Testing | |
|
|
TESTING WITH H4TU-C BERT GENERATOR
The
It is not recommended using the Bit Error Rate Tester from the remote and line unit at the same time.
1Press C to select the Config menu (Figure 30).
2Use the ↑ and ↓ arrow keys to select BERT Generator, then press ENTER .
3Use the arrow keys to select an option and press the SPACEBAR to cycle through the settings. Refer to Table 19 for a list of BERT generator option settings.
4Press ENTER to activate your choice.
5To view BERT status, press ESC twice, then use the ← arrow key to select the Monitor menu.
6Press ENTER . You can exit the status screen while signal generation is active.
Monitor | Performance Event Log | Config | Inventory | Report Rlogon | Help | |||
|
|
| + |
| ||||
|
| Standard Options |
|
| ||||
|
| ADC Options |
|
| ||||
|
| BERT Generator |
|
|
|
| + | ||
BERT Signal Generator | : | ENA |
| |
BERT Signal Pattern | : | 1 in 8 | ||
BERT Signal Linecode | : AMI | |||
BERT Signal Direction | : NET only | |||
BERT Interval | : Continuous | |||
|
| + |
Use <Spacebar> to cycle through option settings and | <Enter> to activate |
| |||||
ID: | 02/01/2002 12:30:01 | System: | OK___ | ||||
| Figure 30. |
|
|
| |||
| Table 19. BERT Signal Generator Option Settings |
|
|
| |||
|
|
|
|
|
|
| |
| Option | Description |
|
|
|
| |
|
|
|
|
|
|
| |
| BERT Signal Generator | Enabled (ENA) or Disabled (DIS) |
|
|
|
| |
| BERT Signal Pattern | ||||||
|
|
|
|
| |||
| BERT Signal Linecode | AMI or B8ZS |
|
|
|
| |
| BERT Signal Direction | Toward CPE or toward NET |
|
|
|
| |
| BERT Interval | 5 minutes, 60 minutes, Continuous (default) |
|
|
| ||
|
|
|
|
|
|
|
|
56 | September 12, 2003 |