Uploading files to the web page

The IPL T PCS4 has approximately 900 kbytes of space for user files to be uploaded. The Bytes Left field shows how much space remains for uploading files.

To upload files:

1.Select the File Management tab on the IPL T PCS4 web page.

2.On the File Management screen, click Browse to open a Windows file selection window.

3.On the file selection window, locate and select a file to upload. (Only one file at a time can be selected.) The file name and directory path appear in the Browse field on the File Management screen.

4.Click Upload File while the file is uploading, the button label changes to

Uploading... .

When the uploading is complete, the uploaded file name appears in the Files list with a time stamp showing GMT time, and the button returns to its original state. (Files are listed separately under headings of their extensions.)

Adding a directory

To add a directory or folder to the IPL T PCS4 file system:

1.Enter a name for the directory in the Dir: field, following the slash (/).

2.Click Add Dir.

3.With the directory name displayed, perform the uploading files procedure described in the previous section to add a file to the directory. The directory name appears at the top of the Files column, preceded by a slash (/).

If no files are added to the new directory, it is deleted.

To add more files to the directory, click the directory name to open it, then use the uploading files procedure. To exit the directory, click (root).

Other file management functions

On the File Management screen, you can also do the following:

Open and view an uploaded file by clicking on its name.

Delete an uploaded file by clicking the Delete button beside it.

Delete all uploaded files and directories by clicking the Delete All button.

IPL T PCS4 • HTML Configuration and Control 34

Image 40
Contents IPL T PCS4 IPL T PCS4iSafety Instructions English FCC Class a Notice Conventions Used in this Guide Software CommandsNotifications Contents IPL T PCS4 Contents Features IntroductionAbout this Guide About the IPL T PCS4Application Diagrams IPL T PCS4Connection Diagram for IPL T PCS4i Installation Rear Panels Installation OverviewRear Panels IPL T PCS4i Rear Panel 220 VACSetting Up the LAN Port Connecting the DevicesConfiguring the LAN Port LAN Port CablingIPL T PCS4 Installation and Rear Panel Front Panel Features Operation Front Panel FeaturesSetting Up Power Control Setting Up the System Using the Front PanelSetting Power Level Reference Thresholds Setting the Full power threshold None and Not Set thresholds If the receptacle Is set to Power level Receptacle FullStandby Front panel Security Lockout Executive Mode LED lit Group Red power LED lit GroupGrouping Receptacles Clearing thresholdsResetting the Unit ModeActivation ResultHold the Reset button in until the Power LED blinks once Configuring the Hardware Configuration ControlSetting Up the Computer Using ARP ARP-S Command Screen Setting Up the Computer Using a Web Browser Screen Showing the Ping CommandSetting up the computer for IP communication Subnet mask Default gateway Blank or Configuring the IPL T PCS4 using a web browser Example of a Default System SettingsUsing the Embedded Web Pages Password Prompt WindowViewing the System Status System Status WebSpecifying system settings ConfigurationIP settings Date and time settings To assign passwords Assigning passwordsRemoving passwords Entering e-mail addresses for alerts Mail Alerts Screen Upper PortionUpgrading firmware Managing receptaclesSwitching power to receptacles on and off Grouping receptaclesMonitoring the receptacles and setting the alarm Monitoring Settings sectionAlarm Relay Settings section Scheduling power to receptacles Scheduling an individual receptacleScheduling receptacles by day of the week All receptacles on and offOne receptacle, power on or off File ManagementAdding a directory Uploading files to the webOther file management functions Server Side Includes SSIs Custom Web PagesQuery Strings Example of a Query String Command Code exampleURL Encoding Browser View of Previous Html Source CodeUnsafe characters Reserved charactersCharacters Hex Dec Accessing and Using Telnet Port Device Power ControlCustom Web Pages Troubleshooting Power ConnectionsSuccessful Ping Command Response Network ConnectionsDownloading Global Configurator Software Host-to-Interface Communication SIS Programming ControlMessages Initiated by the IPL T PCS4 Error Responses Password InformationError Response References Using the Command and Response Table Telnet Web BrowserSymbol Definitions ExampleX5@ X71 Command and Response Table for SIS Commands Power Receptacle Monitoring and Alarm FunctionsWeb Browser-specific Commands Password and Security Settings Set GMT offset24 View GMT offsetDirectory Commands Below Telnet text responses Specifications Reference MaterialEthernet control interface AC control interfaceAlarm relay control GeneralPart Numbers and Accessories Mounting the IPL T PCS4 InterfaceRack mounting procedure Mounting the IPL T PCS4 on a Rack ShelfUnder-desk Mounting Mounting the IPL T PCS4 under FurnitureGlossary 10/100Base-TDriver Power level reference threshold Subnet USA, Canada, South America Japan Central America Europe, Africa, and the Middle China EastAsia Middle East Europe