Error | Sub- | Error | Subcode | Compo- | Corrective Action |
Code | code | Description | Description | nent |
|
(hex) |
|
|
|
|
|
| 4 |
| Terminated SCSI task |
|
|
|
|
| or completion status not |
|
|
|
|
| started during a store |
|
|
|
|
| tray retry |
|
|
|
|
|
|
|
|
61 | 1 | Lift Position fail | Destination encoder | Bad Lift | Replace lift motor |
|
|
| count out of boundaries | motor/ |
|
|
|
|
| encoder |
|
|
|
|
|
|
|
| 2 |
| Position lift destination |
|
|
|
|
| not reached |
|
|
|
|
|
|
|
|
| 3 |
| Destination lift position |
|
|
|
|
| is invalid |
|
|
|
|
|
|
|
|
| 4 |
| Position retry aborted |
|
|
|
|
|
|
|
|
63 | 1 | Lift blocked | VP sensor blocked, last | Tray out of | Reseat tray in slot, replace |
|
|
| col Blocked is set | slot, Bad Vp | VP |
|
|
|
|
|
|
| 2 |
| Lift is not in column of a | Bad Vp sen- |
|
|
|
| blocked VP sensor dur- | sor, tray out |
|
|
|
| ing initialization | slot |
|
|
|
|
|
|
|
| 3 |
| VP or Tray sensor | Obstruction |
|
|
|
| blocked after storing | in slot |
|
|
|
| media, during initializa- |
|
|
|
|
| tion. |
|
|
|
|
|
|
|
|
| 4 |
| Blocked VP sensor not |
|
|
|
|
| in the column clear |
|
|
|
|
| attempt being tried |
|
|
|
|
|
|
|
|
| 5 |
| VP or Tray sensor | Obstruction |
|
|
|
| blocked after store or | in slot or |
|
|
|
| load, during clear | drive |
|
|
|
| attempt. |
|
|
|
|
|
|
|
|
| 6 |
| VP or Tray sensor | Obstruction |
|
|
|
| blocked after store | in slot |
|
|
|
| operation (move from |
|
|
|
|
| lift) |
|
|
|
|
|
|
|
|
| 7 |
| VP or Tray sensor | Obstruction |
|
|
|
| blocked trying to return | in slot, align- |
|
|
|
| a tray to its last known | ment |
|
|
|
| location. |
|
|
|
|
|
|
|
|
69 | 1 | Pivot align fail | Too much gear back- | Pivot motor | Realign or replace pivot |
|
|
| lash / gear is loose dur- | mounting | motor |
|
|
| ing home pivot attempt |
|
|
|
|
|
|
|
|