GE BECCO2200 manual Appendix AMessages Logged by the BECO2200 DCA, Fatal Error Messages

Page 41

Appendix A:Messages Logged by the BECO2200 DCA

This appendix describes all fatal, error, warning, and information messages logged by the BECO2200 DCA to the WESMAINT Error Log. This appendix also provides an explanation of all output request return codes.

Messages logged to the WESMAINT Error Log by the BECO2200 DCA will be pre- pended with a process name. This name will be one of the following:

A164:

or

A164-<x>-<y>:

where: <x> represents the process type (C,P,M,D) <y> represents the process invocation number

A.1 Fatal Error Messages

During startup, the BECO2200 DCA checks its configuration and begins its initialization. If the BECO2200 DCA encounters errors in the configuration or the initialization that will impede the overall functionality of the DCA, it will log an error message to the WESMAINT Error Log and suspend.

This section contains a description of all fatal errors. Expressions in angular brackets like “<x>”, are filled with the appropriate values by the BECO2200 DCA. Each fatal error message contains a unique identification number, within the range of F100 through F299.

Restricted

A164-0CG-1.00-2

Full

25

 

Image 41
Contents BECCO2200 DCA Configuration GuideTrademark Notices Table of Contents Configuring the A164MODE Table Configuring the A164DTBL Configuration Table BECCO2200 DCA List of Figures Viii List of Tables BECCO2200 DCA Who Should Use this Guide About this GuidePurpose of this Guide Introduction to the Wesdac D20 RTU GEN-0003 Additional DocumentationHow this Guide is Organized Xiv Overview Xvi BECO2200 DCA Configuration Tables Configuration TablesConfiguration Sequence Wesdac Point Allocation Configuring Win for the BECO2200 DCABinary Outputs Binary InputsCounters Analog InputsDescription of Fields Configuring the A164APPL TableGeneral Information SOE Buffer Size Adjustment Reply Buffer Size AdjustmentDCA Index SOE Buffer Overflow OptionDevice Event Response Time BECCO2200 DCA BECO2200 DCA A164PORT Configuration Table Configuring the A164PORT TableCommunication Port Parity Communication Port NameBaud Rate RTS On TimeRTS Off Time Intercharacter TimeoutRemote Reply Timeout Retries Before Failure Line Idle TimeFailures Before Off-line Number of Devices on PortBECO2200 DCA A164UNIT Configuration Table Configuring the A164UNIT TableType 0 Read Interval Remote AddressUnit Type Type 2 Read Interval Type 1 Read IntervalType 3 Read Interval Type 4 Read IntervalTime Synchronization Interval Type 7 Read IntervalType 8 Read Interval Configuring the A164MODE Table A164MODE First DvcfNumber of Dvcf BECCO2200 DCA Configuring the A164DVCF Configuration Table Number of Units First UnitFirst Data Record Number of Data RecordsConfiguring the A164DTBL Configuration Table Data Value Table TypePoint Number Appendix AMessages Logged by the BECO2200 DCA Fatal Error MessagesF101 Bad A164PORT record counts, must be F100 Bad A164APPL record counts, must beF102 Bad A164UNIT record counts, must be F103 Bad Cfgdca record counts, must beF106 Total # devices exceeds Unit size F107 x WESDACy pnts configured, z requiredF105 Invalid SOE Overflow parameter F110 Fatal errors exist in configuration F108 x table creation errorF109 Cannot find x database table F111 Bad A164DVCF record counts, must beF121 Mode Record x, invalid Number of Dvcf F120 Mode Record x, invalid First DvcfF122 Dvcf Record x, invalid First Unit F123 Dvcf Record x, invalid Number of UnitsF201 Error x signaling A164-D-00 process F200 Error x on win openF203 Error x creating A164-y-z exchange F125 Dvcf Record x, invalid Number of Type-PointF205 Error x activating A164-y-z process F204 Error x spawning A164-y-z processF206 Process A164-x-y died while initializing F207 Unable to allocate buffersE300 Port rec x, invalid baud rate Non-Fatal Error MessagesE301 Port rec x, invalid failures before offline E302 Port rec x, num of devices exceeds UnitE307 Unit rec x, configuration bad E303 Port rec x, configuration badE304 Port rec x, invalid unit address E305 Unit rec x, invalid unit typeE400 Error x opening port y E399 Non-fatal errors exist in configurationE401 Error x setting character port E308 Port rec x, num of devices cannot =E403 Error x creating A164-y-z exchange E402 Error x setting SIO timersE404 Error x spawning A164-y-z process E405 Error x activating A164-y-z processE409 Error x, invalid start signal from Spawner E407 Error x signalling A164-y-z processE406 Process A164-x-y died while initializing E408 Unable to allocate polling listPSOS Interface Warnings I700 Port rec x, invalid reply time-out Information MessagesI701 Port rec x, invalid RTS on time I702 Port rec x, invalid RTS off timeI705 Port rec x, no polling required I703 Port rec x, invalid intercharacter timeoutI704 No Configuration deleting Demand Scan Failed Output Request Return CodesDo Operate Failed AO Operate FailedAscii Glossary of TermsRAM Menu-oriented software program that operates on a personal A164-0CG-1.00-2Restricted List of Acronyms and Abbreviations