Table 15. Front-Panel System Alarms (Continued)
| Alarm | Description | To Inhibit: | |
Message (a) | ||||
|
|
|
RRAI | Remote |
| Alarm Indication at the |
| |
| has errors.) |
Indicates an RAI alarm (yellow) from the CPE Cannot be inhibited. with errors from the line unit or network.
DS1 Bit Error Rate | The DS1 BER has exceeded the set | Select DIS for the DBER system option. | |
|
| threshold limit of approximately |
|
|
| denotes either TUC or TUR. If TUC and TUR |
|
|
| occur at the same time, then TUC displays.) |
|
|
|
|
|
Loss of Frame | The DS1 input does not contain the ESF or SF | Change FRMG option to AUTO or UNFR. | |
|
| frame pattern setting of the FRMG option. |
|
|
| (xxx denotes either TUC or TUR. If TUC and |
|
|
| TUR occur at the same time, then TUC |
|
|
| displays.) |
|
|
|
|
|
PRMN | Performance Report | Set DBER threshold to DIS. | |
| Messaging - Near End | exceeded. |
|
|
|
|
|
PRMF | Performance Report | Set DBER threshold to DIS. | |
| Messaging - Far End | exceeded. |
|
|
|
|
|
HDSL4 Block Error | The HDSL4 BER has exceeded the set | Select NONE for the HBER system option. | |
| Rate | threshold limits of |
|
|
| xxxx denotes TUC, TUR, or first |
|
|
| (DU1U/DU1D) or second (DU2U/DU2D) |
|
|
| doubler HDSL4 upstream or downstream |
|
|
| interface. If TUC and TUR occur at the same |
|
|
| time, then TUC displays. The single x |
|
|
| indicates Loop 1 or Loop 2. |
|
|
|
|
|
Margin Alarm | The margin on the HDSL4 loop has dropped | Set the Margin Alarm Threshold option to | |
|
| below the minimum threshold value set for the | zero. |
|
| system. |
|
|
| xxxx denotes TUC, TUR, or first |
|
|
| (DU1U/DU1D) or second (DU2U/DU2D) |
|
|
| doubler HDSL4 upstream or downstream |
|
|
| interface. If TUC and TUR occur at the same |
|
|
| time, then TUC displays. The single x |
|
|
| indicates Loop 1 or Loop 2. |
|
|
|
|
|
Loop Attenuation | The attenuation on the HDSL4 loop has | Set the HDSL4 Loop Attenuation | |
|
| exceeded the maximum value set for the | Threshold option to zero. |
|
| HDSL4 loop attenuation threshold. |
|
xxxxdenotes TUC, TUR, or first (DU1U/DU1D) or second (DU2U/DU2D) doubler HDSL4 upstream or downstream interface. If TUC and TUR occur at the same time, then TUC displays. The single x indicates Loop 1 or Loop 2.
(a)The message, ALRM, displays prior to any alarm message.
(b)Message displays repeatedly as long as the alarm condition exists and is not included in the priority order.
(c)When the HDSL4 loop loses sync word (LOSW), a system alarm condition exists. However, since the
(d)Only these alarms assert the System Alarm bus on pin H of the
September 12, 2003 | 43 |