Viking Access Systems H-10 manual Troubleshooting

Page 39
3 7

TROUBLESHOOTING

LED References

Use the table below to identify the corresponding “TS Ref#” and refer to page 38-41 for

further troubleshooting.

 

Pg 41

#

LED

Status

Meaning

TS Ref#(s)

9

“C Loop”

OFF

Normal Condition.

 

 

 

SOLID

Control Board is receiving an input from a device connected to the

9, 10

 

 

 

C Loop terminal (pgs 32, 42).

10

“Open”

OFF

Normal Condition.

 

 

 

SOLID

Control board is receiving an input for a device connected to any of

9, 10

 

 

 

the following input terminals: Exit, Fire, Strike or Open (pgs 31, 42).

11

“STOP”

OFF

Normal Condition.

 

 

 

SOLID

Control Board is receiving an input from a device connected to the

9, 10

 

 

 

Stop terminal (pgs 31, 42).

12

“Close”

OFF

Normal Condition.

 

 

 

SOLID

Control Board is receiving an input from a device connected to the

9, 10

 

 

 

Close terminal (pgs 31, 42).

13

“Siren”

OFF

Normal Condition.

 

 

 

SOLID

Second consecutive obstruction has been detected. (pg 26).

11, 13, 1, 2

 

 

FLASHING

Batteries are critically low.

1, 2

14

“Aux. Pwr”

OFF

No voltage output on these terminals at the moment.

 

 

 

SOLID

There is 24v DC output on these terminals at the moment.

 

15

“Diagnose”

OFF

Normal Condition.

 

 

 

FLASHING

Errors have been detected; Check LCD Display for ERR messages (pg 40).

 

16

“Close Limit”

OFF

Gate is not at the close limit position.

 

 

 

SOLID

Gate is at the close limit position.

 

 

 

FLASHING

Close limit position has been erased or not set (pg 20-21).

6

17

“Open Limit”

OFF

Gate is not at the open limit position.

 

 

 

SOLID

Gate is at the open limit position.

 

 

 

FLASHING

Open limit position has been erased or not set (pg 20-21).

6

18

“ODS”

OFF

Normal Condition.

 

 

 

SOLID

Obstruction has been detected. (pg 26).

11, 13, 1, 2

 

 

FLASHING

Overload has been detected. (pg 26).

11, 13, 1, 2

19

“Timer”

OFF

The close timer is turned OFF or gate is not at the open limit if the timer is

 

 

 

 

turned ON. (pg 24).

 

 

 

SOLID

Gate is at Open Limit, Timer is turned ON and counting down to close. (pg

 

 

 

 

24).

 

 

 

FLASHING

Gate is at Open Limit, Timer is turned ON but is not timing out due to a

9, 10

 

 

 

conflicting command. (pg 24).

20

“AC VOLTAGE INPUT”

SOLID

Normal Condition.

 

 

 

OFF

Incoming power to Power Supply Panel Assembly is not sufficient.(pg 18).

1

21

“PROTECTION WORKING” SOLID

Normal Condition.

 

 

 

OFF

EMI Board is damaged and circuit is not protected . Replace EMI Board.

 

22

“AC VOLTAGE OUTPUT”

SOLID

Normal Condition.

 

 

 

OFF

There is no output voltage from the Power Supply Panel Assembly.

2

23

“AC POWER”

SOLID

Normal Condition for High Voltage installations.

 

 

 

OFF

High Voltage is not supplied to the Modular Power Box (pg 18).

1

VIKING TECHNICAL SUPPORT 1.800.908.0884

Image 39
Contents Instructions Viking H-10 Slide Gate Operator Vehicular Gate Operator Revision H10NXMN10.E December Description Parts DiagramOperator References Control Board References EMI Board ConnectorTable of Contents Important Safety Instructions Important Safety InformationImportant Installation Instructions Maintenance Glossary UL325 Gate Operator ClassificationsSecondary Entrapment Protection Photo Beam non-contact sensor InstallationEdge Sensor contact sensor Installation When manual operation is requiredManual Release Manual Reset for the Audible Alarm Audible Alarm Reset Switch InstallationLocate Control Buttons SpecificationsSingle Phase 50 Hz / 60 Hz Alternative Power 24VAC / VDC 60VA or SolarConcrete Pad Option Gate Operator InstallationPost Mounting Option Operator Positioning Step Electrical Installation Tips for proper ground installationHigh Voltage Supply Option Solar Supply Option Low Voltage Supply Option1a 1b Limits SetupTo Readjust the Close Limit To Readjust the Open LimitMASTER/SLAVE Setup Two Wire CommunicationMS1 MS2 Required ADD-ON Choose option a or B Wireless Communication OptionsInitial Settings Timer Hold Open TimerObstruction Detection Sensor Fail Safe/Secure Control Board SetupAuto Open Power Failure Option Last Open Power Failure OptionODS Obstruction Detection Sensor Obstruction Sensor Primary Entrapment ProtectionViking Heater Viking Lock ModeThis page Left Blank Intentionally Check for proper operation Accessory ConnectionsRe-Open Photo Beam vehicular Safety COM +Radio Receiver Typical Open-Stop-CloseOpen Only ATG Anti-Tailgate Anti-Tailgate, Open Commands & Guard StationOpen Commands Guard StationViking Loop Rack Guidelines for Loop Installation Accessory ConnectionsPower for the Locks Magnetic Lock, Lock SolenoidMagnetic Lock Lock Solenoid Barrier Arm B-12 Synchronization Option Synchronization with B-12LED References TroubleshootingTroubleshooting LCD Display References LCD MSG MeaningTroubleshooting Error Messages Check SolutionsPower Connections Access Control ConnectionsTechnical TIP Viking uses Appendix aRelays In General GeneralCommon Radio Receivers Connections Batteries & Fuse Appendix CSolar Applications PanelsViking Konnect Diagnostic Tool On-site remote Viking Expansion ProductsViking Konnect Master/Slave Kit Secure and reliable OUR Continuous Commitment to Excellence Standard Features