54
SGD Wireless Commands
weblink.ip.conn[12].maximum_simultaneous_ connections
weblink.ip.conn[12].maximum_simultaneous_ connections
Description This command indicates the maximum number of simultaneous connections that can be initiated by the printer.
Via the main connection (the original connection initiated by the printer to the remote server), the remote server can request that additional connetions from the printer be initated (e.g. a connection that supports only JSON SGDs, one that behaves similar to the RAW TCP port.
The server is free to request as many as it thinks it needs, but the printer will prevent more than N number of connections, where N is the value of this command.
^JUF, ^JUS, ^JUN, ^JUA, and device.restore_defaults do not have any affect on this setting.
Supported Devices
•iMZ 220™, iMZ 320™
•QLn220™, QLn320™, QLn420™
•ZT210™, ZT220™, ZT230™
Type setvar, getvar
Commands | Details |
|
|
setvar | This command sets the maximum number of connections. |
Format:
•! U1 setvar "weblink.ip.conn1.maximum_simultaneous_connections" "value"
•! U1 setvar "weblink.ip.conn2.maximum_simultaneous_connections" "value"
Values: Any integer from
Default: "10"
getvar | This command retrieves the maximum set number of connections. |
Format:
•! U1 getvar "weblink.ip.conn1.maximum_simultaneous_connections"
•! U1 getvar "weblink.ip.conn2.maximum_simultaneous_connections"
Example • This example sets the conn1 maximum connections to 3.
! U1 setvar "weblink.ip.conn1.maximum_simultaneous_connections" "3"
| 1/20/15 |