Sat measurement
DiSEqC (Digital Satellite Equipment Control)
The DiSEqC system is used to control systems with extended control facilities. DiSEqC uses serial, bidirectional transmission with one master and one or more slaves. The data bits are formed by modulation of the pulse width of the available 22 kHz carrier and are superimposed with 600 mVss of the LNB remote voltage. The digital code words are made up of 8 data bits and one additional parity bit to detect transmission errors. Several code words form a DiSEqC command. Input of the code words is in hexidecimal code.
code words
Framing
P
Address
P
Command
P
Data
P
|
| parity bit | ||
| The MSK 24 can also transmit signals to DiSEqC 1.0 but it cannot | |||
| receive them. |
|
|
|
Overview of commands in DiSEqC |
|
|
| |
ë | [2ndF] | |||
[0]...[9] | Enter the code words in hexadecimal code 0...9 | |||
| [.] [0]...[5] | Enter the code words in hexadecimal code A...F | ||
|
|
|
|
|
|
| Button | Hex Code |
|
|
| [.] [0] | A |
|
|
| [.] [1] | B |
|
|
| [.] [2] | C |
|
|
| [.] [3] | D |
|
|
| [.] [4] | E |
|
|
| [.] [5] | F |
|
Move the cursor among the various code words: | |
| Framing, Address, Command and Data |
[.] [6] | Delete the entire command string up to the cursor |
| position |
[ENTER] Send the command string
Exit the DiSEqC menu by pressing [2ndF] twice.
26