ADC HDSL4 user manual A3LB Test Procedure, A3LB Addressable Repeater Loopback Commands, Name

Page 60

Testing

LTPH-UM-1031-03, Issue 3

 

 

To perform the GNLB loopback test procedure:

1Have the CO tester send the NREM (3-in-7) inband loopup code for 5 seconds. You should observe the NREM message on the front-panel display. (The Status LED on the front panel should be green, and the loopback mode should also be identified on the Monitor screen.)

2Have the CO tester transmit a DS1 test signal towards the H4TU-C and verify that the returned (looped) signal to the test set is error-free.

3If step 2 fails, have the CO tester transmit the (3-in-5) inband loopdown code.

4Have the CO tester send the NLOC (4-in-7) inband loopup for 5 seconds. You should observe the NLOC message on the front-panel display. (The Status LED on the front panel should be yellow, and the loopback mode should also be identified on the Monitor screen.)

5Repeat Step 2. If the test passes, the problem is in the downstream direction. If it fails, the problem is in the upstream direction.

A3LB Test Procedure

The H4TU-C-319 can be looped back by sending the Addressable Office Repeater (AOR) LPBK activation code 1111-1111-0001-1110 (FF1E) for at least 5 seconds. This causes the H4TU-C to enter the NLOC state. The Loopback Time-Out setting (see “Setting the Loopback Time-Out Option (LBTO)” on page 48) determines the duration of this loopback unless it is overridden by the reception of a second identical 16-bit loopup command before the timer expires. When this time-out override state exists, the only way to loop the H4TU-C down is to issue one of the three loopdown commands listed in Table 17. The automatic time-out mode is restored during subsequent loopback sessions.

Table 17 summarizes the codes required to execute an A3LB Addressable Repeater Loopback command. All code sequences must be present for at least 5 seconds.

Table 17. A3LB Addressable Repeater Loopback Commands

Name

Binary Code (a) (Hexadecimal Equivalent)

Description

NLOC

1111-1111-0001-1110 (FF1E)

H4TU-C loopup from NI.

 

 

 

CREM

0011-1111-0001-1110 (3F1E)

H4TU-C loopup from CI.

 

 

 

NREM

1111-1111-0000-0010 (FF02)

H4TU-R loopup from NI.

 

 

 

NDU1

1111-1111-0000-0100 (FF04)

Signal is looped back to the network at H4D1.

 

 

 

CDU1

0011-1111-0000-0100 (3F04)

DS1 signal from customer is looped back to the customer at H4D1.

 

 

 

NDU2

1111-1111-0000-0110 (FF06)

Signal is looped back to the network at H4D2.

 

 

 

CDU2

0011-1111-0000-0110 (3F06)

DS1 signal from customer is looped back tot he customer at H4D2.

 

 

 

D1LB

 

Dual loopback at H4D1.

 

 

 

D2LB

 

Dual loopback at H4D2.

 

 

 

CLOC

0011-1111-0000-0010 (3F02)

H4TU-R loopup from CI.

 

 

 

SMJK

11000-11000-11000 ...

H4TU-R loopup from NI.

 

 

 

SMJK

100000 100000 100000 ...

H4TU-R loopup from NI.

 

 

 

SMJK

1111-1111-0100-1000 (FF48)

H4TU-R loopup from NI (ESF-DL).

 

 

 

Loopdown

11100-11100-11100 ...

H4TU-C and H4TU-R loopdown from NI OR CI.

 

 

 

Loopdown

100-100-100 ...

H4TU-C and H4TU-R loopdown from NI OR CI.

 

 

 

Loopdown

1111-1111-0010-0100 (FF24)

H4TU-C and H4TU-R loopdown from NI OR CI (ESF-DL).

 

 

 

(a)The leftmost bit arrives first in all sequences. The detection algorithm functions reliably with a random 10-3Bit Error Ratio (BER) on the facility. The entire arming and loopback sequence can also be initiated at the remote H4TU-R location.

