Plasmon D875, D2175 user manual Figuration

Page 75

Error

Sub-

Error

Subcode

Compo-

Corrective Action

Code

code

Description

Description

nent

 

(hex)

 

 

 

 

 

 

2

 

Drive is clamped, can

Drive, drive

Replace Drive, drive cables

 

 

 

not unclamp (checking

cables

 

 

 

 

move to a drive)

 

 

 

 

 

 

 

 

38

1

Drive in service

In service state,

 

Follow operating instructions

 

 

state

attempting to turn drive

 

 

 

 

 

off in maint menu

 

 

 

 

 

 

 

 

 

2

 

In service state,

 

 

 

 

 

attempting to turn drive

 

 

 

 

 

on in maint menu

 

 

 

 

 

 

 

 

 

3

 

In service state,

 

 

 

 

 

attempting to put drive

 

 

 

 

 

in service state via

 

 

 

 

 

SCSI command

 

 

 

 

 

 

 

 

39

1

Drive not in ser-

Restoring drives, not in

 

Follow operating instructions

 

 

vice state

a service state

 

 

 

 

 

 

 

 

3F

1

Drive Addr con-

Address conflict with

 

Correct address in setup con-

 

 

flict

changer

 

figuration

 

 

 

 

 

 

 

2

 

Address conflict with

 

 

 

 

 

another drive

 

 

 

 

 

 

 

 

40

1

Not supported

Attempt to put drive in

 

 

 

 

by bus config.

service state via SCSI,

 

 

 

 

 

drive not supported by

 

 

 

 

 

current bus config.

 

 

 

 

 

 

 

 

 

2

 

Attempt to restore drive

 

 

 

 

 

via SCSI, drive not sup-

 

 

 

 

 

ported by current bus

 

 

 

 

 

config.

 

 

 

 

 

 

 

 

41

1

Drives overheat-

Warning for an over

Cabinet

Check room temp

 

 

ing

heating drive

Temp

 

 

 

 

 

 

 

42

1

Drives shut-

Drive will be shutdown

Cabinet

Check room temp

 

 

down - heat

due to overtemp condi-

Temp

 

 

 

 

tion, alert host of 90 sec

 

 

 

 

 

delay before shutdown

 

 

 

 

 

 

 

 

43

1

Low fan speed-

Warning for low fan

Fan

Replace fan

 

 

drive

speed in a drive module

 

 

 

 

 

 

 

 

44

1

Drive shutdown-

Drive will be shutdown

Fan

Replace fan

 

 

fan

due to fan failure, alert

 

 

 

 

 

host of 90 sec delay

 

 

 

 

 

before shutdown

 

 

 

 

 

 

 

 

Plasmon D875 - D2175 User Manual

Appendix D

Document Revision E

Page 73

Image 75
Contents Plasmon Enterprise Series Page Trademark Notices PrefaceCopyright DisclaimerRevision Date Description Revision HistoryConventions Used Product Warranty Table of Contents Menu System SpecificationsSafety Agency Standard Error Codes Index Contacting PlasmonList of Figures List of Figures Document Revision E List of Tables List of Tables Document Revision E General Information Chapter Product OverviewMedia Type Capacity MagazineMedia and Magazine Handling Front Panel Display Front Access DoorMagazine Access Door Major Hardware ComponentsDrive Modules Main Power Switch and Power CablePower Supplies Import/Export Port I/ERotation Station Rear Access DoorLift Assembly Media Transport Element MTELibrary Position Chapter Library InstallationGetting Started Unpacking the LibraryPower Cable and Power Switch Library EnvironmentRemoving Internal Packing Material Removing the Packing Foam from the MTE Library InitializationScsi Connection Connecting the Scsi InterfaceMagazine Slots Loading MediaLED State Description Model Number of Slots Column Numbers Identifying Storage SlotsExpansion Bay Installation a D1525 D2175 Bay InstallationExpansion Bay Installation b Expansion Bay Installation c Expansion Bay Installation e Packing the D875 D2175 Libraries a Library Packing InstructionsPacking the D875 D2175 Libraries b Packing the D875 D2175 Libraries e Place cardboard sleeve over library, and place lid on top Packing Instructions D1525 D2175 Expansion Bays Expansion Bay Packing b Expansion Bay Packing d Expansion Bay Packing f Expansion Bay Packing h Expansion Bay Packing j Library Installation Document Revision E Navigating the Menu System Chapter Menu SystemLCD symbol Meaning Symbol Meaning Power Up Menu OptionsMain Menu Overview Main Menu OverviewAaaa Menu Selection DescriptionLibrary Status Menu Options Library Status Menu OverviewLibrary Status Menu Selections Commands which affect library operations are recorded Set Up Library Menu Options Set Up Library Menu OverviewSet Up Library Menu Selections Scsi commands which affect library operations are recorded Menu System Document Revision E Appendix a Specifications Overall Library SpecificationsSpecification D875 D1525 D2175 Library One expansion bay Two expansion bays Specification LimitsScsi Cable Length Power Cable SpecificationScsi Cable Specification Scsi Cables and ConnectorsAppendix a Document Revision E Scsi Bus Configurations Single Bus ConfigurationAppendix B Scsi BUS Information Dual Bus Configuration Dual Bus ConfigurationTriple Bus Configuration Triple Bus ConfigurationDevice Bus Config Scsi ID ConfigurationBer of Drives Drive CombinationsDrive Bus Maximum Total Combination NumberAppendix B Document Revision E Australia / New Zealand Appendix C Safety Agency StandardFCC Notice Industry Canadian Notice per ICES-003Taiwan Bsmi Class a Warning Statement Laser Safety Notice Lithium BatteryCdrh Regulations Press ? to re-display the error Appendix D Error CodesD875 D2175 Error Codes To Access door solenoid Appendix D Document Revision E Appendix D Appendix D Document Revision E Appendix D Appendix D Document Revision E Restore drives, un-iso Appendix D Document Revision E Figuration MTE Or completion status not Appendix D Document Revision E Appendix D Appendix D Document Revision E Appendix D FS Eeprom Appendix D Appendix D Document Revision E Appendix D Appendix D Document Revision E Rear IndexIndex Document Revision E Technical Support in Europe, Middle East, and Africa Technical Support in the United States