Viking Access Systems H-10 manual Important Safety Information, Important Safety Instructions

Page 8

IMPORTANT SAFETY INFORMATION

!WARNING! Not Following these instructions may cause severe injury or death.

IMPORTANT SAFETY INSTRUCTIONS

!WARNING! To reduce the risk of severe injury or death.

1. READ AND FOLLOW ALL INSTRUCTIONS.

2.Never let children operate or play with gate controls. Keep the remote away from children.

3.Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.

4.Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or when an object activates the non-contact sensors. After adjusting the force or the limit travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.

5. Use the emergency release only when the gate is not moving.

6.KEEP GATES PROPERLY MAINTAINED. Read the user’s manual. Have a qualified service person make repairs to gate hardware.

7.The entrance is for vehicles only. Pedestrians must use a separate entrance.

8. Every gate operator installation MUST have secondary protection devices against entrapment, such as edge sensors and photo beams more in particularly in places where the risk of entrapment is more likely to occur.

9. SAVE THESE INSTRUCTIONS.

IMPORTANT INSTALLATION INSTRUCTIONS

1. Install the gate operator only when:

a.The operator is appropriate for the construction of the gate and usage Class of the gate (refer to page 9),

b.All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position,

c.ALL EXPOSED PINCH POINTS ARE ELIMINATED OR GUARDED, AND

d.GUARDING IS SUPPLIED FOR EXPOSED ROLLERS.

2.The Operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come into contact with the vehicular gate during the entire path of travel of the vehicular gate.

3.The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open in to the public access areas.

4.The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.

5. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving AND AWAY FROM THE GATE PATH PERIMETER.

6

VIKING TECHNICAL SUPPORT 1.800.908.0884

 

 

Image 8
Contents Instructions Viking H-10 Slide Gate Operator Vehicular Gate Operator Revision H10NXMN10.E December Parts Diagram DescriptionOperator References EMI Board Connector Control Board ReferencesTable of Contents Important Safety Information Important Safety InstructionsImportant Installation Instructions Maintenance UL325 Gate Operator Classifications GlossaryPhoto Beam non-contact sensor Installation Secondary Entrapment ProtectionManual Release Edge Sensor contact sensor InstallationWhen manual operation is required Audible Alarm Reset Switch Installation Manual Reset for the Audible AlarmSpecifications Single Phase 50 Hz / 60 HzAlternative Power 24VAC / VDC 60VA or Solar Locate Control ButtonsGate Operator Installation Concrete Pad OptionPost Mounting Option Operator Positioning Step High Voltage Supply Option Electrical InstallationTips for proper ground installation Low Voltage Supply Option Solar Supply OptionLimits Setup 1a 1bTo Readjust the Open Limit To Readjust the Close LimitMS1 MS2 MASTER/SLAVE SetupTwo Wire Communication Wireless Communication Options Required ADD-ON Choose option a or BObstruction Detection Sensor Initial SettingsTimer Hold Open Timer Control Board Setup Auto Open Power Failure OptionLast Open Power Failure Option Fail Safe/SecureObstruction Sensor Primary Entrapment Protection ODS Obstruction Detection SensorViking Lock Mode Viking HeaterThis page Left Blank Intentionally Accessory Connections Re-Open Photo Beam vehicular SafetyCOM + Check for proper operationOpen Only Radio Receiver TypicalOpen-Stop-Close Anti-Tailgate, Open Commands & Guard Station Open CommandsGuard Station ATG Anti-TailgateViking Loop Rack Accessory Connections Guidelines for Loop InstallationMagnetic Lock Lock Solenoid Power for the LocksMagnetic Lock, Lock Solenoid Synchronization with B-12 Barrier Arm B-12 Synchronization OptionTroubleshooting LED ReferencesTroubleshooting LCD MSG Meaning LCD Display ReferencesTroubleshooting Error Messages Solutions CheckAccess Control Connections Power ConnectionsAppendix a Relays In GeneralGeneral Technical TIP Viking usesCommon Radio Receivers Connections Appendix C Solar ApplicationsPanels Batteries & FuseViking Konnect Master/Slave Kit Secure and reliable Viking Konnect Diagnostic Tool On-site remoteViking Expansion Products OUR Continuous Commitment to Excellence Standard Features