Error | Sub- | Error | Subcode | Compo- | Corrective Action |
Code | code | Description | Description | nent |
|
(hex) |
|
|
|
|
|
6A | 1 | Pivot Fail | Pivot is loosing posi- | Offsets | Run offsets |
|
|
| tion accuracy, not on |
|
|
|
|
| alignment flag verifying |
|
|
|
|
| pivot position |
|
|
|
|
|
|
|
|
| 2 |
| Outside allowed pivot |
|
|
|
|
| soft deviation steps, but |
|
|
|
|
| position will succeed |
|
|
|
|
|
|
|
|
| 3 |
| Outside allowed pivot |
|
|
|
|
| soft deviation steps, but |
|
|
|
|
| position will succeed |
|
|
|
|
|
|
|
|
| 4 |
| Outside allowed pivot |
|
|
|
|
| hard deviation steps, |
|
|
|
|
| position will fail |
|
|
|
|
|
|
|
|
| 5 |
| Destination pivot value |
|
|
|
|
| out of range |
|
|
|
|
|
|
|
|
| 6 |
| Pivot position failed to |
|
|
|
|
| be reached (time out) |
|
|
|
|
|
|
|
|
70 | 1 | Mag door open | Time out waiting for | Mag inter- | Replace Mag circuit board or |
|
| fail | mag door status | face circuit | solenoid, check mechanical |
|
|
|
| board, mag | obstruction |
|
|
|
| solenoid |
|
|
|
|
|
|
|
71 | 1 | Mag access | Mag door open during |
| Close door |
|
| door is open | initialization |
|
|
|
|
|
|
|
|
| 2 |
| Mag door opened in |
|
|
|
|
| online mode (not by |
|
|
|
|
| solenoid) |
|
|
|
|
|
|
|
|
72 | 1 | Door open pre- | SCSI prevent com- |
| Issue SCSI allow from host |
|
| vented | mand was issued by |
|
|
|
|
| host, mag door opening |
|
|
|
|
| is not allowed |
|
|
|
|
|
|
|
|
74 | 1 | Rear door is | Background check of |
| Close Rear door |
|
| open | rear door open during |
|
|
|
|
| initialization |
|
|
|
|
|
|
|
|
| 2 |
| Background check of |
|
|
|
|
| rear door open during |
|
|
|
|
| online operation |
|
|
|
|
|
|
|
|
| 3 |
| Rear door open during |
|
|
|
|
| online test ready check |
|
|
|
|
|
|
|
|
Plasmon D875 - D2175 User Manual | Appendix D |