatic time-out cancellation of all loopbacks.

 

 

20 min

Sets automatic cancellation of all loopbacks to 20 minutes after initiation.

 

 

60 min

Sets automatic cancellation of all loopbacks to 60 minutes after initiation.

 

 

120 min

Sets automatic cancellation of all loopbacks to 120 minutes after initiation.

 

 

8 hr

Sets automatic cancellation of all loopbacks to 8 hours after initiation.

 

 

24 hr

Sets automatic cancellation of all loopbacks to 24 hours after initiation.

 

 

 

 

Loop Attenuation

LATT

0 through

Determines the maximum loop attenuation before an alarm is declared. Zero

Threshold

 

50 dB

disables the alarm. The loop attenuation threshold cannot be set from the

 

 

 

front-panel pushbuttons.

 

 

38 dB

Default value.

 

 

 

 

Margin Threshold

MARG

0 to 15 dB

Determines the minimum allowable margin below which a system alarm can

 

 

 

occur. Zero disables the alarm. The Margin (Alarm) threshold cannot be set

 

 

 

from the front-panel pushbuttons.

 

 

4 dB

Default value.

 

 

 

 

DS1 Frame

FRMG

AUTO

Configures the HDSL4 system to operate in an auto-framing (AUTO) mode. It

Formatting

 

 

detects and locks to both SF or ESF DS1 frame patterns. Line and path

 

 

 

performance parameters are maintained and displayed. Unframed payloads

 

 

 

cause the ES-P and SES-P counters to increment.

 

 

SF

Configures the HDSL4 system to search for the SF framing pattern at its DS1

 

 

 

input.

 

 

ESF

Configures the HDSL4 system to search for the ESF framing pattern at its DS1

 

 

 

input.

 

 

UNFR

Configures the same as AUTO except unframed payloads do not cause the

 

 

 

ES-P and SES-P counters to increment.

DS1 Line Coding

DS1

AUTO

The H4TU-C and H4TU-R monitor the incoming DS1 bit streams for the B8ZS

See “DS1 Line

 

 

code. If the H4TU-R detects this code, the H4TU-C enters B8ZS output mode.

 

 

The H4TU-C reverts back to AMI output mode if no B8ZS codes are received

Coding (DS1)

 

 

 

 

at the H4TU-R input for 5 seconds. Similarly, when the H4TU-C detects the

Option” on page 21.

 

 

 

 

B8ZS code, the H4TU-R enters the B8ZS mode and returns to AMI mode if no

 

 

 

 

 

 

B8ZS code is received at the H4TU-C input for 5 seconds.

 

 

B8ZS

Places both the H4TU-C and H4TU-R into their B8ZS modes.

 

 

AMI

Places both the H4TU-C and H4TU-R into their AMI modes.

 

 

 

 

H4TU-C Equalization

EQL

0 ft

Sets the Equalizer to DSX-1 for 0 to 132 feet.

See “H4TU-C

 

133 ft

Sets the Equalizer to DSX-1 for 133 to 265 feet.

Equalization (EQL)

 

266 ft

Sets the Equalizer to DSX-1 for 266 to 398 feet.

Option.” on page 21.

 

 

399 ft

Sets the Equalizer to DSX-1 for 399 to 532 feet.

 

 

 

 

533 ft

Sets the Equalizer to DSX-1 for 533 to 655 feet.

 

 

 

 

H4TU-R Line

RLBO

 

Sets the DS1 receive level output toward the Customer Interface (CI). Line

Buildout

 

 

buildout can only be set through the maintenance screens.

 

 

0 dB

Sets the DS1 RLBO level toward the CI to 0 dB.

 

 

-7.5 dB

Sets the DS1 RLBO level toward the CI to -7.5 dB.

 

 

-15 dB

Sets the DS1 RLBO level toward the CI to -15.0 dB.

 

 

 

 

Alarm Pattern

ALMP

AIS

Enables the HDSL4 system to output an AIS payload at its DS1 ports for

See “Alarm Pattern

 

 

LOSW and LOS DS1. For priority resolution, see Figure 27 on page 45.

(ALMP) Option.” on

 

LOS

Enables the HDSL4 system to output an LOS condition at its DS1 ports for

page 22.

 

 

LOSW and LOS DS1.