52

September 12, 2003

H4TU-C-319 List 1

Image 60
Contents HDSL4 H4TU-C-319 List 1 Line UnitIssue Date Revisions Made2001 Initial release March 15 September 12Using this Manual Inspecting ShipmentInspecting Shipment Table of Contents Appendix B Functional Operation Config Menu List of FiguresNavigational Keys for the Maintenance Terminal Screens List of TablesFeatures OverviewApplications Front Panel H4TU-C-319 List 1 Front PanelFront-Panel Feature Function Front-Panel DescriptionBRG LineFront-Panel Display Messages Message Full Name DescriptionDiagnostic Messages Loopback MessagesSystem Information Messages a Marg Margin Current margin threshold setting measured in dB FRM Frame SF, ESF, UnfrCode Line Code AMI, B8ZS Substitution B8ZSInstallation Installing the H4TU-C-319 List 1 into a ShelfVerification Verification without a Downstream DeviceVerification with a Downstream Device Using the Mode and SEL Pushbuttons Setting Options through Mode and SELProvisioning Resetting to Factory Default Displaying System Parameter SettingsDisabling an Alarm Loopback ModesUsing a Maintenance Terminal Connecting to a Maintenance TerminalNavigational Keys for the Maintenance Terminal Screens Logon ScreenPress this key Menu FunctionsPress this key To access this menu Menu Functions Setting Date and Time Provisioning TasksSetting Circuit ID Numbers Inventory ScreenConfiguring the System Config MenuConfig Menu Standard Options defaults shown H4TU-C-319 List 1 Standard Config Menu Options 60 min38 dB AutoH4TU-C-319 List 1 ADC Config Menu Options ADC Config Menu Screen Selection Description OptionsDIS DEFHDSL4 BER Hber NoneLpbk ALM ENADS1/DSX-1 24-Hour PM Threshold ParameterResetting to Factory Defaults Clearing the History, Alarm, and Event Log Screens Config Menu Master ClearUsing the Monitor Screen to View System Activity Monitoring System Activity and PerformanceSystem Overview Monitor Screen Descriptions Field DescriptionMAL Insl LPFPRM Using the Performance Screens to View Performance Data Performance History at the DS1 InterfaceH4TU-C DS1 25-Hour Performance History H4TU-R DS1 Current Statistics Acronyms Used on the DS1 Performance History Screens Acronym DescriptionPerformance History at the HDSL4 Interface H4TU-C Hdsl Loop 1/Loop 2 31-Day Performance HistoryH4TU-C Hdsl Loop 1/Loop 2 25-Hour Performance History Acronyms Used on the HDSL4 Performance History Screens SESUAS LoswsUsing the Performance Screens to View Alarm Data Alarm History at the DS1 InterfaceScreen Alarm Front-PanelDescription H4TU-C DS1 Alarms on H4TU-R DS1 Alarms on thisRAI Rrai PRM-NE PrmnAlarm History at the HDSL4 Interface HDSL4 Alarms at the H4TU-C onlyUsing the Event LOG to Track System Events System Event LogEvent Log Entry Messages List Event Log MessagesPRM-FE Using the Report Menu Report Menu Full ReportReport Types Type Contains the following informationTesting System AlarmsFront-Panel System Alarms Front-Panel Alarm Description To Inhibit Message aFront-Panel Alarm Description PrmnAlarm Option for DLC Feed Retiring System AlarmsOCT55 Test Pattern with AMI Line Code Remote LOS and AIS ResponseLoopback Operation Loopback SummaryGeneric Loopback Commands Special Loopback CommandsSetting the Loopback Time-Out Option Lbto Manual Loopback SessionLoopback Test Procedures General Troubleshooting TipsLoopback Modes Gnlb Test Procedures Summary of HDSL4 Loopback and Activation CodesLoopback Code Description Test Set Craft Port MODE/SELA3LB Test Procedure A3LB Addressable Repeater Loopback CommandsName A5LB Test Procedure A5LB Addressable Repeater Loopback CommandsTesting LTPH-UM-1031-03, Issue Testing with H4TU-C Bert Generator Bert Signal GeneratorBert Signal Pattern Option DescriptionTesting with H4TU-R Bert Generator H4TU-R Bert Generator ScreenAppendix a Specifications HDSL4One-way DS1 Delay 700 µs Wander Looped SystemWideband Jitter Looped UI maximum Narrowband Jitter Looped Power Consumption Maximum Power DissipationH4TU-C Power Parameters HDSL4 Reach Chart Maximum Current DrainLoop ATTENUATION, Insertion LOSS, and Reach 196 KHz dB/kftFuse Alarm Network Management Control BusSystem Alarm Output Pin Craft PortGround Fault Detection Spectrum IssuesAppendix B Functional Operation TimingAppendix C Compatibility Appendix D Product Support Sales AssistanceSystems Integration Online Technical Support Online Technical PublicationsAppendix E Abbreviations Lais LattLbpv LbtoLTPH-UM-1031-03, Issue Certification and Warranty FCC Class a Compliance Limited WarrantyWorld Headquarters For Technical Assistance