Zebra Technologies P1071336-002 manual Weblink.logging.maxentries

Page 65

WebLink Set/Get/Do Commands

weblink.logging.max_entries

weblink.logging.max_entries

Description This command specifies the maximum number of individual log entries that will be stored in the weblink.logging.entries command.

Important • Changes to this command are immediate and may result in some log entries being lost. If there are N log entries currently in the log, the user sets the max_entires to M, where M is less than N, the oldest (N-M) log entries will be removed.

^JUF, ^JUS, ^JUN, ^JUA, and device.restore_defaults do not have any affect on this setting.

Supported Devices

iMZ 220™, iMZ 320™

QLn220™, QLn320™, QLn420™

ZT210™, ZT220™, ZT230™

Type setvar, getvar, do

Commands

Details

 

 

setvar

This command sets the maximum number of log entires that will be stored.

 

Format: ! U1 setvar "weblink.logging.max_entries" "value"

 

Values: 0 ‐ 10000

 

Note • Setting the value to 0 disables logging.

 

Default: "0"

 

 

getvar

This command returns the setting for the maximum number of log entries that will be stored.

 

Format: ! U1 getvar "weblink.logging.max_entries"

 

 

do

This command sets the maximum number of log entires that will be stored.

 

Format: ! U1 do "weblink.logging.max_entries" "value"

 

Values: 0 ‐ 10000

 

Note • Setting the value to 0 disables logging.

 

Default: "0"

 

 

65

1/20/15

P1071336-002

Image 65
Contents Soti Page 20/15 P1071336-002 P1071336-002 20/15 Contents WebLink Set/Get/Do Commands About This Document How This Document Is Organized Who Should Use This DocumentIcons Used Document ConventionsAbout This Document Introduction Overview What Soti MobiControl Connector DoesSupported Printers Supported Operating SystemsInstallation Minimum System Requirements Installing in a Windows Operating SystemInstall a MobiControl Server Installation StepsInstallation My Documents\zebracerts\ Click Finish Install Software Installation Mypasserver.com Mypc.company.lan Enter the password selected in on Installation Test a Printer Enable Printer DiscoveryInstallation Installation Installation Installation Set Up Printers Discover Your Printers Configuring Printers with WebLink When a Proxy Server is Part of the Network Configuration Configuring WeblinkBasic Configuration To remove authentication credentials issue the following When Http Authentication is NecessaryDifference Between Conn1 and Conn2 Additional Firewall ConfigurationEnable Logging Navigating the Log Output Configuring Printers with WebLink Troubleshooting Locating the Soti MobiControl Connector Log File Installation ErrorsRestarting the Soti MobiControl Connector Value that it was last set to. This does not mean the value SSL/TLS Certificate ErrorsIncorrect. Check that the printer’s date and time rtc.date Communication Other Typical ErrorsTroubleshooting Http Messages Troubleshooting WebLink Set/Get/Do Commands Introduction to SGD Commands Weblink.enable Weblink.ip.conn12.authentication.add Entries Weblink.ip.conn12.authentication.entries Weblink.ip.conn12.authentication.remove Weblink.ip.conn12.enable Weblink.ip.conn12.location Weblink.ip.conn12.maximumsimultaneous connections Weblink.ip.conn12.proxy This command assigns the URL of the connection proxyHttp//usernamepassword@mydomain.com3128 Http//mydomain.com Weblink.ip.conn12.retryinterval DefaultWeblink.ip.conn12.test.location WebLink Set/Get/Do Commands Weblink.ip.conn12.test.retryinterval Weblink.ip.conn12.test.teston Default failureWebLink Set/Get/Do Commands Weblink.logging.clear This command clears the weblink log entiresSupported Devices Weblink.logging.entriesWeblink.logging.maxentries WebLink Set/Get/Do Commands Weblink.printerresetrequired This command defaults the weblink branch settings Weblink.restoredefaults20/15 P1071336-002 Zebra Technologies Europe Limited