 

 

 

 

 

 

 

Continued

H4TU-C-319 List 1

September 12, 2003

19

Image 27
Contents H4TU-C-319 List 1 Line Unit HDSL4September 12 IssueDate Revisions Made 2001 Initial release March 15Inspecting Shipment Using this ManualInspecting Shipment Table of Contents Appendix B Functional Operation List of Figures Config MenuList of Tables Navigational Keys for the Maintenance Terminal ScreensOverview FeaturesApplications H4TU-C-319 List 1 Front Panel Front PanelLine Front-Panel Feature FunctionFront-Panel Description BRGMessage Full Name Description Front-Panel Display MessagesDiagnostic Messages Loopback MessagesSystem Information Messages a Substitution B8ZS Marg Margin Current margin threshold setting measured in dBFRM Frame SF, ESF, Unfr Code Line Code AMI, B8ZSInstalling the H4TU-C-319 List 1 into a Shelf InstallationVerification Verification without a Downstream DeviceVerification with a Downstream Device Using the Mode and SEL Pushbuttons Setting Options through Mode and SELProvisioning Loopback Modes Resetting to Factory DefaultDisplaying System Parameter Settings Disabling an AlarmLogon Screen Using a Maintenance TerminalConnecting to a Maintenance Terminal Navigational Keys for the Maintenance Terminal ScreensMenu Functions Press this keyPress this key To access this menu Menu Functions Provisioning Tasks Setting Date and TimeInventory Screen Setting Circuit ID NumbersConfig Menu Configuring the SystemConfig Menu Standard Options defaults shown Auto H4TU-C-319 List 1 Standard Config Menu Options60 min 38 dBDEF H4TU-C-319 List 1 ADC Config Menu OptionsADC Config Menu Screen Selection Description Options DISALM ENA HDSL4 BER HberNone LpbkParameter DS1/DSX-1 24-Hour PM ThresholdResetting to Factory Defaults Config Menu Master Clear Clearing the History, Alarm, and Event Log ScreensUsing the Monitor Screen to View System Activity Monitoring System Activity and PerformanceSystem Overview Monitor Screen Descriptions Field DescriptionMAL Insl LPFPRM Performance History at the DS1 Interface Using the Performance Screens to View Performance DataH4TU-C DS1 25-Hour Performance History H4TU-R DS1 Current Statistics Acronym Description Acronyms Used on the DS1 Performance History ScreensH4TU-C Hdsl Loop 1/Loop 2 31-Day Performance History Performance History at the HDSL4 InterfaceH4TU-C Hdsl Loop 1/Loop 2 25-Hour Performance History Losws Acronyms Used on the HDSL4 Performance History ScreensSES UASAlarm History at the DS1 Interface Using the Performance Screens to View Alarm DataPRM-NE Prmn Screen Alarm Front-PanelDescription H4TU-C DS1 Alarms onH4TU-R DS1 Alarms on this RAI RraiHDSL4 Alarms at the H4TU-C only Alarm History at the HDSL4 InterfaceSystem Event Log Using the Event LOG to Track System EventsEvent Log Entry Messages List Event Log MessagesPRM-FE Report Menu Full Report Using the Report MenuType Contains the following information Report TypesFront-Panel Alarm Description To Inhibit Message a TestingSystem Alarms Front-Panel System AlarmsPrmn Front-Panel Alarm DescriptionRetiring System Alarms Alarm Option for DLC FeedRemote LOS and AIS Response OCT55 Test Pattern with AMI Line CodeLoopback Summary Loopback OperationSpecial Loopback Commands Generic Loopback CommandsManual Loopback Session Setting the Loopback Time-Out Option LbtoGeneral Troubleshooting Tips Loopback Test ProceduresLoopback Modes MODE/SEL Gnlb Test ProceduresSummary of HDSL4 Loopback and Activation Codes Loopback Code Description Test Set Craft PortA3LB Test Procedure A3LB Addressable Repeater Loopback CommandsName A5LB Addressable Repeater Loopback Commands A5LB Test ProcedureTesting LTPH-UM-1031-03, Issue Option Description Testing with H4TU-C Bert GeneratorBert Signal Generator Bert Signal PatternH4TU-R Bert Generator Screen Testing with H4TU-R Bert GeneratorHDSL4 Appendix a SpecificationsOne-way DS1 Delay 700 µs Wander Looped SystemWideband Jitter Looped UI maximum Narrowband Jitter Looped Power Consumption Maximum Power DissipationH4TU-C Power Parameters 196 KHz dB/kft HDSL4 Reach ChartMaximum Current Drain Loop ATTENUATION, Insertion LOSS, and ReachNetwork Management Control Bus Fuse AlarmCraft Port System Alarm Output PinTiming Ground Fault DetectionSpectrum Issues Appendix B Functional OperationAppendix C Compatibility Online Technical Support Online Technical Publications Appendix D Product SupportSales Assistance Systems IntegrationAppendix E Abbreviations Lbto LaisLatt LbpvLTPH-UM-1031-03, Issue FCC Class a Compliance Limited Warranty Certification and WarrantyFor Technical Assistance World Headquarters