ADC HDSL4, H4TU-C-319 List 1 Line Unit user manual Testing, Front-Panel System Alarms, PWR Feed

Page 50

Testing

LTPH-UM-1031-03, Issue 3

 

 

TESTING

This section provides information about front-panel system alarms, LOS and AIS response, the OCT55 test procedure, and loopback testing.

SYSTEM ALARMS

Table 15 summarizes all possible system alarms in order of priority as they appear on the front panel. When multiple alarms occur, the front-panel display only reports the highest priority alarm. The alarm history screens display alarms also, but provide greater detail (see “Using the Performance Screens to View Performance Data” on page 28). Alarms that are not inhibited will drive the front-panel Status LED to a flashing red alarm state.

Table 15. Front-Panel System Alarms

Front-Panel

Alarm

Description

To Inhibit:

Message (a)

 

 

 

PWR FEED

Power Feed Short

A short exists between Loop 1 and Loop 2 of

Cannot be inhibited.

SHRT (b)

 

the HDSL4 pair.

 

PWR FEED

Power Feed Ground

One of the HDSL4 loops is grounded.

Cannot be inhibited.

GND (b)

 

 

 

PWR FEED

Power Feed Open

A line power open condition exists.

Cannot be inhibited.

OPEN (b)

 

 

 

SPNn-LOSW

Span(n)-Loss of Sync

The HDSL4 loop has lost synchronization.

Cannot be inhibited.

 

Word (c)

The span closest to the network has highest

 

 

 

priority.

 

 

 

 

 

LLOS

Line (Unit) Loss of

Loss of the DSX-1 input signal.

Cannot be inhibited.

 

Signal

 

 

 

 

 

 

RLOS

Remote (Unit) Loss of

Loss of the H4TU-R DS1 input signal.

Disable the RDA (Remote Disconnect

 

Signal

 

Alarm) option. This prevents an LOS

 

 

 

condition at the DS1 input to a H4TU-R

 

 

 

from activating pin H. The front-panel

 

 

 

Status LED still flashes red and the ALRM

 

 

 

RLOS message displays to alert you of the

 

 

 

LOS state. LOS is sent towards the

 

 

 

network from the H4TU-C. This option

 

 

 

prevents the common occurrences of a

 

 

 

CPE LOS condition from generating

 

 

 

recurring alarms and AIS payloads.

 

 

 

 

LAIS

Line Alarm Indication

Indicates an AIS (unframed all ones) pattern

Cannot be inhibited.

 

Signal

is being received at the H4TU-C DS1 input

 

 

 

port.

 

 

 

 

 

RAIS

Remote Alarm

Indicates an AIS (unframed all ones) pattern

Cannot be inhibited.

 

Indication Signal

is being received at the H4TU-R DS1 input

 

 

 

port.

 

 

 

 

 

LRAI

Line RAI—Remote

 

Alarm Indication at the

 

H4TU-R (Net signal

 

does not have errors.)

Indicates an RAI alarm (yellow) from the CPE Cannot be inhibited. with an error-free signal from the line unit or

network. RAI signal is transmitted towards the network.

