ADC HDSL4, H4TU-C-319 List 1 Line Unit Press this key To access this menu Menu Functions

Page 22

ProvisioningLTPH-UM-1031-03, Issue 3

Table 4. Logon Screen Menus (Continued)

Press this key:

To access this menu:

Menu Functions

 

 

 

R

Rlogon / Rlogout

Remote logon can be performed from the H4TU-C or the H4TU-R. The

 

 

screen displays “Rlogout” when the H4TU-C or H4TU-R is remotely

 

 

logged on to the other unit at the end of the circuit.

 

 

Remote logon from the H4TU-C will permit viewing of the H4TU-R BERT

 

 

Generator configuration submenu.

 

 

To log off the remote unit, press R . “Rlogout” changes to “Rlogon.” The

 

 

unit is now locally logged on until R is pressed again to reinitiate a

 

 

remote logon.

H

Help

Provides a glossary of terms used in the maintenance screens, a list of

 

 

navigational keys, print guide, and ADC contact information.

 

 

 

14

September 12, 2003

H4TU-C-319 List 1

Image 22
Contents HDSL4 H4TU-C-319 List 1 Line Unit2001 Initial release March 15 IssueDate Revisions Made September 12Using this Manual Inspecting ShipmentInspecting Shipment Table of Contents Appendix B Functional Operation Config Menu List of FiguresNavigational Keys for the Maintenance Terminal Screens List of TablesFeatures OverviewApplications Front Panel H4TU-C-319 List 1 Front PanelBRG Front-Panel Feature FunctionFront-Panel Description LineFront-Panel Display Messages Message Full Name DescriptionLoopback Messages Diagnostic MessagesSystem Information Messages a Code Line Code AMI, B8ZS Marg Margin Current margin threshold setting measured in dBFRM Frame SF, ESF, Unfr Substitution B8ZSInstallation Installing the H4TU-C-319 List 1 into a ShelfVerification without a Downstream Device VerificationVerification with a Downstream Device Setting Options through Mode and SEL Using the Mode and SEL PushbuttonsProvisioning Disabling an Alarm Resetting to Factory DefaultDisplaying System Parameter Settings Loopback ModesNavigational Keys for the Maintenance Terminal Screens Using a Maintenance TerminalConnecting to a Maintenance Terminal Logon ScreenPress this key Menu FunctionsPress this key To access this menu Menu Functions Setting Date and Time Provisioning TasksSetting Circuit ID Numbers Inventory ScreenConfiguring the System Config MenuConfig Menu Standard Options defaults shown 38 dB H4TU-C-319 List 1 Standard Config Menu Options60 min AutoDIS H4TU-C-319 List 1 ADC Config Menu OptionsADC Config Menu Screen Selection Description Options DEFLpbk HDSL4 BER HberNone ALM ENADS1/DSX-1 24-Hour PM Threshold ParameterResetting to Factory Defaults Clearing the History, Alarm, and Event Log Screens Config Menu Master ClearMonitoring System Activity and Performance Using the Monitor Screen to View System ActivitySystem Overview Field Description Monitor Screen DescriptionsMAL LPF InslPRM Using the Performance Screens to View Performance Data Performance History at the DS1 InterfaceH4TU-C DS1 25-Hour Performance History H4TU-R DS1 Current Statistics Acronyms Used on the DS1 Performance History Screens Acronym DescriptionPerformance History at the HDSL4 Interface H4TU-C Hdsl Loop 1/Loop 2 31-Day Performance HistoryH4TU-C Hdsl Loop 1/Loop 2 25-Hour Performance History UAS Acronyms Used on the HDSL4 Performance History ScreensSES LoswsUsing the Performance Screens to View Alarm Data Alarm History at the DS1 InterfaceRAI Rrai Screen Alarm Front-PanelDescription H4TU-C DS1 Alarms onH4TU-R DS1 Alarms on this PRM-NE PrmnAlarm History at the HDSL4 Interface HDSL4 Alarms at the H4TU-C onlyUsing the Event LOG to Track System Events System Event LogEvent Log Messages Event Log Entry Messages ListPRM-FE Using the Report Menu Report Menu Full ReportReport Types Type Contains the following informationFront-Panel System Alarms TestingSystem Alarms Front-Panel Alarm Description To Inhibit Message aFront-Panel Alarm Description PrmnAlarm Option for DLC Feed Retiring System AlarmsOCT55 Test Pattern with AMI Line Code Remote LOS and AIS ResponseLoopback Operation Loopback SummaryGeneric Loopback Commands Special Loopback CommandsSetting the Loopback Time-Out Option Lbto Manual Loopback SessionLoopback Test Procedures General Troubleshooting TipsLoopback Modes Loopback Code Description Test Set Craft Port Gnlb Test ProceduresSummary of HDSL4 Loopback and Activation Codes MODE/SELA3LB Addressable Repeater Loopback Commands A3LB Test ProcedureName A5LB Test Procedure A5LB Addressable Repeater Loopback CommandsTesting LTPH-UM-1031-03, Issue Bert Signal Pattern Testing with H4TU-C Bert GeneratorBert Signal Generator Option DescriptionTesting with H4TU-R Bert Generator H4TU-R Bert Generator ScreenAppendix a Specifications HDSL4System One-way DS1 Delay 700 µs Wander LoopedWideband Jitter Looped UI maximum Narrowband Jitter Looped Maximum Power Dissipation Power ConsumptionH4TU-C Power Parameters Loop ATTENUATION, Insertion LOSS, and Reach HDSL4 Reach ChartMaximum Current Drain 196 KHz dB/kftFuse Alarm Network Management Control BusSystem Alarm Output Pin Craft PortAppendix B Functional Operation Ground Fault DetectionSpectrum Issues TimingAppendix C Compatibility Systems Integration Appendix D Product SupportSales Assistance Online Technical Support Online Technical PublicationsAppendix E Abbreviations Lbpv LaisLatt LbtoLTPH-UM-1031-03, Issue Certification and Warranty FCC Class a Compliance Limited WarrantyWorld Headquarters For Technical Assistance