Kathrein MSK 24 manual SEC Vario-Satellite Equipment Control, 2ndF SAT-CTRL Call up the V-SEC menu

Page 33

Sat measurement

V-SEC (Vario-Satellite Equipment Control)

V-SEC provides unidirectional communication between satellite receivers and peripheral components in a satellite receiving system and serves to control intelligent multiswitches with several inputs, coaxial relays or rotation systems.

V-SEC uses 8-bit data transfer by pulse width modulation of the 22 kHz carrier frequency. There is 8-bit data transfer from the test receiver to the peripheral equipment through the existing coaxial cable. The V-SEC control signals are assigned to the components by destination addresses. After output of the V-SEC data, standard signals of 14 V/18 V and 0/60 Hz/22 kHz are still available. Input of the code word is in hexadecimal code..

Overview of commands in V-SEC

ë

[2ndF] [SAT-CTRL]Call up the V-SEC menu

[0]...[9]

Enter the figures 0 to 9

[.] [0]...[5]

Enter the letters A...F

 

 

 

 

 

 

 

 

Button

 

Hex code

 

 

[.] [0]

 

A

 

 

[.] [1]

 

B

 

 

[.] [2]

 

C

 

 

[.] [3]

 

D

 

 

[.] [4]

 

E

 

 

[.] [5]

 

F

[-]or [+] Position cursor

[ENTER] Send the data packet

Exit the V-SEC menu by pressing [2ndF] twice.

Example

0

SAT-CTRL LNB=1

V-SEC=2 DiSEqC=3 SAT-CTRL menu

SAT-CTRL LNB=1

V-SEC=2 DiSEqC=3

V-SEC menu

Call up V-SEC and enter the A5 control command:

Press buttons [2ndF] [SAT-CTRL]

By pressing button [2] you can all up the V-SEC control.

Enter the data word in hexadecimal code, e.g. A5:

Press buttons [./S] [0] [5]

Press [ENTER] to send the control command. The > symbol indicates that the control command has been sent. The cursor can be positioned using the [-]and [+] buttons.

Overview of commands in V-SEC

See manufacturer's documentation on peripheral equipment.

33

Image 33
Contents Satellite / TV / Radio Test Receiver MSK Page Validity of this manual PrefaceContents Technical Appendix Spectrum measurementSafety instructions Explanation of symbolsGeneral Notes Parts suppliedHow it operates Overview of functions Block diagram of MSK SAT Technical Data10 V...20 V, max mA Display elements Operating and display elementsConnections right side LC displayOverview of the keyboard commands RF input socket ConnectionsExternal DC voltage supply Scart outputSwitching off the receiver Switching on the receiverStarting up Software Accu LEV 48.5dBuVFactory settings Setup menuSettings in the setup menu Setup menuMains and battery operation Battery operationMains operation Standard Switch-Over Sat measurementPress 2ndF STD Overview of commands in Entering Frequency SAT Frequency Display and Entering FrequencyPress 1 5 0 8 E Nter Level Overflow and Underflow Level MeasurementLEV .dBuV LEV dBuVTracking Satellites 2ndF Scan Switch over to Scan operationChange the measuring range of the bar display Calling up the Scan functionTracking for Single Frequencies Overview of commands in TrackingAudio Carrier Frequency Button Frequency in MHz Bandwidth in kHzPress 2ndF SC Overview of commands in LNB Voltage Example LNB14,0V 150mA LNB Voltage and 22 kHz / 60 Hz Switch-OverLNB voltage Button Press buttons 2ndF LNBExample LNB14,0V 22kHz 150mA Parity bit DiSEqC Digital Satellite Equipment ControlPress buttons 2ndF SAT-CTRL Overview of commands in Framing ByteHex byte Description Overview of commands in Address ByteOverview of commands in Command Byte Sat measurement Orbit Switch position Data Position Overview of commands in Data ByteOverview of commands in Simple DiSEqC Simple Tone Burst DiSEqCDiSEqC-SIMPLE Tone Burst 2ndF SAT-CTRL Call up the V-SEC menu SEC Vario-Satellite Equipment ControlEnter the figures 0 to Enter the letters A...F ButtonOverview of commands in Standard Switch-Over TV TV measurement=BG 2=L 3=DK =I 5=MN 6=M1 Switch to special channel Switch over to TV receptionChannel Display and Entering Channel Enter the channelThen 1 7 5 ./S 2 5 Enter LEV.dBuV Level Measurement TVPress buttons 2ndF Level LEV-RANGE2 TV ExampleAudio Carrier Distance and Level Overview of commands in Measuring Audio Carrier FrequencyStandard Audio carrier Nicam SC 5.50MHz LEV -13.0dB LEV 58.5dBuVNicam Measuring Audio Bit Error Rates Calling up Measuring Audio Bit Error RatesSC 5.85 MHz BER=2.145E-05 2ndF FM FM measurementPress 2ndF FM Then 9 9 ./S 2 5 EnterFR104,80MHz FM LEV¯¯¯.¯dBuV Sat Spectrum Spectrum measurementTV Spectrum SAT-FullFM Spectrum Overview of commands in TV SpectrumTV full TV narrowMaintenance Changing the batteryCustomer service Signal-to-noise distance Technical Appendix+14.1 dB DiSEqC commands for Kathrein matrices Command set for Kathrein matrix 9xx-seriesCommand set for Kathrein matrix EXR VHF-CCIR UHF-CCIR Channel tablesVHF UHF Channel and frequency table for L standard frequency in MHzIII Channel and frequency table for I standard frequency in MHz Technical Appendix Technical Appendix Technical Appendix Page 936.1997/ZWT/PF Technical data subject to change