Error | Sub- | Error | Subcode | Compo- | Corrective Action |
Code | code | Description | Description | nent |
|
(hex) |
|
|
|
|
|
| 13 |
| Drive interface 24V |
|
|
|
|
| fuse overload (F3) |
|
|
|
|
|
|
|
|
| 14 |
| SCSI Converter SE |
|
|
|
|
| term pwr fuse overload |
|
|
|
|
| (F1) to drive modules |
|
|
|
|
|
|
|
|
| 15 |
| SCSI Converter SE |
|
|
|
|
| term pwr fuse overload |
|
|
|
|
| (F1) to drive modules |
|
|
|
|
|
|
|
|
| 16 |
| SCSI Converter LVD |
|
|
|
|
| term pwr fuse overload |
|
|
|
|
| (F2) to bus 1 or bus 3 |
|
|
|
|
|
|
|
|
| 17 |
| SCSI Converter LVD |
|
|
|
|
| term pwr fuse overload |
|
|
|
|
| (F2) to bus 2 |
|
|
|
|
|
|
|
|
| 18 |
| Magazine interface |
|
|
|
|
| 3.3V regulator over- |
|
|
|
|
| load (U4) |
|
|
|
|
|
|
|
|
| 19 |
| Magazine interface |
|
|
|
|
| access door solenoid |
|
|
|
|
| 24V fuse overload (F2) |
|
|
|
|
|
|
|
|
| 20 |
| Magazine interface flip- |
|
|
|
|
| per 24V fuse overload |
|
|
|
|
| (F3) |
|
|
|
|
|
|
|
|
| 21 |
| Power distribution fuse |
|
|
|
|
| 1 overload +5V inter- |
|
|
|
|
| face CJ7 for Power to |
|
|
|
|
| Mag. circuit board |
|
|
|
|
|
|
|
|
| 22 |
| Power distribution fuse |
|
|
|
|
| 2 overload +5V inter- |
|
|
|
|
| face CJ7 for Power to |
|
|
|
|
| RMI circuit board |
|
|
|
|
|
|
|
|
| 23 |
| Power distribution fuse |
|
|
|
|
| 3 overload +24V inter- |
|
|
|
|
| face CJ7 for Power to |
|
|
|
|
| Mag. circuit board |
|
|
|
|
|
|
|
|
| 24 |
| Power distribution fuse |
|
|
|
|
| 4 overload +24V inter- |
|
|
|
|
| face CJ7 for Cabinet |
|
|
|
|
| cooling fans |
|
|
|
|
|
|
|
|
14 | 1 | Circuit board fail | Comm error with VP |
|
|
|
|
| decoder circuit board |
|
|
|
|
|
|
|
|
Plasmon D875 - D2175 User Manual | Appendix D |
Document Revision E | Page 67 |