Sat measurement
Overview of commands in Command Byte
| The MSK 24 can send commands in accordance with DiSEqC 1.0 but it | ||||||||
ë | cannot receive them. All commands that require DiSEqC 2.0 (to send and | ||||||||
receive) are shown in grey in the table. |
|
|
|
|
| ||||
Commands shown in | bold type are used | preferentially | for Kathrein | ||||||
| switching matrices. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
| Hex | Command | Description |
|
|
|
| Number of | |
| byte |
|
|
|
|
|
|
| data bytes |
| 00 | Reset | Reset DiSEqC microcontroller |
| - | ||||
| 01 | Clr Reset | Clear reset flag |
|
|
|
| - | |
| 02 | Standby | Switch off the peripheral power |
| - | ||||
|
|
| supply unit |
|
|
|
|
| |
| 03 | Power on | Switch on the peripheral power |
| - | ||||
|
|
| supply unit |
|
|
|
|
| |
| 04 | Set Content | Set the contention flag |
|
| - | |||
| 05 | Contend | Feedback only if the contention |
| - | ||||
|
|
| flag has been set |
|
|
|
|
| |
| 06 | Clr Content | Clear contention flag |
|
|
| - | ||
| 07 | Address | Feedback only if the contention |
| - | ||||
|
|
| flag has not been set |
|
|
|
| ||
| 08 | Move C | Change | address | if | contention |
| 1 | |
|
|
| flag has been set |
|
|
|
|
| |
| 09 | Move | Change | address | if | contention |
| 1 | |
|
|
| flag has not been set |
|
|
|
| ||
| 10 | Status | Read status register flags |
|
| - | |||
| 11 | Config | Read configuration flags |
|
| - | |||
| 14 | Switch 0 | Read switching | status | flags |
| - | ||
|
|
| (Committed Port) |
|
|
|
|
| |
| 15 | Switch 1 | Read | switching | state | flags |
| - | |
|
|
| (uncommitted port) |
|
|
|
|
| |
| 16 | Switch 2 | Expansion option |
|
|
|
| - | |
| 17 | Switch 3 | Expansion option |
|
|
|
| - | |
| 20 | Set LO | Call up the low local oscillator |
| - | ||||
|
|
| frequency |
|
|
|
|
| |
| 21 | Set VR | Call up vertical polarization or |
| - | ||||
|
|
| circular | polarization | with | right |
|
| |
|
|
| rotation |
|
|
|
|
|
|
| 22 | Set Pos A | Select satellite position A |
|
| - | |||
| 23 | Set S0A | Select switch option A |
|
| - | |||
| 24 | Set Hi | Call up the high local |
| - | ||||
|
|
| oscillator frequency |
|
|
|
| ||
| 25 | Set HL | Call up vertical polarization or |
| - | ||||
|
|
| circular | polarization | with | left |
|
| |
|
|
| rotation |
|
|
|
|
|
|
| 26 | Set Pos B | Select satellite position B |
|
| - | |||
| 27 | Set S0B | Select switch option B |
|
| - | |||
| 28 | Set S1A | Call up matrix S1 input A (input |
| - | ||||
|
|
| B inactive) |
|
|
|
|
| |
| 29 | Set S2A | Call up matrix S2 input A (input |
| - |
29