Kathrein MSK 24 manual Setup menu, Factory settings, Settings in the setup menu

Page 16

Starting up

Setup menu

The default setting (status of the MSK 24 when it is switched on) can be set in the setup menu.

Factory settings

Parameter

Setting

POWER ON

TV

LNB DC

OFF

LEVEL

dBìV

Low Level Mute

ON

Settings in the setup menu

Calling up the setup menu

POWER ON

TV=1 SAT=2 FM=3

1. Setup menu

 

 

LNB DC

 

OFF=1

ON=2

 

 

 

 

2. Setup menu

 

 

 

Level

 

dBµV=1

dBmV=2

 

 

 

 

3. Setup menu

 

 

 

CH: .07.

TV

LEV:____.__dBµV

 

 

 

 

4. Setup menu

 

 

LOW LEVEL MUTE

OFF=1

ON=2

 

 

 

 

Default setting

Press the [2ndF] and [SETUP] buttons.

Press button [1], [2] or [3] to select the appropriate TV, SAT or FM mode. Press [ENTER] to retain the current setting.

The following request appears:

Press button [1] or [2] to switch the LNB voltage supply on or off. Press [ENTER] to retain the current setting.

In the next menu press button [1] or [2] to set the measuring unit in which the level should be displayed. Press [ENTER] to retain the current setting.

In the next menu you are requested to set the mute function by pressing button [1] or [2]. Select "ON" to mute the MSK 24 as long as the input signal on the RF input is below 30 dBìV.

Press [ENTER] to retain the current setting.

If you have not altered the factory default setting, the information shown on the left is displayed.

As soon as you have set the low level mute, setup menu 4 is exited automatically and the default setting displayed.

16

Image 16
Contents Satellite / TV / Radio Test Receiver MSK Page Preface Validity of this manualContents Spectrum measurement Technical AppendixExplanation of symbols Safety instructionsGeneral Notes Parts suppliedHow it operates Overview of functions Block diagram of MSK Technical Data SAT10 V...20 V, max mA Operating and display elements Display elementsConnections right side LC displayOverview of the keyboard commands Connections RF input socketExternal DC voltage supply Scart outputSwitching on the receiver Switching off the receiverStarting up Software Accu LEV 48.5dBuVSetup menu Factory settingsSettings in the setup menu Setup menuBattery operation Mains and battery operationMains operation Sat measurement Standard Switch-OverPress 2ndF STD Frequency Display and Entering Frequency Overview of commands in Entering Frequency SATPress 1 5 0 8 E Nter Level Measurement Level Overflow and UnderflowLEV .dBuV LEV dBuV2ndF Scan Switch over to Scan operation Tracking SatellitesChange the measuring range of the bar display Calling up the Scan functionOverview of commands in Tracking Tracking for Single FrequenciesButton Frequency in MHz Bandwidth in kHz Audio Carrier FrequencyPress 2ndF SC LNB Voltage and 22 kHz / 60 Hz Switch-Over Overview of commands in LNB Voltage Example LNB14,0V 150mALNB voltage Button Press buttons 2ndF LNBExample LNB14,0V 22kHz 150mA DiSEqC Digital Satellite Equipment Control Parity bitOverview of commands in Framing Byte Press buttons 2ndF SAT-CTRLOverview of commands in Address Byte Hex byte DescriptionOverview of commands in Command Byte Sat measurement Overview of commands in Data Byte Orbit Switch position Data PositionOverview of commands in Simple DiSEqC Simple Tone Burst DiSEqCDiSEqC-SIMPLE Tone Burst SEC Vario-Satellite Equipment Control 2ndF SAT-CTRL Call up the V-SEC menuEnter the figures 0 to Enter the letters A...F ButtonTV measurement Overview of commands in Standard Switch-Over TV=BG 2=L 3=DK =I 5=MN 6=M1 Switch over to TV reception Switch to special channelChannel Display and Entering Channel Enter the channelThen 1 7 5 ./S 2 5 Enter Level Measurement TV LEV.dBuVLEV-RANGE2 TV Example Press buttons 2ndF LevelOverview of commands in Measuring Audio Carrier Frequency Audio Carrier Distance and LevelStandard Audio carrier Nicam SC 5.50MHz LEV -13.0dB LEV 58.5dBuVCalling up Measuring Audio Bit Error Rates Nicam Measuring Audio Bit Error RatesSC 5.85 MHz BER=2.145E-05 FM measurement 2ndF FMPress 2ndF FM Then 9 9 ./S 2 5 EnterFR104,80MHz FM LEV¯¯¯.¯dBuV Spectrum measurement Sat SpectrumTV Spectrum SAT-FullOverview of commands in TV Spectrum FM SpectrumTV full TV narrowChanging the battery MaintenanceCustomer service Technical Appendix Signal-to-noise distance+14.1 dB Command set for Kathrein matrix 9xx-series DiSEqC commands for Kathrein matricesCommand set for Kathrein matrix EXR Channel tables VHF-CCIR UHF-CCIRChannel and frequency table for L standard frequency in MHz VHF UHFIII Channel and frequency table for I standard frequency in MHz Technical Appendix Technical Appendix Technical Appendix Page 936.1997/ZWT/PF Technical data subject to change