This section contains a description of the IPL T PCS4 and IPL T PCS4i front panel features and instructions for setting up the PCS4 using the front panel. The following topics are discussed:

Front Panel Features

Setting Up the System Using the Front Panel

Resetting the Unit

Front Panel Features

7

6

7

6

7

6

7

6

 

IPL T PCS4

 

 

4

 

1

2

3

1

F

F

F

F

R

 

 

 

 

S

S

S

S

 

2

 

3

 

SET REFERENCE

STANDBY FULL

100

 

LINK

5

ACT

 

4

Figure 7. IPL T PCS4 and IPL T PCS4i Front Panel

APower LED (green) — When this LED is lit, the PCS4 or PCS4i power control interface is receiving power and is running. When the unit is being reset, this LED blinks the appropriate number of times to indicate the reset mode that has been entered.

BReset button (recessed) — Use the tip of a Phillips screwdriver or a pointed stylus to press this recessed button to reset the unit in one of four Reset modes (see “Resetting the Unit” for details on reset modes and on using this button).

CPower control buttons 1-4— Press these buttons to switch power on and off to the output receptacle with the corresponding number on the rear panel. These buttons are

also used, along with the Set Reference buttons (D), to set the Full and Standby power thresholds.

DSet Reference (Power threshold) buttons — Press these buttons to set the indicator

LEDs for each receptacle to indicate whether the attached devices are operating at Full or Standby power level.

IPL T PCS4 • Front Panel Features and Operation

8

Image 14
Contents IPL T PCS4 IPL T PCS4iSafety Instructions English FCC Class a Notice Notifications Software CommandsConventions Used in this Guide Contents IPL T PCS4 Contents About this Guide FeaturesIntroduction About the IPL T PCS4Application Diagrams IPL T PCS4Connection Diagram for IPL T PCS4i Installation Rear Panels Installation OverviewRear Panels IPL T PCS4i Rear Panel 220 VACConfiguring the LAN Port Setting Up the LAN PortConnecting the Devices LAN Port CablingIPL T PCS4 Installation and Rear Panel Front Panel Features Operation Front Panel FeaturesSetting Power Level Reference Thresholds Setting Up the System Using the Front PanelSetting Up Power Control Setting the Full power threshold Standby If the receptacle Is set to Power level Receptacle FullNone and Not Set thresholds Grouping Receptacles Front panel Security Lockout Executive ModeLED lit Group Red power LED lit Group Clearing thresholdsActivation Resetting the UnitMode ResultHold the Reset button in until the Power LED blinks once Setting Up the Computer Using ARP Configuration ControlConfiguring the Hardware ARP-S Command Screen Setting Up the Computer Using a Web Browser Screen Showing the Ping CommandSetting up the computer for IP communication Subnet mask Default gateway Blank or Configuring the IPL T PCS4 using a web browser Example of a Default System SettingsUsing the Embedded Web Pages Password Prompt WindowViewing the System Status System Status WebIP settings ConfigurationSpecifying system settings Date and time settings Removing passwords Assigning passwordsTo assign passwords Entering e-mail addresses for alerts Mail Alerts Screen Upper PortionUpgrading firmware Managing receptaclesSwitching power to receptacles on and off Grouping receptaclesMonitoring the receptacles and setting the alarm Monitoring Settings sectionAlarm Relay Settings section Scheduling power to receptacles Scheduling an individual receptacleScheduling receptacles by day of the week All receptacles on and offOne receptacle, power on or off File ManagementOther file management functions Uploading files to the webAdding a directory Query Strings Custom Web PagesServer Side Includes SSIs Example of a Query String Command Code exampleURL Encoding Browser View of Previous Html Source CodeCharacters Hex Dec Reserved charactersUnsafe characters Custom Web Pages Device Power ControlAccessing and Using Telnet Port Troubleshooting Power ConnectionsSuccessful Ping Command Response Network ConnectionsDownloading Global Configurator Software Messages Initiated by the IPL T PCS4 SIS Programming ControlHost-to-Interface Communication Error Response References Password InformationError Responses Using the Command and Response Table Telnet Web BrowserSymbol Definitions ExampleX5@ X71 Command and Response Table for SIS Commands Power Receptacle Monitoring and Alarm FunctionsWeb Browser-specific Commands Password and Security Settings Set GMT offset24 View GMT offsetDirectory Commands Below Telnet text responses Ethernet control interface SpecificationsReference Material AC control interfaceAlarm relay control GeneralPart Numbers and Accessories Mounting the IPL T PCS4 InterfaceRack mounting procedure Mounting the IPL T PCS4 on a Rack ShelfUnder-desk Mounting Mounting the IPL T PCS4 under FurnitureGlossary 10/100Base-TDriver Power level reference threshold Subnet Asia Middle East USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Europe