ProvisioningLTPH-UM-1031-03, Issue 3
Table 5. H4TU-C-319 List 1 Standard Config Menu Options (Continued)
Standard Config | Screen | Selection | Description | |
Menu Options | Display Code | |||
|
| |||
|
|
|
| |
| TLOS | ENA | Enables a logic loopback at the | |
Loopback |
|
| For priority resolution, see Figure 27 on page 45. | |
|
| DIS | Disables TLOS logic loopback. | |
|
|
|
| |
Network Loopback | NLBP | AIS | Enables the | |
Pattern |
|
| For priority resolution, see Figure 27 on page 45. | |
|
| LOS | Enables the | |
|
|
| loopback. |
Power Back Off - | PBON |
Network |
|
See “Power Back Off |
|
(PBON and PBOC) |
|
Options” on page 22. |
|
DEF | Configures the power output levels of the |
| customer to comply with the Default template as defined in Section 6.1.4.2 of |
| ANSI T1.418. |
ENH | Configures the power output levels of the |
| customer to comply with the Enhanced template as defined in Section 6.1.4.2 |
| of ANSI T1.418. |
Power Back Off - | PBOC |
Customer |
|
See “Power Back Off |
|
(PBON and PBOC) |
|
Options” on page 22. |
|
DEF | Configures the power output levels of the |
| network to comply with the Default template as defined in Section 6.1.4.2 of |
| ANSI T1.418. |
ENH | Configures the power output levels of the |
| network to comply with the Enhanced template as defined in Section 6.1.4.2 |
| of ANSI T1.418. |
Table 6. H4TU-C-319 List 1 ADC Config Menu Options
ADC Config Menu | Screen | Selection | Description |
Options | Display Code | ||
|
|
|
|
Line Power Feed | PWRF | OFF | Disables powering to the HDSL4 pair. |
|
| LOW | Keeps the HDSL4 line voltage at nominal |
|
| HIGH | Keeps the HDSL4 line voltage at nominal ±123 Vdc. |
|
| AUTO | Keeps the |
|
|
| devices (one doubler and one remote unit, or two doubler units). When line |
|
|
| powering of more than two devices is required, the line unit automatically |
|
|
| switches to ±123 Vdc. |
|
|
|
|
Remote Provisioning | RTPV | ENA | Enables remote provisioning. |
|
| DIS | Disables remote provisioning. |
|
|
|
|
Bipolar Violation | BPVT | ENA | Enables BPVs and HDSL4 CRC errors at the DS1 input to be converted into |
Transparency |
|
| DS1 BPVs at the DS1 output at the distant end. This makes HDSL4 |
See “Bipolar |
|
| transparent to BPVs. |
Violation |
| DIS | Disables BPV Transparency. |
Transparency |
|
|
|
(BPVT) Option” on |
|
|
|
page 22. |
|
|
|
DS1 BER Threshold DBER
See “DS1 Bit Error
Rate (DBER) Option” on page 22.
ENA | Enables the fixed |
DIS | Prevents the generation of a system alarm due to DS1 BER. |
Continued
20 | September 12, 2003 |