ADC H4TU-C-319 List 1 Line Unit, HDSL4 Acronyms Used on the DS1 Performance History Screens

Page 39

LTPH-UM-1031-03, Issue 3Monitoring System Activity and Performance

Table 9. Acronyms Used on the DS1 Performance History Screens

Acronym

Description

Acronym

Description

 

 

 

 

 

CV-L

Code Violation - Line

SES-P

Severely Errored Seconds - Path

 

Total BPV count.

 

Seconds with SES or CRC(ESF) 320 or

 

 

 

FE (a)(SF) 8 (F

+ F ).

 

 

 

T

S

ES-L (b)

Errored Seconds - Line

UAS-P

Unavailable Seconds - Path

 

Seconds with BPV 1.

 

A second of unavailability based on SES-P or

 

 

 

AIS 1.

 

 

 

 

 

SES-L

Severely Errored Seconds - Line

PRM-NE (c)

Performance Report Messaging - Near End

 

Seconds with BPV plus EXZ 1544 or LOS 1.

 

The PRM from CPE indicates errors, and the

 

 

 

signal received from the network at the

 

 

 

remote is error-free.

UAS-L

Unavailable Seconds - Line

PRM-FE (c)

Performance Report Messaging - Far End

 

Seconds with LOS 1.

 

The PRM from the network indicates errors,

 

 

 

and the signal received from the CPE is

 

 

 

error-free.

 

CV-P

Code Violation - Path

B8ZSS (d)

B8ZS Errored Seconds

 

Total count of SF frame bit (FB) errors or

 

Seconds with B8ZS detection when AMI

 

CRC(ESF) errors.

 

option is active.

 

ES-P (e)

Errored Seconds - Path

MSEC (d)

Monitored Seconds of the current

 

Seconds with SEF (f), CRC (ESF), or

 

(15-minute/1-hour/1-day) screen.

 

FE (a)(SF) 1.

 

 

 

(a)FE is a frame bit error.

(b)Line (L) refers to the AMI DS1 line used to transport the payload.

(c)Only displays on H4TU-R Performance History screens.

(d)Displays on the DS1 Current Statistics screens.

(e)Path (P) refers to the total framed payload being transported between two points.

(f)Severely Errored Frame–Two or more frame bit errors occurring in a 0.75 ms interval for SF or a 3 ms interval for ESF.

H4TU-C-319 List 1

September 12, 2003

31

Image 39
Contents H4TU-C-319 List 1 Line Unit HDSL4September 12 IssueDate Revisions Made 2001 Initial release March 15Inspecting Shipment Using this ManualInspecting Shipment Table of Contents Appendix B Functional Operation List of Figures Config MenuList of Tables Navigational Keys for the Maintenance Terminal ScreensOverview FeaturesApplications H4TU-C-319 List 1 Front Panel Front PanelLine Front-Panel Feature FunctionFront-Panel Description BRGMessage Full Name Description Front-Panel Display MessagesDiagnostic Messages Loopback MessagesSystem Information Messages a Substitution B8ZS Marg Margin Current margin threshold setting measured in dBFRM Frame SF, ESF, Unfr Code Line Code AMI, B8ZSInstalling the H4TU-C-319 List 1 into a Shelf InstallationVerification Verification without a Downstream DeviceVerification with a Downstream Device Using the Mode and SEL Pushbuttons Setting Options through Mode and SELProvisioning Loopback Modes Resetting to Factory DefaultDisplaying System Parameter Settings Disabling an AlarmLogon Screen Using a Maintenance TerminalConnecting to a Maintenance Terminal Navigational Keys for the Maintenance Terminal ScreensMenu Functions Press this keyPress this key To access this menu Menu Functions Provisioning Tasks Setting Date and TimeInventory Screen Setting Circuit ID NumbersConfig Menu Configuring the SystemConfig Menu Standard Options defaults shown Auto H4TU-C-319 List 1 Standard Config Menu Options60 min 38 dBDEF H4TU-C-319 List 1 ADC Config Menu OptionsADC Config Menu Screen Selection Description Options DISALM ENA HDSL4 BER HberNone LpbkParameter DS1/DSX-1 24-Hour PM ThresholdResetting to Factory Defaults Config Menu Master Clear Clearing the History, Alarm, and Event Log ScreensUsing the Monitor Screen to View System Activity Monitoring System Activity and PerformanceSystem Overview Monitor Screen Descriptions Field DescriptionMAL Insl LPFPRM Performance History at the DS1 Interface Using the Performance Screens to View Performance DataH4TU-C DS1 25-Hour Performance History H4TU-R DS1 Current Statistics Acronym Description Acronyms Used on the DS1 Performance History ScreensH4TU-C Hdsl Loop 1/Loop 2 31-Day Performance History Performance History at the HDSL4 InterfaceH4TU-C Hdsl Loop 1/Loop 2 25-Hour Performance History Losws Acronyms Used on the HDSL4 Performance History ScreensSES UASAlarm History at the DS1 Interface Using the Performance Screens to View Alarm DataPRM-NE Prmn Screen Alarm Front-PanelDescription H4TU-C DS1 Alarms onH4TU-R DS1 Alarms on this RAI RraiHDSL4 Alarms at the H4TU-C only Alarm History at the HDSL4 InterfaceSystem Event Log Using the Event LOG to Track System EventsEvent Log Entry Messages List Event Log MessagesPRM-FE Report Menu Full Report Using the Report MenuType Contains the following information Report TypesFront-Panel Alarm Description To Inhibit Message a TestingSystem Alarms Front-Panel System AlarmsPrmn Front-Panel Alarm DescriptionRetiring System Alarms Alarm Option for DLC FeedRemote LOS and AIS Response OCT55 Test Pattern with AMI Line CodeLoopback Summary Loopback OperationSpecial Loopback Commands Generic Loopback CommandsManual Loopback Session Setting the Loopback Time-Out Option LbtoGeneral Troubleshooting Tips Loopback Test ProceduresLoopback Modes MODE/SEL Gnlb Test ProceduresSummary of HDSL4 Loopback and Activation Codes Loopback Code Description Test Set Craft PortA3LB Test Procedure A3LB Addressable Repeater Loopback CommandsName A5LB Addressable Repeater Loopback Commands A5LB Test ProcedureTesting LTPH-UM-1031-03, Issue Option Description Testing with H4TU-C Bert GeneratorBert Signal Generator Bert Signal PatternH4TU-R Bert Generator Screen Testing with H4TU-R Bert GeneratorHDSL4 Appendix a SpecificationsOne-way DS1 Delay 700 µs Wander Looped SystemWideband Jitter Looped UI maximum Narrowband Jitter Looped Power Consumption Maximum Power DissipationH4TU-C Power Parameters 196 KHz dB/kft HDSL4 Reach ChartMaximum Current Drain Loop ATTENUATION, Insertion LOSS, and ReachNetwork Management Control Bus Fuse AlarmCraft Port System Alarm Output PinTiming Ground Fault DetectionSpectrum Issues Appendix B Functional OperationAppendix C Compatibility Online Technical Support Online Technical Publications Appendix D Product SupportSales Assistance Systems IntegrationAppendix E Abbreviations Lbto LaisLatt LbpvLTPH-UM-1031-03, Issue FCC Class a Compliance Limited Warranty Certification and WarrantyFor Technical Assistance World Headquarters