Black Box IC026A-R2, IC026AE-R2 Controller Operation, Controller-Mode Serial to Ieee Operation

Page 32

RS-232IEEE 488 INTERFACE CONVERTER

4.Controller Operation

4.1Controller-Mode (Serial to IEEE) Operation

The IEEE Controller mode allows a serial RS-232 or RS-422 host device to send data to a single IEEE bus peripheral or to multiple peripherals if they occupy the same bus address. Applications include interfacing a listen-only or addressable IEEE printer/plotter to a serial printer port.

Once the interface converter has initialized itself after power-on, it waits for serial input data. When received, it addresses the selected IEEE device to listen with the following bus sequence:

ATNUNL,MTA,LAG,*ATN

The data received from the serial host is placed into a circular serial input buffer. Simultaneously, characters are removed from that buffer and sent to the IEEE bus device. The serial terminator(s), if present, are not sent.

Instead, the IEEE terminators are substituted and sent in their place.

As long as the serial input buffer is not empty, the interface converter will continue to send data from it to the IEEE bus device. If the serial input buffer becomes emptied, the interface converter will command the IEEE bus device to talk if one of the talk-back features is enabled. This allows the interface converter to be used as a controller with devices, such as plotters or instruments, that return status and other information to the host computer.

When the interface converter addresses the IEEE bus device to talk it uses the following bus sequence:

ATNUNL,MLA,TAG,*ATN

The interface converter then accepts data from the IEEE device and returns it to the host until the last selected IEEE terminator is detected. The IEEE bus terminators are replaced by the serial terminators, and these are then sent to the serial host.

If the IEEE device has been addressed to talk but does not respond or finish transmission by the time additional characters are received in the circular serial-input buffer, the talk sequence will be aborted to allow additional serial information to be sent to the IEEE device.

32

Image 32
Contents RS-232↔IEEE Interface Converter RS-232↔IEEE 488 Interface Converter Trademarks Used in this Manual RS-232↔IEEE 488 Interface Converter NOM Statement RS-232↔IEEE 488 Interface Converter Contents RS-232↔IEEE 488 Interface Converter Contents Serial Interface SpecificationsIEEE-488 Interface Specifications GeneralIntroduction DescriptionAbbreviations Configuration Getting StartedInspection Serial PortSW3 Serial Port Settings Switch SW1 Selecting the Serial Baud Rate Switch SW1 Selecting the Serial Word Length Data Bits Switch SW2 Selecting the Serial Parity Switch SW1 Selecting the Serial Handshake Switch SW2 Selecting the Serial Terminator Selecting Terminator SubstitutionSelecting the Mode Switch SW3 Selecting the Ieee Bus Terminator10. Switch SW2 Selecting the Mode Selecting the Ieee AddressFeature Selections Serial Interface 15. Selecting RS-232 or RS-422 Signal Levels RxD Receive Data-Input-Pin TxD Transmit Data-Output-PinClear To Send-Input-Pin Request To Send-Output-PinVtest Test Voltage-Output-Pin Gnd Ground-Pin+RxD Receive Data Plus-Input-Pin +TxD Transmit Data Plus-Output-PinRTS CTS General DSR RTS CTSGetting Started Controller Operation Controller-Mode Serial to Ieee OperationSerial and Ieee Terminator Substitution Talk-Back Features Ieee Address SelectionSwitch SW1 Enabling or Disabling Talk-Back on Terminator Switch SW2 Enabling or Disabling Talk-Back on Timeout 7470A SP1PA1000,1000PDPA1000,6000PUSP0Plotter Applications A PC-Based Graphics System SW3 MacPlot Configuration Screen Setting the Internal DIP Shorting Jumper for RS-422 SW3 Printer Applications Serial and Ieee Input Buffers Peripheral OperationPeripheral-Mode Operation Ieee Data Transfers Controlled BUS Data Transfers Serial-Poll Status-Byte Register DIO8 Ieee Input Buffer not EmptyRsv Not Defined-AlwaysSerial Input Buffer not Empty Ieee Input Buffer FullUse of Serial and Bus Terminators Ieee 488 Bus ImplementationUntalk UNT SW3 View for Ieee Address Selection General Structure Ieee 488 PrimerHistory RS-232↔IEEE 488 Interface Converter Send It to My Address DMMBus Management Lines Handshake Lines Data Valid DAVMultiline Commands Data LinesTalk Address Group TAG More on Service Requests Serial Poll Theory of Operation Address Device Part Number FunctionBoard Layout Component Layout of the Interface Converter’s MotherboardRED BLK Appendix A. Sample Dumb-Terminal Program CLSMultiline Messages SOHHow To Read the Chart Ascii CharacterIndex DIO1 DIO2 DIO3Index SW1 Copyright 1998. Black Box Corporation. All rights reserved