Viking Access Systems H-10 Wireless Communication Options, Required ADD-ON Choose option a or B

Page 25

MASTER/SLAVE SETUP

Wireless Communication Options

!Technical Tip: DO NOT set the “Timer” and/or “Overlap” features on both operators Control Boards. Only turn these features on at the Master Control Board.

REQUIRED ADD-ON: Choose option A or B

A. Viking Konnect - Wireless Master/Slave Kit

PART# VA-KONNECT-MS

B. Viking Blue - Wireless Master/Slave Kit

PART# VA-BLUE-MSKT

Connect the Modules provided to the “V.K” plug & play connection of each operators Control Board. It is not important which board the master or slave module is placed on.

Green LEDs will be illuminated solid when communication is ON.

VIKING TECHNICAL SUPPORT 1.800.908.0884

2 3

 

 

Image 25
Contents Instructions Viking H-10 Slide Gate Operator Vehicular Gate Operator Revision H10NXMN10.E December Description Parts DiagramOperator References Control Board References EMI Board ConnectorTable of Contents Important Safety Instructions Important Safety InformationImportant Installation Instructions Maintenance Glossary UL325 Gate Operator ClassificationsSecondary Entrapment Protection Photo Beam non-contact sensor InstallationWhen manual operation is required Edge Sensor contact sensor InstallationManual Release Manual Reset for the Audible Alarm Audible Alarm Reset Switch InstallationSingle Phase 50 Hz / 60 Hz SpecificationsAlternative Power 24VAC / VDC 60VA or Solar Locate Control ButtonsConcrete Pad Option Gate Operator InstallationPost Mounting Option Operator Positioning Step Tips for proper ground installation Electrical InstallationHigh Voltage Supply Option Solar Supply Option Low Voltage Supply Option 1a 1b Limits SetupTo Readjust the Close Limit To Readjust the Open LimitTwo Wire Communication MASTER/SLAVE SetupMS1 MS2 Required ADD-ON Choose option a or B Wireless Communication OptionsTimer Hold Open Timer Initial SettingsObstruction Detection Sensor Auto Open Power Failure Option Control Board SetupLast Open Power Failure Option Fail Safe/SecureODS Obstruction Detection Sensor Obstruction Sensor Primary Entrapment ProtectionViking Heater Viking Lock ModeThis page Left Blank Intentionally Re-Open Photo Beam vehicular Safety Accessory ConnectionsCOM + Check for proper operationOpen-Stop-Close Radio Receiver TypicalOpen Only Open Commands Anti-Tailgate, Open Commands & Guard StationGuard Station ATG Anti-TailgateViking Loop Rack Guidelines for Loop Installation Accessory ConnectionsMagnetic Lock, Lock Solenoid Power for the LocksMagnetic Lock Lock Solenoid Barrier Arm B-12 Synchronization Option Synchronization with B-12LED References TroubleshootingTroubleshooting LCD Display References LCD MSG MeaningTroubleshooting Error Messages Check SolutionsPower Connections Access Control ConnectionsRelays In General Appendix aGeneral Technical TIP Viking usesCommon Radio Receivers Connections Solar Applications Appendix CPanels Batteries & FuseViking Expansion Products Viking Konnect Diagnostic Tool On-site remoteViking Konnect Master/Slave Kit Secure and reliable OUR Continuous Commitment to Excellence Standard Features