GE BECCO2200 E406 Process A164-x-y died while initializing, E408 Unable to allocate polling list

Page 52

 

BECCO2200 DCA

GE Energy Services

Configuration Guide

E406: Process A164-<x>-<y> died while initializing

Cause:

Process A164-<x>-<y> was deleted during its initialization.

Effect:

If <y> equals C: Communication to all devices configured for this port will be unavailable.

If <y> equals P: No polling of devices will occur for this port. Demand scanning is available.

Remedy:

Address any fatal or non-fatal error message preceding this message.

Call the Customer Service Department and report this error.

E407: Error <x> signalling A164-<y>-<z> process

Cause:

The BECO2200 DCA was unable to signal the A164-<y>-<z> process. The error code returned was <x>.

Effect:

If <y> equals C: Communication to all devices configured for this port will be unavailable.

If <y> equals P: No polling of devices will occur for this port. Demand scanning is available.

Remedy:

Call the Customer Service Department and report this error.

E408: Unable to allocate polling list

Cause:

The BECO2200 DCA was unable to allocate enough memory for is polling lists.

Effect:

The BECO2200 DCA will be unable to poll any of the devices configured. Demand scanning is available.

Remedy:

Reduce the amount of RAM used by this and any other application in the system. The parameters that affect the amount of RAM required by this application are noted in their associated chapters.

Upgrade the GE Energy Services product to a model with more memory.

Call the Customer Service department and report this error.

E409: Error <x>, invalid start signal from Spawner

Cause:

This process failed to receive the start signal from the BECO2200 DCA spawner. The error code returned was <x>.

A164-0CG-1.00-2Restricted

36

Full

 

Image 52
Contents Configuration Guide BECCO2200 DCATrademark Notices Table of Contents Configuring the A164MODE Table Configuring the A164DTBL Configuration Table BECCO2200 DCA List of Figures Viii List of Tables BECCO2200 DCA Purpose of this Guide About this GuideWho Should Use this Guide Additional Documentation Introduction to the Wesdac D20 RTU GEN-0003How this Guide is Organized Xiv Overview Xvi Configuration Tables BECO2200 DCA Configuration TablesConfiguration Sequence Configuring Win for the BECO2200 DCA Wesdac Point AllocationBinary Inputs Binary OutputsCounters Analog InputsGeneral Information Configuring the A164APPL TableDescription of Fields Reply Buffer Size Adjustment SOE Buffer Size AdjustmentDCA Index SOE Buffer Overflow OptionDevice Event Response Time BECCO2200 DCA Configuring the A164PORT Table BECO2200 DCA A164PORT Configuration TableCommunication Port Name Communication Port ParityBaud Rate RTS On TimeRemote Reply Timeout Intercharacter TimeoutRTS Off Time Line Idle Time Retries Before FailureFailures Before Off-line Number of Devices on PortConfiguring the A164UNIT Table BECO2200 DCA A164UNIT Configuration TableUnit Type Remote AddressType 0 Read Interval Type 1 Read Interval Type 2 Read IntervalType 3 Read Interval Type 4 Read IntervalType 8 Read Interval Type 7 Read IntervalTime Synchronization Interval Configuring the A164MODE Table First Dvcf A164MODENumber of Dvcf BECCO2200 DCA Configuring the A164DVCF Configuration Table First Unit Number of UnitsFirst Data Record Number of Data RecordsConfiguring the A164DTBL Configuration Table Point Number Table TypeData Value Fatal Error Messages Appendix AMessages Logged by the BECO2200 DCAF100 Bad A164APPL record counts, must be F101 Bad A164PORT record counts, must beF102 Bad A164UNIT record counts, must be F103 Bad Cfgdca record counts, must beF105 Invalid SOE Overflow parameter F107 x WESDACy pnts configured, z requiredF106 Total # devices exceeds Unit size F108 x table creation error F110 Fatal errors exist in configurationF109 Cannot find x database table F111 Bad A164DVCF record counts, must beF120 Mode Record x, invalid First Dvcf F121 Mode Record x, invalid Number of DvcfF122 Dvcf Record x, invalid First Unit F123 Dvcf Record x, invalid Number of UnitsF200 Error x on win open F201 Error x signaling A164-D-00 processF203 Error x creating A164-y-z exchange F125 Dvcf Record x, invalid Number of Type-PointF204 Error x spawning A164-y-z process F205 Error x activating A164-y-z processF206 Process A164-x-y died while initializing F207 Unable to allocate buffersNon-Fatal Error Messages E300 Port rec x, invalid baud rateE301 Port rec x, invalid failures before offline E302 Port rec x, num of devices exceeds UnitE303 Port rec x, configuration bad E307 Unit rec x, configuration badE304 Port rec x, invalid unit address E305 Unit rec x, invalid unit typeE399 Non-fatal errors exist in configuration E400 Error x opening port yE401 Error x setting character port E308 Port rec x, num of devices cannot =E402 Error x setting SIO timers E403 Error x creating A164-y-z exchangeE404 Error x spawning A164-y-z process E405 Error x activating A164-y-z processE407 Error x signalling A164-y-z process E409 Error x, invalid start signal from SpawnerE406 Process A164-x-y died while initializing E408 Unable to allocate polling listPSOS Interface Warnings Information Messages I700 Port rec x, invalid reply time-outI701 Port rec x, invalid RTS on time I702 Port rec x, invalid RTS off timeI704 No Configuration deleting I703 Port rec x, invalid intercharacter timeoutI705 Port rec x, no polling required Output Request Return Codes Demand Scan FailedDo Operate Failed AO Operate FailedGlossary of Terms AsciiRAM Menu-oriented software program that operates on a personal A164-0CG-1.00-2Restricted List of Acronyms and Abbreviations