TV measurement
Standard Switch-Over
In the TV mode the MSK 24 can measure the following standards:
∙B/G standard
∙L standard
∙D/K standard
∙I standard
∙M/N standard
∙M1 standard (Japan)
Overview of commands in Standard Switch-Over (TV)
ë | [2ndF] [STD] Call up standard | ||
[0]...[6] | Select standard | ||
|
Example
0
1=ANALOG
2=DIGITAL(DVB)
1. Standard menu
Call up B/G analogue standard: Press [2ndF] [STD].
LC display:
∙1 = Analogue reception
∙2 = DVB reception
1=BG 2=L 3=DK
4=I 5=MN 6=M1
2. Standard menu
Note
+
Press button [1].
The following menu now appears:
∙1 = B/G Standard - 2 = L standard - 3 = D/K standard D/K, etc.
Press button [1]. The receiver is now set to analogue reception for B/G standard.
Make sure that the selected standard is retained when the receiver is switched off.
34