Viking Access Systems H-10 manual Secondary Entrapment Protection

Page 12

IMPORTANT SAFETY INFORMATION

!WARNING! Not Following these instructions may cause severe injury or death.

NOTE: This type on installation does not reverse the gate all the way back to its limits when the photo beam is obstructed. This installation is only to protect against entrapment and to comply with UL325.

Secondary Entrapment Protection

Photo Beam (non-contact sensor) Installation

Photo beams or like must be installed to reduce the risk of entrapment.

Use only Omron E3K-R10K4 photoelectric eye to comply with UL325

Make the electrical connections of the photoelectric sensor as described here in this page.

Care shall be exercised to reduce the risk of nuisance tripping, such as when a ve- hicle, trips the sensor while the gate is still moving, and;

One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.

Consult the installation manual for the UL325 device (photo beam or like) for detail information about the usage, installation and maintenance.

1 0

VIKING TECHNICAL SUPPORT 1.800.908.0884

 

 

Image 12
Contents Instructions Viking H-10 Slide Gate Operator Vehicular Gate Operator Revision H10NXMN10.E December Parts Diagram DescriptionOperator References EMI Board Connector Control Board ReferencesTable of Contents Important Safety Information Important Safety InstructionsImportant Installation Instructions Maintenance UL325 Gate Operator Classifications GlossaryPhoto Beam non-contact sensor Installation Secondary Entrapment ProtectionEdge Sensor contact sensor Installation When manual operation is requiredManual Release Audible Alarm Reset Switch Installation Manual Reset for the Audible AlarmSpecifications Single Phase 50 Hz / 60 HzAlternative Power 24VAC / VDC 60VA or Solar Locate Control ButtonsGate Operator Installation Concrete Pad OptionPost Mounting Option Operator Positioning Step Electrical Installation Tips for proper ground installationHigh Voltage Supply Option Low Voltage Supply Option Solar Supply OptionLimits Setup 1a 1bTo Readjust the Open Limit To Readjust the Close LimitMASTER/SLAVE Setup Two Wire CommunicationMS1 MS2 Wireless Communication Options Required ADD-ON Choose option a or BInitial Settings Timer Hold Open TimerObstruction Detection Sensor Control Board Setup Auto Open Power Failure OptionLast Open Power Failure Option Fail Safe/SecureObstruction Sensor Primary Entrapment Protection ODS Obstruction Detection SensorViking Lock Mode Viking HeaterThis page Left Blank Intentionally Accessory Connections Re-Open Photo Beam vehicular SafetyCOM + Check for proper operationRadio Receiver Typical Open-Stop-CloseOpen Only Anti-Tailgate, Open Commands & Guard Station Open CommandsGuard Station ATG Anti-TailgateViking Loop Rack Accessory Connections Guidelines for Loop InstallationPower for the Locks Magnetic Lock, Lock SolenoidMagnetic Lock Lock Solenoid Synchronization with B-12 Barrier Arm B-12 Synchronization OptionTroubleshooting LED ReferencesTroubleshooting LCD MSG Meaning LCD Display ReferencesTroubleshooting Error Messages Solutions CheckAccess Control Connections Power ConnectionsAppendix a Relays In GeneralGeneral Technical TIP Viking usesCommon Radio Receivers Connections Appendix C Solar ApplicationsPanels Batteries & FuseViking Konnect Diagnostic Tool On-site remote Viking Expansion ProductsViking Konnect Master/Slave Kit Secure and reliable OUR Continuous Commitment to Excellence Standard Features