Front Panel
Features and
Operation
This section contains a description of the IPL T PCS4 and IPL T PCS4i front panel features and instructions for setting up the PCS4 using the front panel. The following topics are discussed:
•Front Panel Features
•Setting Up the System Using the Front Panel
•Resetting the Unit
Front Panel Features
7 | 6 | 7 | 6 | 7 | 6 | 7 | 6 |
| IPL T PCS4 |
|
| 4 |
| 1 | 2 | 3 | |
1 | F | F | F | F |
R |
|
|
| |
| S | S | S | S |
| 2 |
| 3 |
|
SET REFERENCE
STANDBY FULL
100 |
|
LINK | 5 |
ACT |
|
4
Figure 7. IPL T PCS4 and IPL T PCS4i Front Panel
APower LED (green) — When this LED is lit, the PCS4 or PCS4i power control interface is receiving power and is running. When the unit is being reset, this LED blinks the appropriate number of times to indicate the reset mode that has been entered.
BReset button (recessed) — Use the tip of a Phillips screwdriver or a pointed stylus to press this recessed button to reset the unit in one of four Reset modes (see “Resetting the Unit” for details on reset modes and on using this button).
CPower control buttons
also used, along with the Set Reference buttons (D), to set the Full and Standby power thresholds.
DSet Reference (Power threshold) buttons — Press these buttons to set the indicator
LEDs for each receptacle to indicate whether the attached devices are operating at Full or Standby power level.
IPL T PCS4 • Front Panel Features and Operation | 8 |