Page 58

 

BECCO2200 DCA

GE Energy Services

Configuration Guide

Data-collection

A software application that acquires data from and sends data to

application

various intelligent electronic devices. Abbreviated as DCA.

 

Data-translation

A software application that translates data from one form to

 

application

another (for example digital input to analog input). A data-

 

 

translation application usually has no direct interface to external

 

devices. Abbreviated as DTA.

 

Decimal

A number system having ten symbols, and where values are

 

 

expressed in the base ten number system.

 

Hexadecimal

A number system having 16 symbols, and where values are

 

 

expressed in the base 16 number system. Commonly used to

 

 

abbreviate binary data. Sometimes referred to as hex.

 

 

Hexadecimal numbers are often preceded by the prefix 0x.

 

Master

The client or host station or computer, with which the RTU

 

 

equipment communicates. Also referred to as a host or host

 

 

computer.

 

Non-volatile

A semi-permanent type of data storage (memory)

 

random-access

 

 

memory

that is backed up by batteries to maintain stored data even if

 

 

system power is lost. Can be both read and changed by the

 

 

system. Abbreviated as NVRAM.

 

Port

An interface point connecting a communications channel and a

 

device.

 

Random-access

A type of temporary data storage (memory) that can be read and

memory

changed while the computer is in use. Data stored in random-

 

access memory is lost if the system loses power. Abbreviated as

 

RAM.

 

Read-only

A type of permanent data storage (memory) that can be read but

memory

not altered by the system. Data stored in read-only memory is not

 

affected by power loss to the system. Abbreviated as ROM.

 

Remote terminal

A piece of equipment located at a distance from a master station

unit

to monitor and control the status of outlying equipment, and to

 

communicate the information back to the master station or host.

 

Abbreviated as RTU.

 

Sequence of

A time-tagged change of state, logged as part of a chronological

events

record of significant changes in the condition of a particular point

 

or points being monitored. Abbreviated as SOE.

 

Slave

See sub-remote unit.

 

Source code

A piece of code that has not yet been compiled or assembled (that

 

is, it is still in the language it was programmed in) and so cannot

 

yet run on a machine.

 

Sub-remote unit

A physical device (e.g., peripheral boards, D20 RTUs, non-D20

 

RTUs, meters, or other intelligent electronic device) that collects

 

data, processes it in some way, and communicates it to a master

 

remote unit (MRU). SRUs (also called slave units) are able to

 

respond to commands from MRUs.

 

WESDAC

A module of software that manages the transfer, storage, and

 

 

 

 

A164-0CG-1.00-2

Restricted

42

 

Full

 

 

Image 58
Contents Configuration Guide BECCO2200 DCATrademark Notices Table of Contents Configuring the A164MODE Table Configuring the A164DTBL Configuration Table BECCO2200 DCA List of Figures Viii List of Tables BECCO2200 DCA Purpose of this Guide About this GuideWho Should Use this Guide Additional Documentation Introduction to the Wesdac D20 RTU GEN-0003How this Guide is Organized Xiv Overview Xvi Configuration Tables BECO2200 DCA Configuration TablesConfiguration Sequence Configuring Win for the BECO2200 DCA Wesdac Point AllocationCounters Binary InputsBinary Outputs Analog InputsGeneral Information Configuring the A164APPL TableDescription of Fields DCA Index Reply Buffer Size AdjustmentSOE Buffer Size Adjustment SOE Buffer Overflow OptionDevice Event Response Time BECCO2200 DCA Configuring the A164PORT Table BECO2200 DCA A164PORT Configuration TableBaud Rate Communication Port NameCommunication Port Parity RTS On TimeRemote Reply Timeout Intercharacter TimeoutRTS Off Time Failures Before Off-line Line Idle TimeRetries Before Failure Number of Devices on PortConfiguring the A164UNIT Table BECO2200 DCA A164UNIT Configuration TableUnit Type Remote AddressType 0 Read Interval Type 3 Read Interval Type 1 Read IntervalType 2 Read Interval Type 4 Read IntervalType 8 Read Interval Type 7 Read IntervalTime Synchronization Interval Configuring the A164MODE Table First Dvcf A164MODENumber of Dvcf BECCO2200 DCA Configuring the A164DVCF Configuration Table First Data Record First UnitNumber of Units Number of Data RecordsConfiguring the A164DTBL Configuration Table Point Number Table TypeData Value Fatal Error Messages Appendix AMessages Logged by the BECO2200 DCAF102 Bad A164UNIT record counts, must be F100 Bad A164APPL record counts, must beF101 Bad A164PORT record counts, must be F103 Bad Cfgdca record counts, must beF105 Invalid SOE Overflow parameter F107 x WESDACy pnts configured, z requiredF106 Total # devices exceeds Unit size F109 Cannot find x database table F108 x table creation errorF110 Fatal errors exist in configuration F111 Bad A164DVCF record counts, must beF122 Dvcf Record x, invalid First Unit F120 Mode Record x, invalid First DvcfF121 Mode Record x, invalid Number of Dvcf F123 Dvcf Record x, invalid Number of UnitsF203 Error x creating A164-y-z exchange F200 Error x on win openF201 Error x signaling A164-D-00 process F125 Dvcf Record x, invalid Number of Type-PointF206 Process A164-x-y died while initializing F204 Error x spawning A164-y-z processF205 Error x activating A164-y-z process F207 Unable to allocate buffersE301 Port rec x, invalid failures before offline Non-Fatal Error MessagesE300 Port rec x, invalid baud rate E302 Port rec x, num of devices exceeds UnitE304 Port rec x, invalid unit address E303 Port rec x, configuration badE307 Unit rec x, configuration bad E305 Unit rec x, invalid unit typeE401 Error x setting character port E399 Non-fatal errors exist in configurationE400 Error x opening port y E308 Port rec x, num of devices cannot =E404 Error x spawning A164-y-z process E402 Error x setting SIO timersE403 Error x creating A164-y-z exchange E405 Error x activating A164-y-z processE406 Process A164-x-y died while initializing E407 Error x signalling A164-y-z processE409 Error x, invalid start signal from Spawner E408 Unable to allocate polling listPSOS Interface Warnings I701 Port rec x, invalid RTS on time Information MessagesI700 Port rec x, invalid reply time-out I702 Port rec x, invalid RTS off timeI704 No Configuration deleting I703 Port rec x, invalid intercharacter timeoutI705 Port rec x, no polling required Do Operate Failed Output Request Return CodesDemand Scan Failed AO Operate FailedGlossary of Terms AsciiRAM Menu-oriented software program that operates on a personal A164-0CG-1.00-2Restricted List of Acronyms and Abbreviations