Error | Sub- | Error | Subcode | Compo- | Corrective Action |
Code | code | Description | Description | nent |
|
(hex) |
|
|
|
|
|
| 3 |
| 24V out of range during |
|
|
|
|
| check main circuit |
|
|
|
|
| board cable check |
|
|
|
|
|
|
|
|
19 | 1 | Power supply fail | One of the power sup- | Power sup- | Replace power supply, check |
|
|
| ply has been removed | ply, or supply | supply cable |
|
|
|
| cable |
|
|
|
|
|
|
|
| 2 |
| Power supply fan has |
|
|
|
|
| failed |
|
|
|
|
|
|
|
|
| 3 |
| Power supply power |
|
|
|
|
| failure |
|
|
|
|
|
|
|
|
1A | 1 | SCSI bus isola- | Time out waiting for iso- |
|
|
|
| tion | late bus command to |
|
|
|
|
| complete |
|
|
|
|
|
|
|
|
| 2 |
| Time out waiting for iso- |
|
|
|
|
| late bus to complete |
|
|
|
|
| while restoring bus |
|
|
|
|
|
|
|
|
1B | 1 | Too few power | More than one drive |
| Add power supply |
|
| supplies | interface board and |
|
|
|
|
| only one power supply |
|
|
|
|
|
|
|
|
22 | 1 | Bus already iso- | Service drives, isolate |
|
|
|
| lated | request and bus |
|
|
|
|
| already isolated |
|
|
|
|
|
|
|
|
| 2 |
| Restore drives, isolate |
|
|
|
|
| request and bus |
|
|
|
|
| already isolated |
|
|
|
|
|
|
|
|
23 | 1 | Bus not isolated | Service drives, |
|
|
|
|
| late request and bus |
|
|
|
|
| not isolated |
|
|
|
|
|
|
|
|
| 2 |
| Restore drives, |
|
|
|
|
| late request and bus |
|
|
|
|
| not isolated |
|
|
|
|
|
|
|
|
31 | 1 | Drive not | Positioning to drive | Drive inter- | Replace cables or drive inter- |
|
| installed |
| face cables | face circuit board or configure |
|
|
|
|
| in drive |
|
|
|
|
|
|
| 3 |
| Checking a move from |
|
|
|
|
| a drive |
|
|
|
|
|
|
|
|
| 4 |
| Checking a move to a |
|
|
|
|
| drive |
|
|
|
|
|
|
|
|
Plasmon D875 - D2175 User Manual | Appendix D |
Document Revision E | Page 71 |