Chapter 4: Configuring the A164PORT Table

This chapter describes the configurable parameters in the Communication Port Configuration Table (A164PORT).

4.1General Information

The A164PORT table provides information for the operation of the BECO2200 DCA’s communication port(s). One record is required for every communication port configured.

4.2Description of Fields

Where applicable, Table 4 describes the field name, range, special case, and typical value for each field of the A164PORT table. Following the table is a textual description of each field’s meaning.

Table 4 BECO2200 DCA A164PORT Configuration Table

 

Field

 

Range

Special

 

Typical

 

 

 

 

 

 

 

 

 

Communication Port

COM1..COM9

COM0 is typically reserved for

 

COM1

 

 

Name

COMA..COMZ

WESMAINT

 

 

 

 

 

 

 

 

 

 

 

 

Communication Port

0

= None

N/A

 

1 = Even Parity

 

 

Parity

1

= Even

 

 

 

 

 

 

2

= Odd

 

 

 

 

 

 

 

 

 

 

 

 

Baud rate

110, 300, 600, 1200,

N/A

 

4800 or 9600

 

 

 

2400, 4800, 9600

 

 

 

 

 

 

 

 

 

 

 

 

RTS On Time

0..65535

Must be at least 1 if modem

 

N/A

 

 

 

 

 

signals are used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Restricted

 

 

A164-0CG-1.00-2

 

 

 

Full

 

 

 

9

 

 

 

 

 

Image 25
Contents BECCO2200 DCA Configuration GuideTrademark Notices Table of Contents Configuring the A164MODE Table Configuring the A164DTBL Configuration Table BECCO2200 DCA List of Figures Viii List of Tables BECCO2200 DCA Purpose of this Guide About this GuideWho Should Use this Guide Introduction to the Wesdac D20 RTU GEN-0003 Additional DocumentationHow this Guide is Organized Xiv Overview Xvi BECO2200 DCA Configuration Tables Configuration TablesConfiguration Sequence Wesdac Point Allocation Configuring Win for the BECO2200 DCABinary Outputs Binary InputsCounters Analog InputsGeneral Information Configuring the A164APPL TableDescription of Fields SOE Buffer Size Adjustment Reply Buffer Size AdjustmentDCA Index SOE Buffer Overflow OptionDevice Event Response Time BECCO2200 DCA BECO2200 DCA A164PORT Configuration Table Configuring the A164PORT TableCommunication Port Parity Communication Port NameBaud Rate RTS On TimeRemote Reply Timeout Intercharacter TimeoutRTS Off Time Retries Before Failure Line Idle TimeFailures Before Off-line Number of Devices on PortBECO2200 DCA A164UNIT Configuration Table Configuring the A164UNIT TableUnit Type Remote AddressType 0 Read Interval Type 2 Read Interval Type 1 Read IntervalType 3 Read Interval Type 4 Read IntervalType 8 Read Interval Type 7 Read IntervalTime Synchronization Interval Configuring the A164MODE Table A164MODE First DvcfNumber of Dvcf BECCO2200 DCA Configuring the A164DVCF Configuration Table Number of Units First UnitFirst Data Record Number of Data RecordsConfiguring the A164DTBL Configuration Table Point Number Table TypeData Value Appendix AMessages Logged by the BECO2200 DCA Fatal Error MessagesF101 Bad A164PORT record counts, must be F100 Bad A164APPL record counts, must beF102 Bad A164UNIT record counts, must be F103 Bad Cfgdca record counts, must beF105 Invalid SOE Overflow parameter F107 x WESDACy pnts configured, z requiredF106 Total # devices exceeds Unit size F110 Fatal errors exist in configuration F108 x table creation errorF109 Cannot find x database table F111 Bad A164DVCF record counts, must beF121 Mode Record x, invalid Number of Dvcf F120 Mode Record x, invalid First DvcfF122 Dvcf Record x, invalid First Unit F123 Dvcf Record x, invalid Number of UnitsF201 Error x signaling A164-D-00 process F200 Error x on win openF203 Error x creating A164-y-z exchange F125 Dvcf Record x, invalid Number of Type-PointF205 Error x activating A164-y-z process F204 Error x spawning A164-y-z processF206 Process A164-x-y died while initializing F207 Unable to allocate buffersE300 Port rec x, invalid baud rate Non-Fatal Error MessagesE301 Port rec x, invalid failures before offline E302 Port rec x, num of devices exceeds UnitE307 Unit rec x, configuration bad E303 Port rec x, configuration badE304 Port rec x, invalid unit address E305 Unit rec x, invalid unit typeE400 Error x opening port y E399 Non-fatal errors exist in configurationE401 Error x setting character port E308 Port rec x, num of devices cannot =E403 Error x creating A164-y-z exchange E402 Error x setting SIO timersE404 Error x spawning A164-y-z process E405 Error x activating A164-y-z processE409 Error x, invalid start signal from Spawner E407 Error x signalling A164-y-z processE406 Process A164-x-y died while initializing E408 Unable to allocate polling listPSOS Interface Warnings I700 Port rec x, invalid reply time-out Information MessagesI701 Port rec x, invalid RTS on time I702 Port rec x, invalid RTS off timeI704 No Configuration deleting I703 Port rec x, invalid intercharacter timeoutI705 Port rec x, no polling required Demand Scan Failed Output Request Return CodesDo Operate Failed AO Operate FailedAscii Glossary of TermsRAM Menu-oriented software program that operates on a personal A164-0CG-1.00-2Restricted List of Acronyms and Abbreviations