Continued

42

September 12, 2003

H4TU-C-319 List 1

Image 50
Contents HDSL4 H4TU-C-319 List 1 Line Unit2001 Initial release March 15 IssueDate Revisions Made September 12Using this Manual Inspecting ShipmentInspecting Shipment Table of Contents Appendix B Functional Operation Config Menu List of FiguresNavigational Keys for the Maintenance Terminal Screens List of TablesFeatures OverviewApplications Front Panel H4TU-C-319 List 1 Front PanelBRG Front-Panel Feature FunctionFront-Panel Description LineFront-Panel Display Messages Message Full Name DescriptionSystem Information Messages a Diagnostic MessagesLoopback Messages Code Line Code AMI, B8ZS Marg Margin Current margin threshold setting measured in dBFRM Frame SF, ESF, Unfr Substitution B8ZSInstallation Installing the H4TU-C-319 List 1 into a ShelfVerification with a Downstream Device VerificationVerification without a Downstream Device Provisioning Using the Mode and SEL PushbuttonsSetting Options through Mode and SEL Disabling an Alarm Resetting to Factory DefaultDisplaying System Parameter Settings Loopback ModesNavigational Keys for the Maintenance Terminal Screens Using a Maintenance TerminalConnecting to a Maintenance Terminal Logon ScreenPress this key Menu FunctionsPress this key To access this menu Menu Functions Setting Date and Time Provisioning TasksSetting Circuit ID Numbers Inventory ScreenConfiguring the System Config MenuConfig Menu Standard Options defaults shown 38 dB H4TU-C-319 List 1 Standard Config Menu Options60 min AutoDIS H4TU-C-319 List 1 ADC Config Menu OptionsADC Config Menu Screen Selection Description Options DEFLpbk HDSL4 BER HberNone ALM ENADS1/DSX-1 24-Hour PM Threshold ParameterResetting to Factory Defaults Clearing the History, Alarm, and Event Log Screens Config Menu Master ClearSystem Overview Using the Monitor Screen to View System ActivityMonitoring System Activity and Performance MAL Monitor Screen DescriptionsField Description PRM InslLPF Using the Performance Screens to View Performance Data Performance History at the DS1 InterfaceH4TU-C DS1 25-Hour Performance History H4TU-R DS1 Current Statistics Acronyms Used on the DS1 Performance History Screens Acronym DescriptionPerformance History at the HDSL4 Interface H4TU-C Hdsl Loop 1/Loop 2 31-Day Performance HistoryH4TU-C Hdsl Loop 1/Loop 2 25-Hour Performance History UAS Acronyms Used on the HDSL4 Performance History ScreensSES LoswsUsing the Performance Screens to View Alarm Data Alarm History at the DS1 InterfaceRAI Rrai Screen Alarm Front-PanelDescription H4TU-C DS1 Alarms onH4TU-R DS1 Alarms on this PRM-NE PrmnAlarm History at the HDSL4 Interface HDSL4 Alarms at the H4TU-C onlyUsing the Event LOG to Track System Events System Event LogPRM-FE Event Log Entry Messages ListEvent Log Messages Using the Report Menu Report Menu Full ReportReport Types Type Contains the following informationFront-Panel System Alarms TestingSystem Alarms Front-Panel Alarm Description To Inhibit Message aFront-Panel Alarm Description PrmnAlarm Option for DLC Feed Retiring System AlarmsOCT55 Test Pattern with AMI Line Code Remote LOS and AIS ResponseLoopback Operation Loopback SummaryGeneric Loopback Commands Special Loopback CommandsSetting the Loopback Time-Out Option Lbto Manual Loopback SessionLoopback Test Procedures General Troubleshooting TipsLoopback Modes Loopback Code Description Test Set Craft Port Gnlb Test ProceduresSummary of HDSL4 Loopback and Activation Codes MODE/SELName A3LB Test ProcedureA3LB Addressable Repeater Loopback Commands A5LB Test Procedure A5LB Addressable Repeater Loopback CommandsTesting LTPH-UM-1031-03, Issue Bert Signal Pattern Testing with H4TU-C Bert GeneratorBert Signal Generator Option DescriptionTesting with H4TU-R Bert Generator H4TU-R Bert Generator ScreenAppendix a Specifications HDSL4Wideband Jitter Looped UI maximum Narrowband Jitter Looped One-way DS1 Delay 700 µs Wander LoopedSystem H4TU-C Power Parameters Power ConsumptionMaximum Power Dissipation Loop ATTENUATION, Insertion LOSS, and Reach HDSL4 Reach ChartMaximum Current Drain 196 KHz dB/kftFuse Alarm Network Management Control BusSystem Alarm Output Pin Craft PortAppendix B Functional Operation Ground Fault DetectionSpectrum Issues TimingAppendix C Compatibility Systems Integration Appendix D Product SupportSales Assistance Online Technical Support Online Technical PublicationsAppendix E Abbreviations Lbpv LaisLatt LbtoLTPH-UM-1031-03, Issue Certification and Warranty FCC Class a Compliance Limited WarrantyWorld Headquarters For Technical Assistance