Extron electronic IPL T PCS4i manual Below Telnet text responses

Page 59

Command

ASCII (Telnet)

URL Encoded (Web)

Response

(Host to Switcher)

(Host to Switcher)

(Switcher to Host)

 

 

 

 

File Listing Commands (continued)

 

 

List files from current directory

E LF}

W LF

(See below.)

and below

 

 

 

Telnet text responses:

path/directory/filename x date/time length] path/directory/filename x date/time length] path/directory/filename x date/time length]

...

space_remaining Bytes Left]

Web responses — HTML sample code:

Var file – new Array ();

File [1] = ‘filename1, date1, filesize1’;

File [2] = ‘filename2, date2, filesize2’;

...

File [n] = ‘filename n, date n, filesize n’;

File [n+1] = ‘space remaining, Bytes left’

NOTE:

The response to this command is the same as for the “List files from current directory” command (DF), except that

 

path/directory precedes filenames for files from subdirectories below the current directory.

 

Stream Files via Port 80

 

 

Load file to user flash memory24 28

Use a POST on port 80 followed by the delimited data to be written to the flash file

 

 

memory.

 

Retrieve files from user flash

Send a page GET on port 80 followed by WSF

Raw unprocessed data

memory24 28

 

 

in file

Example:

http://192.168.254.254/mypage.html?cmd=WSF

 

Stream Files via Telnet

 

 

Load file to user flash memory24 28

Retrieve file from user flash memory24 28

E + UF filesize, filename}

Raw unprocessed data in file up to file size

Upl]

E filename SF} 1B filename SF 0D Four bytes of file size + raw unprocessed data in file

Reset (Zap) and Erase Commands

Erase the user flash memory24 (files only)

Reset all device settings to factory default24

Absolute system reset24

E ZFFF}

W ZFFF

Zpf]

E ZXXX}

W ZXXX

Zpx]

E ZQQQ}

W ZQQQ

Zpq]

IPL T PCS4 • SIS Programming and Control 53

Image 59
Contents IPL T PCS4i IPL T PCS4Safety Instructions English FCC Class a Notice Notifications Software CommandsConventions Used in this Guide Contents IPL T PCS4 Contents About the IPL T PCS4 FeaturesIntroduction About this GuideIPL T PCS4 Application DiagramsConnection Diagram for IPL T PCS4i Installation Overview Installation Rear PanelsIPL T PCS4i Rear Panel 220 VAC Rear PanelsLAN Port Cabling Setting Up the LAN PortConnecting the Devices Configuring the LAN PortIPL T PCS4 Installation and Rear Panel Front Panel Features Front Panel Features OperationSetting Power Level Reference Thresholds Setting Up the System Using the Front PanelSetting Up Power Control Setting the Full power threshold Standby If the receptacle Is set to Power level Receptacle FullNone and Not Set thresholds Clearing thresholds Front panel Security Lockout Executive ModeLED lit Group Red power LED lit Group Grouping ReceptaclesResult Resetting the UnitMode ActivationHold the Reset button in until the Power LED blinks once Setting Up the Computer Using ARP Configuration ControlConfiguring the Hardware ARP-S Command Screen Screen Showing the Ping Command Setting Up the Computer Using a Web BrowserSetting up the computer for IP communication Subnet mask Default gateway Blank or Example of a Default System Settings Configuring the IPL T PCS4 using a web browserPassword Prompt Window Using the Embedded Web PagesSystem Status Web Viewing the System StatusIP settings ConfigurationSpecifying system settings Date and time settings Removing passwords Assigning passwordsTo assign passwords Mail Alerts Screen Upper Portion Entering e-mail addresses for alertsManaging receptacles Upgrading firmwareGrouping receptacles Switching power to receptacles on and offMonitoring Settings section Monitoring the receptacles and setting the alarmAlarm Relay Settings section Scheduling an individual receptacle Scheduling power to receptaclesAll receptacles on and off Scheduling receptacles by day of the weekFile Management One receptacle, power on or offOther file management functions Uploading files to the webAdding a directory Query Strings Custom Web PagesServer Side Includes SSIs Code example Example of a Query String CommandBrowser View of Previous Html Source Code URL EncodingCharacters Hex Dec Reserved charactersUnsafe characters Custom Web Pages Device Power ControlAccessing and Using Telnet Port Power Connections TroubleshootingNetwork Connections Successful Ping Command ResponseDownloading Global Configurator Software Messages Initiated by the IPL T PCS4 SIS Programming ControlHost-to-Interface Communication Error Response References Password InformationError Responses Telnet Web Browser Using the Command and Response TableExample Symbol DefinitionsX5@ X71 Power Receptacle Monitoring and Alarm Functions Command and Response Table for SIS CommandsWeb Browser-specific Commands Set GMT offset24 View GMT offset Password and Security SettingsDirectory Commands Below Telnet text responses AC control interface SpecificationsReference Material Ethernet control interfaceGeneral Alarm relay controlMounting the IPL T PCS4 Interface Part Numbers and AccessoriesMounting the IPL T PCS4 on a Rack Shelf Rack mounting procedureMounting the IPL T PCS4 under Furniture Under-desk Mounting10/100Base-T GlossaryDriver Power level reference threshold Subnet Europe USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East