Extron electronic IPL T PCS4 manual Assigning passwords, To assign passwords, Removing passwords

Page 31

Assigning passwords

The Passwords screen allows you to assign passwords to the administrator and user access levels. The administrator password gives access to all IPL T PCS4 web pages, enabling the administrator to configure the PCS4.

The user password provides access only to the System Status web page. If you are logged in as user, you see only the Status tab with the System Status screen. You cannot make any configuration changes.

To assign passwords:

1.On the Configuration page, select Passwords from the side-bar menu.

2.Enter the new administrator password in the Administrator Password field.

NOTE: Passwords must contain 4 to 12 alphanumeric characters. Symbols and spaces are not allowed, and the passwords are case sensitive.

3.In the Re-enter Admin Password field, enter the same password again to confirm it.

4.If you want to assign a user password, enter it in the User Password field.

NOTE: You cannot assign a User password unless an administrator password has

either been assigned or is being assigned at the same time.

5.Reenter the same user password in the Re-enter User Password field.

Figure 15. Passwords Screen with Administrator and User Passwords Entered

6.Click Submit to set the passwords.

Removing passwords

To remove a password:

1.On the Configuration page, select Passwords from the sidebar menu.

2.In the Administrator Password, the User Password, or both fields, delete the characters that are there, and press the <Spacebar> on your computer keyboard to enter a space.

3.Repeat step 2 in the Re-enter Admin Password, the Re-enter User Password, or both fields.

4.Click Submit.

NOTE: Deleting the administrator password also deletes the user password.

IPL T PCS4 • HTML Configuration and Control 25

Image 31
Contents IPL T PCS4i IPL T PCS4Safety Instructions English FCC Class a Notice Conventions Used in this Guide Software CommandsNotifications Contents IPL T PCS4 Contents About the IPL T PCS4 FeaturesIntroduction About this GuideIPL T PCS4 Application DiagramsConnection Diagram for IPL T PCS4i Installation Overview Installation Rear PanelsIPL T PCS4i Rear Panel 220 VAC Rear PanelsLAN Port Cabling Setting Up the LAN PortConnecting the Devices Configuring the LAN PortIPL T PCS4 Installation and Rear Panel Front Panel Features Front Panel Features OperationSetting Up Power Control Setting Up the System Using the Front PanelSetting Power Level Reference Thresholds Setting the Full power threshold None and Not Set thresholds If the receptacle Is set to Power level Receptacle FullStandby Clearing thresholds Front panel Security Lockout Executive ModeLED lit Group Red power LED lit Group Grouping ReceptaclesResult Resetting the UnitMode ActivationHold the Reset button in until the Power LED blinks once Configuring the Hardware Configuration ControlSetting Up the Computer Using ARP ARP-S Command Screen Screen Showing the Ping Command Setting Up the Computer Using a Web BrowserSetting up the computer for IP communication Subnet mask Default gateway Blank or Example of a Default System Settings Configuring the IPL T PCS4 using a web browserPassword Prompt Window Using the Embedded Web PagesSystem Status Web Viewing the System StatusSpecifying system settings ConfigurationIP settings Date and time settings To assign passwords Assigning passwordsRemoving passwords Mail Alerts Screen Upper Portion Entering e-mail addresses for alertsManaging receptacles Upgrading firmwareGrouping receptacles Switching power to receptacles on and offMonitoring Settings section Monitoring the receptacles and setting the alarmAlarm Relay Settings section Scheduling an individual receptacle Scheduling power to receptaclesAll receptacles on and off Scheduling receptacles by day of the weekFile Management One receptacle, power on or offAdding a directory Uploading files to the webOther file management functions Server Side Includes SSIs Custom Web PagesQuery Strings Code example Example of a Query String CommandBrowser View of Previous Html Source Code URL EncodingUnsafe characters Reserved charactersCharacters Hex Dec Accessing and Using Telnet Port Device Power ControlCustom Web Pages Power Connections TroubleshootingNetwork Connections Successful Ping Command ResponseDownloading Global Configurator Software Host-to-Interface Communication SIS Programming ControlMessages Initiated by the IPL T PCS4 Error Responses Password InformationError Response References Telnet Web Browser Using the Command and Response TableExample Symbol DefinitionsX5@ X71 Power Receptacle Monitoring and Alarm Functions Command and Response Table for SIS CommandsWeb Browser-specific Commands Set GMT offset24 View GMT offset Password and Security SettingsDirectory Commands Below Telnet text responses AC control interface SpecificationsReference Material Ethernet control interfaceGeneral Alarm relay controlMounting the IPL T PCS4 Interface Part Numbers and AccessoriesMounting the IPL T PCS4 on a Rack Shelf Rack mounting procedureMounting the IPL T PCS4 under Furniture Under-desk Mounting10/100Base-T GlossaryDriver Power level reference threshold Subnet Europe USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East