Kramer Electronics VS-1616SDI user manual Understanding the Switching Method Settings

Page 36

Using the MENU Command Sequence

8.3.1Understanding the SWITCHING METHOD Settings

Setting the VS-1616SDIunit as a Stand-Alone UNIT provides a choice of 4 SWITCHING METHOD settings:

￿NoVIS - switching occurs immediately after completion of front panel or dry-contact operation or immediately after receiving an RS-232 or RS-485 command, or an IR command. The switching is independent of the vertical reference

￿EXTERNAL SYNC ANALOG - switching occurs during the vertical interval of the video reference signal connected to the ANALOG connector (this signal should be properly terminated via the 75￿ (Term) button1)

￿EXTERNAL SYNC DIGITAL - switching occurs during the vertical interval of the video reference signal connected to the DIGITAL connector

￿INT# 1 DIGITAL - switching occurs during the vertical interval of the video signal connected to Input # 1

Before choosing the EXTERNAL SYNC DIGITAL or the INT# 1 DIGITAL SWITCHING METHOD setting, it is necessary to install a digital Genlock input board2. Without installing the optional digital Genlock input board, these SWITCHING METHOD setting commands will be unavailable.

Setting the VS-1616SDIunit as a Large Matrix (instead of as a Stand-Alone UNIT) provides a choice of 5 SWITCHING METHOD settings:

￿NoVIS, EXTERNAL SYNC ANALOG, EXTERNAL SYNC DIGITAL, INT# 1 DIGITAL, (as described above)

￿MTX (SYNC from Matrix) - the vertical interval of the video reference (selected on one unit in the Large Matrix system) is present on the “SYNC” RS-485 terminal block connector3. This reference signal applies to all switchers in the multi- switcher system and facilitates switching all VS-1616SDIunits simultaneously

To choose the MTX (SYNC from Matrix) setting4 as the example in Figure

14 illustrates:

1 Item 4 in Figure 2

2 Available for purchase as an optional extra

3 Item 6 in Figure 2

4 This sets the matrix sync configuration from another (Master) machine

32

KRAMER: SIMPLE CREATIVE TECHNOLOGY

 

Image 36
Contents Model Contents Upgrading Flash Memory Figures TablesIntroduction Getting StartedOverview Overview Your SDI Video Matrix Switcher Operating a Single MachineVS-1616SDI 16x16 SDI Video Matrix Switcher Feature Function Installing the SDI Video Matrix Switcher Configuring a Standalone SDI Video Matrix SwitcherAssembling a System of Interconnected Switchers Setting the Dipswitches Assembling a System of Interconnected SwitchersSetting the Machine # Understanding the System Mode Connecting a Control Interface Keyboard LockedConnecting a PC to Four Switchers Connecting with a Null-modem Adapter Null-modem adapter Illustrates the RS-485 line that connects An RS-485 Control Interface Setup Configuring the Sync Connecting the Keyboard ExtensionOperating Your SDI Video Matrix Switcher Using the Startup DisplayUsing the Front Panel Buttons Default Startup Status Display SequenceOut # Where x is the output number Out # From in # yAll OUTs Out # Reset Clearing Several Outputs Reset ALL connections Reset ALL ? Press Take to executeEnter Setup number Store this Setup ?Use two digit # # xy Using the Menu Command Sequence Setup # xy Load ?Sequence of Menu Commands Locking and Unlocking the Front Panel Choosing the System Modes Follow the System Yes TAKE, next MenuChoosing the Switching Method Setting Understanding the Switching Method Settings Switching Method setting Yes TAKE, next Menu NoVIS 2 EXT 3 INT#1 4MTX ExternalChoosing the Extended Keyboard Setting Setting the STORE/RECALL Keyboard Mode STORE/RECALL setting Yes TAKE, next MenuSTO/RCL mode Changed At onceChoosing the Communication Setting Setting the IR Remote Control Choosing the Auto Store Current Setup Identifying the MachineChoosing the Initial Reset Initial Reset Yes TAKE, next MenuOutkey 1 Current status Factory default Reset to factory default Press Take to executeConnecting the PC to the RS-232 Port Upgrading Flash MemoryUpgrading the Firmware Ready for receiving Start transmission from PC Program replaced16608D Technical Specifications Hex CodesHex Table for the VS-1616SDI Video Matrix Switcher Ascii Protocol General Ascii Protocol Description#, i# ExampleOK!! or Error Page 2900-002063 REV