1
Overview
This chapter describes the following:
For information about: | Refer to page ... |
|
|
System Description | |
|
|
Features | |
|
|
System Description
The Matrix X4‐C chassis design provides eight slots to seat four Input/Output Modules (IOM), two Fabric Modules (FM), and two Control Modules (CM).
The Matrix X4‐C chassis supports:
•Terabit switching capacity
•Hot swapping of modules
•Redundant power and cooling systems
•Installation in a standard 19‐inch (48.26‐centimeter) wide rack (six chassis can be loaded into a standard 7‐foot [213.36‐centimeter] high rack)
•Protective earth grounding requirements of the National Electrical Code (NEC) UL 60950 and IEC 60950 standards
•Telcordia GR‐1089 Section 9, Bonding and Grounding Requirements, when required
All chassis components (power supplies, fan tray, and modules) are installed from the front of the chassis for ease of maintenance. All LED indicators are observable from the front of the chassis to aid in monitoring network operational status and performing maintenance. Figure 1‐1 illustrates the Matrix X4‐C chassis (front view) as shipped from the factory with coverplates removed from all slots labeled 1 including CM1, FM1, PS1, the first IOM and fan tray slots. Figure 1‐2 illustrates the rear of the chassis showing AC power inlets 1 through 3 and earth grounding holes.