weblink.ip.conn[12].test.location

Example • The test connection can assist the user in several ways/scenarios:

1.If the test.test_on value is set to "failure", any time the main weblink

(conn[12].location) connection fails to connect then the test.location URL will be used. In this situation, an attempt will be made to contact the remote URL in test.location, using authentication and proxy configuration that is specified by the main connection.

2.If the test.test_on value is set to "interval" an attempt will be made to contact the remote URL in test.location every test.retry_interval seconds, using authentication and proxy configuration that is specified by the main connection.

3.If the test.test_on value is set to "both", then scenario 1 and 2 will both occur. This is useful for users who will use an HTTP connection to move through their firewall - and thereafter frequently refresh the connection to indicate to their firewall that there is still activity for the purpose of keeping the connection alive.

59

1/20/15

P1071336-002

Image 59
Contents Soti Page 20/15 P1071336-002 P1071336-002 20/15 Contents WebLink Set/Get/Do Commands About This Document How This Document Is Organized Who Should Use This DocumentIcons Used Document ConventionsAbout This Document Introduction Supported Operating Systems What Soti MobiControl Connector DoesOverview Supported PrintersInstallation Minimum System Requirements Installing in a Windows Operating SystemInstall a MobiControl Server Installation StepsInstallation My Documents\zebracerts\ Click Finish Install Software Installation Mypasserver.com Mypc.company.lan Enter the password selected in on Installation Test a Printer Enable Printer DiscoveryInstallation Installation Installation Installation Set Up Printers Discover Your Printers Configuring Printers with WebLink When a Proxy Server is Part of the Network Configuration Configuring WeblinkBasic Configuration To remove authentication credentials issue the following When Http Authentication is NecessaryDifference Between Conn1 and Conn2 Additional Firewall ConfigurationEnable Logging Navigating the Log Output Configuring Printers with WebLink Troubleshooting Locating the Soti MobiControl Connector Log File Installation ErrorsRestarting the Soti MobiControl Connector Value that it was last set to. This does not mean the value SSL/TLS Certificate ErrorsIncorrect. Check that the printer’s date and time rtc.date Communication Other Typical ErrorsTroubleshooting Http Messages Troubleshooting WebLink Set/Get/Do Commands Introduction to SGD Commands Weblink.enable Weblink.ip.conn12.authentication.add Entries Weblink.ip.conn12.authentication.entries Weblink.ip.conn12.authentication.remove Weblink.ip.conn12.enable Weblink.ip.conn12.location Weblink.ip.conn12.maximumsimultaneous connections Weblink.ip.conn12.proxy This command assigns the URL of the connection proxyHttp//usernamepassword@mydomain.com3128 Http//mydomain.com Weblink.ip.conn12.retryinterval DefaultWeblink.ip.conn12.test.location WebLink Set/Get/Do Commands Weblink.ip.conn12.test.retryinterval Weblink.ip.conn12.test.teston Default failureWebLink Set/Get/Do Commands Weblink.logging.clear This command clears the weblink log entiresSupported Devices Weblink.logging.entriesWeblink.logging.maxentries WebLink Set/Get/Do Commands Weblink.printerresetrequired This command defaults the weblink branch settings Weblink.restoredefaults20/15 P1071336-002 Zebra Technologies Europe Limited