Viking Access Systems H-10 manual Control Board References, EMI Board Connector

Page 6

CONTROL BOARD REFERENCES:

1.POWER HARNESS CONNECTOR provides power to the control board. pg 18-19

2.“OPEN LEFT” & “OPEN RIGHT” provides power to the motor. pg 20

3.LIMIT SETUP BUTTONS

sets limit positions. pg 20-21

4.FEATURE ACTIVATION TRIM POTS activate and set features. pg 24

5.“EPS1” CONNECTOR

available for future developments

6.“EPS2” CONNECTOR monitors the limit positions.

7.EMI BOARD CONNECTOR

monitors the high voltage power supply.

8.“CHECK MOTOR” Status LED indicates motor power status. pg 36

9.“BATTERY LOW” Status LED

indicates battery power status. pg 36

10.“POWER” Status LED

control board power status. pg 18,36

11.“MAGNETIC LOCK RELAY” Status LED status of this on-board relay. pg 34, 36

12.“MAGNETIC LOCK RELAY” Terminal Block connect electric locks here. pg 34, 36

13.INPUT STATUS LEDs

indicates input status. pg 36-37

14.ACCESS CONTROL TERMINAL BLOCKS accessory connections. pg 29-32, 42-44

15.“MASTER/SLAVE” Terminal Block wired master/slave connection. pg 22

16.CONTROL BOARD MOUNTING HOLES secures and grounds the control board.

17.“Siren” Terminal Block

Vikings UL Siren is connected here.

18.ON-BOARD 3 BUTTON STATION controls the gate during set up.

19.“AUX. PWR” Terminal Block

used for solar applications & in-motion warning devices. pg 19, 25

20.FEATURE ACTIVATION PIN HEADERS activate features by placing a jumper onto the pin headers. pg 25

21.“DIAGNOSE” Button

allows you to navigate through the Diagnostics LCD Display. pg 38-40

22.“DIAGNOSE” LED

informs that errors have been detected and available on LCD Display. pg 38-40

23.LCD DIAGNOSTICS DISPLAY

provides error messages, diagnostics and operator status information. pg 38-40

24.EXPANSION PRODUCT CONNECTIONS connections for additional products from Viking Access Systems. pg 46

25.“FAIL SAFE/SECURE” Jumper

power failure option. pg 25

26.FUSE HOLDER - 20 AMP for motor circuit.

27.FUSE HOLDER - 4 AMP for charging circuit.

28.HEAT SINK

secures the control board and dissipates heat.

4

VIKING TECHNICAL SUPPORT 1.800.908.0884

 

 

Image 6
Contents Instructions Viking H-10 Slide Gate Operator Vehicular Gate Operator Revision H10NXMN10.E December Parts Diagram DescriptionOperator References EMI Board Connector Control Board ReferencesTable of Contents Important Safety Information Important Safety InstructionsImportant Installation Instructions Maintenance UL325 Gate Operator Classifications GlossaryPhoto Beam non-contact sensor Installation Secondary Entrapment ProtectionEdge Sensor contact sensor Installation When manual operation is requiredManual Release Audible Alarm Reset Switch Installation Manual Reset for the Audible AlarmAlternative Power 24VAC / VDC 60VA or Solar SpecificationsSingle Phase 50 Hz / 60 Hz Locate Control ButtonsGate Operator Installation Concrete Pad OptionPost Mounting Option Operator Positioning Step Electrical Installation Tips for proper ground installationHigh Voltage Supply Option Low Voltage Supply Option Solar Supply OptionLimits Setup 1a 1bTo Readjust the Open Limit To Readjust the Close LimitMASTER/SLAVE Setup Two Wire CommunicationMS1 MS2 Wireless Communication Options Required ADD-ON Choose option a or BInitial Settings Timer Hold Open TimerObstruction Detection Sensor Last Open Power Failure Option Control Board SetupAuto Open Power Failure Option Fail Safe/SecureObstruction Sensor Primary Entrapment Protection ODS Obstruction Detection SensorViking Lock Mode Viking HeaterThis page Left Blank Intentionally COM + Accessory ConnectionsRe-Open Photo Beam vehicular Safety Check for proper operationRadio Receiver Typical Open-Stop-CloseOpen Only Guard Station Anti-Tailgate, Open Commands & Guard StationOpen Commands ATG Anti-TailgateViking Loop Rack Accessory Connections Guidelines for Loop InstallationPower for the Locks Magnetic Lock, Lock SolenoidMagnetic Lock Lock Solenoid Synchronization with B-12 Barrier Arm B-12 Synchronization OptionTroubleshooting LED ReferencesTroubleshooting LCD MSG Meaning LCD Display ReferencesTroubleshooting Error Messages Solutions CheckAccess Control Connections Power ConnectionsGeneral Appendix aRelays In General Technical TIP Viking usesCommon Radio Receivers Connections Panels Appendix CSolar Applications Batteries & FuseViking Konnect Diagnostic Tool On-site remote Viking Expansion ProductsViking Konnect Master/Slave Kit Secure and reliable OUR Continuous Commitment to Excellence Standard Features