Effect:

This process will not start. The associated functionality of this process will not be available:

A164-D-00: The Event process reports all events to WIN.

A164-M-00: The Command process receives and interprets WIN command requests.

A164-C-00: The Communication process transmits and receives all messages for a single communication port.

A164-P-00: The Poller process initiates all polling for al single communication port.

Remedy:

Call the Customer Service department and report this error.

A.3 Warning Messages

This section describes the warning messages the BECO2200 DCA may log to the WESMAINT Error Log. The warnings are divided into two groups: pSOS Interface Warnings and WIN Interface Warnings. If you find any of these messages in the WESMAINT Error Log, contact the Customer Service Department and report the message.

Expressions in angular brackets like “<x>”, are filled with the appropriate values by the BECO2200 DCA.

pSOS Interface Warnings

The BECO2200 DCA uses a number of message exchanges and signals for inter-process communications. If a process is unable to send or receive a message or a signal, the functionality of the BECO2200 DCA may be compromised. pSOS exchange warnings are numbered from W500 through W599.

W500: Error <x> on send_x to A164-D-00

W501: Error <x> on send_x to A164-C-<y>

W502: Error <x> on jam_x to A164-C-<y>

W503: Error <x> on wait_v from A164-C-<y>

W504: Error <x> signaling back response

W505: Error <x> on req_x

WIN Interface Warnings

During run-time, the BECO2200 DCA interfaces to the WESDAC Interface Node (WIN) by writing various commands. If any of these writes fail, the command can not be passed to other applications in the system. WIN interface warnings are numbered from W600 through W699.

W600: Error <x> on win read

W601: Error <x> on ACK/NACK win write

W602: Error <x> on DATA UPDATED CMD win write

W603: Error <x> on TIME SYNC win write

W604: Error <x> on WES<y> REST_COMM win write

W605: Error <x> on WES<y> LOSS_COMM win write

W606: Error <x> on WES<y> ON_LINE win write

W607: Error <x> on WES<y> OFF_LINE win write

Restricted

A164-0CG-1.00-2

Full

37

 

Image 53
Contents BECCO2200 DCA Configuration GuideTrademark Notices Table of Contents Configuring the A164MODE Table Configuring the A164DTBL Configuration Table BECCO2200 DCA List of Figures Viii List of Tables BECCO2200 DCA Who Should Use this Guide About this GuidePurpose of this Guide Introduction to the Wesdac D20 RTU GEN-0003 Additional DocumentationHow this Guide is Organized Xiv Overview Xvi BECO2200 DCA Configuration Tables Configuration TablesConfiguration Sequence Wesdac Point Allocation Configuring Win for the BECO2200 DCABinary Outputs Binary InputsCounters Analog InputsDescription of Fields Configuring the A164APPL TableGeneral Information SOE Buffer Size Adjustment Reply Buffer Size AdjustmentDCA Index SOE Buffer Overflow OptionDevice Event Response Time BECCO2200 DCA BECO2200 DCA A164PORT Configuration Table Configuring the A164PORT TableCommunication Port Parity Communication Port NameBaud Rate RTS On TimeRTS Off Time Intercharacter TimeoutRemote Reply Timeout Retries Before Failure Line Idle TimeFailures Before Off-line Number of Devices on PortBECO2200 DCA A164UNIT Configuration Table Configuring the A164UNIT TableType 0 Read Interval Remote AddressUnit Type Type 2 Read Interval Type 1 Read IntervalType 3 Read Interval Type 4 Read IntervalTime Synchronization Interval Type 7 Read IntervalType 8 Read Interval Configuring the A164MODE Table A164MODE First DvcfNumber of Dvcf BECCO2200 DCA Configuring the A164DVCF Configuration Table Number of Units First UnitFirst Data Record Number of Data RecordsConfiguring the A164DTBL Configuration Table Data Value Table TypePoint Number Appendix AMessages Logged by the BECO2200 DCA Fatal Error MessagesF101 Bad A164PORT record counts, must be F100 Bad A164APPL record counts, must beF102 Bad A164UNIT record counts, must be F103 Bad Cfgdca record counts, must beF106 Total # devices exceeds Unit size F107 x WESDACy pnts configured, z requiredF105 Invalid SOE Overflow parameter F110 Fatal errors exist in configuration F108 x table creation errorF109 Cannot find x database table F111 Bad A164DVCF record counts, must beF121 Mode Record x, invalid Number of Dvcf F120 Mode Record x, invalid First DvcfF122 Dvcf Record x, invalid First Unit F123 Dvcf Record x, invalid Number of UnitsF201 Error x signaling A164-D-00 process F200 Error x on win openF203 Error x creating A164-y-z exchange F125 Dvcf Record x, invalid Number of Type-PointF205 Error x activating A164-y-z process F204 Error x spawning A164-y-z processF206 Process A164-x-y died while initializing F207 Unable to allocate buffersE300 Port rec x, invalid baud rate Non-Fatal Error MessagesE301 Port rec x, invalid failures before offline E302 Port rec x, num of devices exceeds UnitE307 Unit rec x, configuration bad E303 Port rec x, configuration badE304 Port rec x, invalid unit address E305 Unit rec x, invalid unit typeE400 Error x opening port y E399 Non-fatal errors exist in configurationE401 Error x setting character port E308 Port rec x, num of devices cannot =E403 Error x creating A164-y-z exchange E402 Error x setting SIO timersE404 Error x spawning A164-y-z process E405 Error x activating A164-y-z processE409 Error x, invalid start signal from Spawner E407 Error x signalling A164-y-z processE406 Process A164-x-y died while initializing E408 Unable to allocate polling listPSOS Interface Warnings I700 Port rec x, invalid reply time-out Information MessagesI701 Port rec x, invalid RTS on time I702 Port rec x, invalid RTS off timeI705 Port rec x, no polling required I703 Port rec x, invalid intercharacter timeoutI704 No Configuration deleting Demand Scan Failed Output Request Return CodesDo Operate Failed AO Operate FailedAscii Glossary of TermsRAM Menu-oriented software program that operates on a personal A164-0CG-1.00-2Restricted List of Acronyms and Abbreviations