Kathrein MSK 24 manual Example LNB14,0V 22kHz 150mA

Page 25

Sat measurement

Example

0

LNB:14,0V 22kHz 150mA

Note

+

Switch on the 22 kHz signal.

Press button [8].

LC display:

LNB voltage 14 V

Current consumption 150 mA

The 22 kHz signal is switched on.

By pressing button [8], you can switch off the 22 kHz signal.

By calling up another function, e.g. [2ndF] [CH-FRQ], you can exit the LNB menu automatically.

25

Image 25
Contents Satellite / TV / Radio Test Receiver MSK Page Validity of this manual PrefaceContents Technical Appendix Spectrum measurementSafety instructions Explanation of symbolsGeneral Notes Parts suppliedHow it operates Overview of functions Block diagram of MSK SAT Technical Data10 V...20 V, max mA Display elements Operating and display elementsConnections right side LC displayOverview of the keyboard commands RF input socket ConnectionsExternal DC voltage supply Scart outputSwitching off the receiver Switching on the receiverStarting up Software Accu LEV 48.5dBuVFactory settings Setup menuSettings in the setup menu Setup menuBattery operation Mains and battery operationMains operation Sat measurement Standard Switch-OverPress 2ndF STD Frequency Display and Entering Frequency Overview of commands in Entering Frequency SATPress 1 5 0 8 E Nter Level Overflow and Underflow Level MeasurementLEV .dBuV LEV dBuVTracking Satellites 2ndF Scan Switch over to Scan operationChange the measuring range of the bar display Calling up the Scan functionTracking for Single Frequencies Overview of commands in TrackingButton Frequency in MHz Bandwidth in kHz Audio Carrier FrequencyPress 2ndF SC Overview of commands in LNB Voltage Example LNB14,0V 150mA LNB Voltage and 22 kHz / 60 Hz Switch-OverLNB voltage Button Press buttons 2ndF LNBExample LNB14,0V 22kHz 150mA Parity bit DiSEqC Digital Satellite Equipment ControlPress buttons 2ndF SAT-CTRL Overview of commands in Framing ByteHex byte Description Overview of commands in Address ByteOverview of commands in Command Byte Sat measurement Orbit Switch position Data Position Overview of commands in Data ByteOverview of commands in Simple DiSEqC Simple Tone Burst DiSEqCDiSEqC-SIMPLE Tone Burst 2ndF SAT-CTRL Call up the V-SEC menu SEC Vario-Satellite Equipment ControlEnter the figures 0 to Enter the letters A...F ButtonTV measurement Overview of commands in Standard Switch-Over TV=BG 2=L 3=DK =I 5=MN 6=M1 Switch to special channel Switch over to TV receptionChannel Display and Entering Channel Enter the channelThen 1 7 5 ./S 2 5 Enter LEV.dBuV Level Measurement TVPress buttons 2ndF Level LEV-RANGE2 TV ExampleAudio Carrier Distance and Level Overview of commands in Measuring Audio Carrier FrequencyStandard Audio carrier Nicam SC 5.50MHz LEV -13.0dB LEV 58.5dBuVCalling up Measuring Audio Bit Error Rates Nicam Measuring Audio Bit Error RatesSC 5.85 MHz BER=2.145E-05 2ndF FM FM measurementPress 2ndF FM Then 9 9 ./S 2 5 EnterFR104,80MHz FM LEV¯¯¯.¯dBuV Sat Spectrum Spectrum measurementTV Spectrum SAT-FullFM Spectrum Overview of commands in TV SpectrumTV full TV narrowChanging the battery MaintenanceCustomer service Technical Appendix Signal-to-noise distance+14.1 dB Command set for Kathrein matrix 9xx-series DiSEqC commands for Kathrein matricesCommand set for Kathrein matrix EXR VHF-CCIR UHF-CCIR Channel tablesVHF UHF Channel and frequency table for L standard frequency in MHzIII Channel and frequency table for I standard frequency in MHz Technical Appendix Technical Appendix Technical Appendix Page 936.1997/ZWT/PF Technical data subject to change