ADC HDSL4, H4TU-C-319 List 1 Line Unit user manual Network Management Control Bus, Fuse Alarm

Page 70

Appendix A - Specifications

LTPH-UM-1031-03, Issue 3

 

 

H4TU-C-319 CARD-EDGECONNECTOR

Figure 32 shows the card-edge connectors on the H4TU-C-319. Active pins are highlighted in black.

(IN) DSX-1Tip

 

 

 

A

 

 

 

 

 

1

 

 

 

DSX-1 Ring (IN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(OUT) DSX-1Tip 1

 

B

 

 

2

 

 

 

DSX-1 Ring 1 (OUT)

 

 

 

 

 

 

 

 

C

 

 

3

 

 

 

 

 

 

 

 

D

 

 

4

 

 

 

 

 

 

 

 

E

 

 

5

GND

HDSL4 - L1Tip F

 

 

6

HDSL4 - L1 Ring

System Alarm**

H

 

 

7

Management Bus**

Frame GND

J

 

 

8

-48 Vdc

HDSL4 - L2Tip

K

 

 

9

HDSL4 - L2 Ring

(Do not use)

L

 

 

 

10

Fuse Alarm*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Fuse Alarm

Normal = Floating (0 to -60 Vdc maximum)

Activated = -48 Vdc (10 mA maximum)

**System Alarm and Management Bus (reserved)

Figure 32. H4TU-C-319 Card-Edge Connector

Network Management Control Bus

The H4TU-C provides a Network Management Control Bus on pin 7 of the card-edge connector. This allows the various Management System protocols to manage the H4TU-C through the HMU-319. Whenever the H4TU-C is under management, the MNGD message displays periodically on the front-panel display.

Some H4TU-C-319 features are affected when it is under management. Consult the management unit practice for further information (see “Appendix D - Product Support” on page 66).

Fuse Alarm

Pin 10 on the card-edge connector is a Fuse Alarm that is driven to -48 Vdc whenever its onboard fuse opens. It emulates the function of the Fuse Alarm output from pin 10 on normal, high-density (HD) repeaters. Pin 10 is connected to pin 5 of the 1184 Alarm Card (slot 1 in the HD shelf) and causes the 1184 Fuse ALM LED to light when the pin 10 signal is activated. Its normally floating output must never be driven above ground or below -80 V. It can sink a current of 10 mA. The H4TU-C does not support the BPV function (Pin E) of normal HD repeaters.

62

September 12, 2003

H4TU-C-319 List 1

Image 70
Contents HDSL4 H4TU-C-319 List 1 Line Unit2001 Initial release March 15 IssueDate Revisions Made September 12Using this Manual Inspecting ShipmentInspecting Shipment Table of Contents Appendix B Functional Operation Config Menu List of FiguresNavigational Keys for the Maintenance Terminal Screens List of TablesFeatures OverviewApplications Front Panel H4TU-C-319 List 1 Front PanelBRG Front-Panel Feature FunctionFront-Panel Description LineFront-Panel Display Messages Message Full Name DescriptionLoopback Messages Diagnostic MessagesSystem Information Messages a Code Line Code AMI, B8ZS Marg Margin Current margin threshold setting measured in dBFRM Frame SF, ESF, Unfr Substitution B8ZSInstallation Installing the H4TU-C-319 List 1 into a ShelfVerification without a Downstream Device VerificationVerification with a Downstream Device Setting Options through Mode and SEL Using the Mode and SEL PushbuttonsProvisioning Disabling an Alarm Resetting to Factory DefaultDisplaying System Parameter Settings Loopback ModesNavigational Keys for the Maintenance Terminal Screens Using a Maintenance TerminalConnecting to a Maintenance Terminal Logon ScreenPress this key Menu FunctionsPress this key To access this menu Menu Functions Setting Date and Time Provisioning TasksSetting Circuit ID Numbers Inventory ScreenConfiguring the System Config MenuConfig Menu Standard Options defaults shown 38 dB H4TU-C-319 List 1 Standard Config Menu Options60 min AutoDIS H4TU-C-319 List 1 ADC Config Menu OptionsADC Config Menu Screen Selection Description Options DEFLpbk HDSL4 BER HberNone ALM ENADS1/DSX-1 24-Hour PM Threshold ParameterResetting to Factory Defaults Clearing the History, Alarm, and Event Log Screens Config Menu Master ClearMonitoring System Activity and Performance Using the Monitor Screen to View System ActivitySystem Overview Field Description Monitor Screen DescriptionsMAL LPF InslPRM Using the Performance Screens to View Performance Data Performance History at the DS1 InterfaceH4TU-C DS1 25-Hour Performance History H4TU-R DS1 Current Statistics Acronyms Used on the DS1 Performance History Screens Acronym DescriptionPerformance History at the HDSL4 Interface H4TU-C Hdsl Loop 1/Loop 2 31-Day Performance HistoryH4TU-C Hdsl Loop 1/Loop 2 25-Hour Performance History UAS Acronyms Used on the HDSL4 Performance History ScreensSES LoswsUsing the Performance Screens to View Alarm Data Alarm History at the DS1 InterfaceRAI Rrai Screen Alarm Front-PanelDescription H4TU-C DS1 Alarms onH4TU-R DS1 Alarms on this PRM-NE PrmnAlarm History at the HDSL4 Interface HDSL4 Alarms at the H4TU-C onlyUsing the Event LOG to Track System Events System Event LogEvent Log Messages Event Log Entry Messages ListPRM-FE Using the Report Menu Report Menu Full ReportReport Types Type Contains the following informationFront-Panel System Alarms TestingSystem Alarms Front-Panel Alarm Description To Inhibit Message aFront-Panel Alarm Description PrmnAlarm Option for DLC Feed Retiring System AlarmsOCT55 Test Pattern with AMI Line Code Remote LOS and AIS ResponseLoopback Operation Loopback SummaryGeneric Loopback Commands Special Loopback CommandsSetting the Loopback Time-Out Option Lbto Manual Loopback SessionLoopback Test Procedures General Troubleshooting TipsLoopback Modes Loopback Code Description Test Set Craft Port Gnlb Test ProceduresSummary of HDSL4 Loopback and Activation Codes MODE/SELA3LB Addressable Repeater Loopback Commands A3LB Test ProcedureName A5LB Test Procedure A5LB Addressable Repeater Loopback CommandsTesting LTPH-UM-1031-03, Issue Bert Signal Pattern Testing with H4TU-C Bert GeneratorBert Signal Generator Option DescriptionTesting with H4TU-R Bert Generator H4TU-R Bert Generator ScreenAppendix a Specifications HDSL4System One-way DS1 Delay 700 µs Wander LoopedWideband Jitter Looped UI maximum Narrowband Jitter Looped Maximum Power Dissipation Power ConsumptionH4TU-C Power Parameters Loop ATTENUATION, Insertion LOSS, and Reach HDSL4 Reach ChartMaximum Current Drain 196 KHz dB/kftFuse Alarm Network Management Control BusSystem Alarm Output Pin Craft PortAppendix B Functional Operation Ground Fault DetectionSpectrum Issues TimingAppendix C Compatibility Systems Integration Appendix D Product SupportSales Assistance Online Technical Support Online Technical PublicationsAppendix E Abbreviations Lbpv LaisLatt LbtoLTPH-UM-1031-03, Issue Certification and Warranty FCC Class a Compliance Limited WarrantyWorld Headquarters For Technical Assistance