Error | Sub- | Error | Subcode | Compo- | Corrective Action |
Code | code | Description | Description | nent |
|
(hex) |
|
|
|
|
|
15 | 1 | Can time out - | CAN time out checking | Drive inter- | Replace drive interface circuit |
|
| drive | drive interface | face circuit | board or CAN cables |
|
|
|
| board, CAN |
|
|
|
|
| cables |
|
|
|
|
|
|
|
| 2 |
| CAN time out getting |
|
|
|
|
| drive status |
|
|
|
|
|
|
|
|
| 3 |
| CAN time out getting |
|
|
|
|
| SCSI converter status |
|
|
|
|
|
|
|
|
| 4 |
| CAN time out getting |
|
|
|
|
| fan tach values |
|
|
|
|
|
|
|
|
| 5 |
| CAN time out setting |
|
|
|
|
| drive loaded |
|
|
|
|
|
|
|
|
| 6 |
| CAN time out setting |
|
|
|
|
| drive unloaded |
|
|
|
|
|
|
|
|
| 7 |
| CAN time out setting |
|
|
|
|
| drive id |
|
|
|
|
|
|
|
|
| 8 |
| CAN time out powering |
|
|
|
|
| on drive |
|
|
|
|
|
|
|
|
| 9 |
| CAN time out getting |
|
|
|
|
| drive type |
|
|
|
|
|
|
|
|
| 10 |
| CAN time out powering |
|
|
|
|
| off drive |
|
|
|
|
|
|
|
|
| 11 |
| CAN time out clamping |
|
|
|
|
| drive |
|
|
|
|
|
|
|
|
| 12 |
| CAN time out unclamp- |
|
|
|
|
| ing drive |
|
|
|
|
|
|
|
|
| 13 |
| CAN time out complet- |
|
|
|
|
| ing clamp/unclamp |
|
|
|
|
| drive |
|
|
|
|
|
|
|
|
| 14 |
| CAN time out isolating |
|
|
|
|
| bus |
|
|
|
|
|
|
|
|
| 15 |
| CAN time out restoring |
|
|
|
|
| bus |
|
|
|
|
|
|
|
|
| 16 |
| CAN time out blinking |
|
|
|
|
| LED for drive status |
|
|
|
|
|
|
|
|
| 17 |
| CAN time out turning |
|
|
|
|
| off LED for drive status |
|
|
|
|
|
|
|
|
Plasmon D875 - D2175 User Manual | Appendix D |
Document Revision E | Page 69 |