Extron electronic IPL T PCS4i Reference Material, Specifications, Ethernet control interface

Page 60

Reference

Material

This section contains reference information on the IPL T PCS4 and IPL T PCS4i. The following topics are covered:

Specifications

Part Numbers and Accessories

Mounting the IPL T PCS4 Interface

Specifications

Ethernet control interface

Connectors

1 female RJ-45 female connector

Data rate

10/100Base-T, half/full duplex with autodetect

Protocols

ARP, ICMP (ping), IP, TCP, UDP, DHCP, HTTP, SMTP, Telnet

Default settings

Link speed and duplex level = autodetected

 

IP address = 192.168.254.254

 

Subnet mask = 255.255.0.0

 

Gateway = 0.0.0.0

 

DHCP = off

Web server

Up to 200 simultaneous sessions

 

960 kB nonvolatile user memory

Program control

Extron Simple Instruction Set (SIS)

Global Viewer requirements

Microsoft Internet Explorer ver. 6 or higher

AC control interface

Connectors

 

IPL T PCS4

4 USA/Edison power connectors

IPL T PCS4i

4 IEC power connectors

Voltage

 

IPL T PCS4

120 VAC, 50-60 Hz

IPL T PCS4i

220 VAC, 50-60 Hz

Minimum AC load

 

IPL T PCS4

20 mA, 2.4 watts at 120 VAC

IPL T PCS4i

20 mA, 4.4 watts at 220 VAC

Maximum AC load, aggregate

 

IPL T PCS4

10 A, 1200 watts at 120 VAC

IPL T PCS4i

10 A, 2200 watts at 220 VAC

Maximum AC load, individual

 

IPL T PCS4

10 A, 1200 watts at 120 VAC

IPL T PCS4i

10 A, 2200 watts at 220 VAC

IPL T PCS4 • Reference Material 54

Image 60
Contents IPL T PCS4 IPL T PCS4iSafety Instructions English FCC Class a Notice Software Commands Conventions Used in this GuideNotifications Contents IPL T PCS4 Contents Features IntroductionAbout this Guide About the IPL T PCS4Application Diagrams IPL T PCS4Connection Diagram for IPL T PCS4i Installation Rear Panels Installation OverviewRear Panels IPL T PCS4i Rear Panel 220 VACSetting Up the LAN Port Connecting the DevicesConfiguring the LAN Port LAN Port CablingIPL T PCS4 Installation and Rear Panel Front Panel Features Operation Front Panel FeaturesSetting Up the System Using the Front Panel Setting Up Power ControlSetting Power Level Reference Thresholds Setting the Full power threshold If the receptacle Is set to Power level Receptacle Full None and Not Set thresholdsStandby Front panel Security Lockout Executive Mode LED lit Group Red power LED lit GroupGrouping Receptacles Clearing thresholdsResetting the Unit ModeActivation ResultHold the Reset button in until the Power LED blinks once Configuration Control Configuring the HardwareSetting Up the Computer Using ARP ARP-S Command Screen Setting Up the Computer Using a Web Browser Screen Showing the Ping CommandSetting up the computer for IP communication Subnet mask Default gateway Blank or Configuring the IPL T PCS4 using a web browser Example of a Default System SettingsUsing the Embedded Web Pages Password Prompt WindowViewing the System Status System Status WebConfiguration Specifying system settingsIP settings Date and time settings Assigning passwords To assign passwordsRemoving passwords Entering e-mail addresses for alerts Mail Alerts Screen Upper PortionUpgrading firmware Managing receptaclesSwitching power to receptacles on and off Grouping receptaclesMonitoring the receptacles and setting the alarm Monitoring Settings sectionAlarm Relay Settings section Scheduling power to receptacles Scheduling an individual receptacleScheduling receptacles by day of the week All receptacles on and offOne receptacle, power on or off File ManagementUploading files to the web Adding a directoryOther file management functions Custom Web Pages Server Side Includes SSIsQuery Strings Example of a Query String Command Code exampleURL Encoding Browser View of Previous Html Source CodeReserved characters Unsafe charactersCharacters Hex Dec Device Power Control Accessing and Using Telnet PortCustom Web Pages Troubleshooting Power ConnectionsSuccessful Ping Command Response Network ConnectionsDownloading Global Configurator Software SIS Programming Control Host-to-Interface CommunicationMessages Initiated by the IPL T PCS4 Password Information Error ResponsesError Response References Using the Command and Response Table Telnet Web BrowserSymbol Definitions ExampleX5@ X71 Command and Response Table for SIS Commands Power Receptacle Monitoring and Alarm FunctionsWeb Browser-specific Commands Password and Security Settings Set GMT offset24 View GMT offsetDirectory Commands Below Telnet text responses Specifications Reference MaterialEthernet control interface AC control interfaceAlarm relay control GeneralPart Numbers and Accessories Mounting the IPL T PCS4 InterfaceRack mounting procedure Mounting the IPL T PCS4 on a Rack ShelfUnder-desk Mounting Mounting the IPL T PCS4 under FurnitureGlossary 10/100Base-TDriver Power level reference threshold Subnet USA, Canada, South America Japan Central America Europe, Africa, and the Middle China EastAsia Middle East Europe
Related manuals
Manual 2 pages 35.37 Kb