TV measurement

Channel Display and Entering Channel

To measure the level of a received TV signal, you must first enter the desired channel.

The following channels can be set:

Band I / III CH 01 to CH 12 in the 7 MHz raster

Band IV / V CH 21 to CH 70 in the 8 MHz raster

Special channel

S 01 to S 20 in the 7 MHz raster

Special channel

S 21 to S 41 in the 8 MHz raster

The information refers only to the factory-preset B/G standard. You can find information for other standards in the Technical Appendix.

Overview of commands in Entering Channel (TV)

ë

Example

0

CH:S.11.TV LEV: 62.5dBuV

Note

+

[SAT/TV]

Switch over to TV reception

[0]...[9]

Enter the channel

[./S]

Switch to special channel

[+]and [-]Alter the channels gradually

Enter channel S11:

Press [./S] [1] [1].

LC display:

Special channel: S 11

Level: 62.5 dBìV

Mode: TV

Make sure that the correct standard has been set. The B/G standard is the default setting.

35

Image 35
Contents Satellite / TV / Radio Test Receiver MSK Page Validity of this manual PrefaceContents Technical Appendix Spectrum measurementParts supplied Explanation of symbolsSafety instructions General NotesHow it operates Overview of functions Block diagram of MSK SAT Technical Data10 V...20 V, max mA LC display Operating and display elementsDisplay elements Connections right sideOverview of the keyboard commands Scart output ConnectionsRF input socket External DC voltage supplySoftware Accu LEV 48.5dBuV Switching on the receiverSwitching off the receiver Starting upSetup menu Setup menuFactory settings Settings in the setup menuMains operation Mains and battery operationBattery operation Press 2ndF STD Standard Switch-OverSat measurement Press 1 5 0 8 E Nter Overview of commands in Entering Frequency SATFrequency Display and Entering Frequency LEV dBuV Level MeasurementLevel Overflow and Underflow LEV .dBuVCalling up the Scan function 2ndF Scan Switch over to Scan operationTracking Satellites Change the measuring range of the bar displayTracking for Single Frequencies Overview of commands in TrackingPress 2ndF SC Audio Carrier FrequencyButton Frequency in MHz Bandwidth in kHz Press buttons 2ndF LNB LNB Voltage and 22 kHz / 60 Hz Switch-OverOverview of commands in LNB Voltage Example LNB14,0V 150mA LNB voltage ButtonExample LNB14,0V 22kHz 150mA Parity bit DiSEqC Digital Satellite Equipment ControlPress buttons 2ndF SAT-CTRL Overview of commands in Framing ByteHex byte Description Overview of commands in Address ByteOverview of commands in Command Byte Sat measurement Simple Tone Burst DiSEqC Overview of commands in Data ByteOrbit Switch position Data Position Overview of commands in Simple DiSEqCDiSEqC-SIMPLE Tone Burst Enter the letters A...F Button SEC Vario-Satellite Equipment Control2ndF SAT-CTRL Call up the V-SEC menu Enter the figures 0 to=BG 2=L 3=DK =I 5=MN 6=M1 Overview of commands in Standard Switch-Over TVTV measurement Enter the channel Switch over to TV receptionSwitch to special channel Channel Display and Entering ChannelThen 1 7 5 ./S 2 5 Enter LEV.dBuV Level Measurement TVPress buttons 2ndF Level LEV-RANGE2 TV ExampleSC 5.50MHz LEV -13.0dB LEV 58.5dBuV Overview of commands in Measuring Audio Carrier FrequencyAudio Carrier Distance and Level Standard Audio carrier NicamSC 5.85 MHz BER=2.145E-05 Nicam Measuring Audio Bit Error RatesCalling up Measuring Audio Bit Error Rates Then 9 9 ./S 2 5 Enter FM measurement2ndF FM Press 2ndF FMFR104,80MHz FM LEV¯¯¯.¯dBuV SAT-Full Spectrum measurementSat Spectrum TV SpectrumTV narrow Overview of commands in TV SpectrumFM Spectrum TV fullCustomer service MaintenanceChanging the battery +14.1 dB Signal-to-noise distanceTechnical Appendix Command set for Kathrein matrix EXR DiSEqC commands for Kathrein matricesCommand set for Kathrein matrix 9xx-series VHF-CCIR UHF-CCIR Channel tablesVHF UHF Channel and frequency table for L standard frequency in MHzIII Channel and frequency table for I standard frequency in MHz Technical Appendix Technical Appendix Technical Appendix Page 936.1997/ZWT/PF Technical data subject to change