Viking Access Systems H-10 manual Access Control Connections, Power Connections

Page 44

Appendix (A)

Access Control Connections

Power Connections

The control board provides a 24VDC output to power external devices and controls. Alternatively, for devices that require a power supply other than 24VDC, the operators Power Box contains a convenient 120VAC receptacle to connect a plug-in transformer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“C”

=

Common

Terminals Connections and Input Functions:

 

 

“N.O.”

=

Normally Open

 

 

 

 

 

 

 

 

Viking Terminal

Function

 

 

Device Terminal

“+28v” ---------------------

DC Positive

---------------

 

+

“GND” ---------------------

DC Negative

---------------

 

“GND” ---------------------

Relay Common ---------------

 

“C”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Radio”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“N.O.”

 

 

----------------------------------------

 

 

 

 

 

---------------------

 

 

 

 

 

 

 

 

 

 

If “Timer” OFF:

Open - Stop - Close

 

 

 

 

 

 

 

 

 

 

 

 

 

If “Timer” ON:

Open / Reopen if closing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see pages 10 & 11)

 

 

 

 

 

 

 

“UL”

 

 

 

 

 

 

 

 

 

“N.O.”

 

 

 

 

 

 

 

 

If input is brief:

Stops gate then Reverses 12 inches

 

 

 

 

 

 

 

 

If input is longer:

Stops gate, does not reverse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Re-Open”

 

 

 

 

 

 

“N.O.”

 

 

 

 

 

 

 

 

If stopped:

No function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If closing:

Stops then Opens gate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anti-Tailgate

 

 

 

 

 

 

 

“ATG”

 

 

 

 

 

 

 

“N.O.”

 

 

 

 

 

 

 

 

Input is received:

Stops gate if closing

 

 

 

 

 

 

 

 

 

 

 

 

 

Input is released:

Closes gate to prevent tailgating

 

 

 

 

 

 

 

 

 

 

 

 

“C. Loop”

 

 

 

 

 

 

“N.O.”

 

 

 

 

 

 

 

 

If not at open limit:

No function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If at open limit:

Prevents gate from Closing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Open”, “Exit”, “Fire” & “Strike”

 

 

 

 

 

 

“N.O.”

 

 

 

 

 

 

 

 

If stopped:

Opens gate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If closing:

Stops then Opens gate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Stop”

 

 

 

 

 

 

“N.O.”

 

 

 

 

 

 

 

 

If traveling:

Stops gate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Close”

 

 

 

 

 

 

“N.O.”

 

 

 

 

 

 

 

 

If stopped:

Closes gate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If traveling:

No function

 

 

 

 

 

 

!TECHNICAL TIP: Each input Terminal (i.e. Radio, Exit, Re-Open, UL) has a corresponding Status LED that when illuminated indicates an input is currently being provided to the terminal and the gate is responding accordingly. (See pages 36-37 LED References)

4 2

VIKING TECHNICAL SUPPORT 1.800.908.0884

 

 

Image 44
Contents Instructions Viking H-10 Slide Gate Operator Vehicular Gate Operator Revision H10NXMN10.E December Parts Diagram DescriptionOperator References EMI Board Connector Control Board ReferencesTable of Contents Important Safety Information Important Safety InstructionsImportant Installation Instructions Maintenance UL325 Gate Operator Classifications GlossaryPhoto Beam non-contact sensor Installation Secondary Entrapment ProtectionManual Release Edge Sensor contact sensor InstallationWhen manual operation is required Audible Alarm Reset Switch Installation Manual Reset for the Audible AlarmSpecifications Single Phase 50 Hz / 60 HzAlternative Power 24VAC / VDC 60VA or Solar Locate Control ButtonsGate Operator Installation Concrete Pad OptionPost Mounting Option Operator Positioning Step High Voltage Supply Option Electrical InstallationTips for proper ground installation Low Voltage Supply Option Solar Supply OptionLimits Setup 1a 1bTo Readjust the Open Limit To Readjust the Close LimitMS1 MS2 MASTER/SLAVE SetupTwo Wire Communication Wireless Communication Options Required ADD-ON Choose option a or BObstruction Detection Sensor Initial SettingsTimer Hold Open Timer Control Board Setup Auto Open Power Failure OptionLast Open Power Failure Option Fail Safe/SecureObstruction Sensor Primary Entrapment Protection ODS Obstruction Detection SensorViking Lock Mode Viking HeaterThis page Left Blank Intentionally Accessory Connections Re-Open Photo Beam vehicular SafetyCOM + Check for proper operationOpen Only Radio Receiver TypicalOpen-Stop-Close Anti-Tailgate, Open Commands & Guard Station Open CommandsGuard Station ATG Anti-TailgateViking Loop Rack Accessory Connections Guidelines for Loop InstallationMagnetic Lock Lock Solenoid Power for the LocksMagnetic Lock, Lock Solenoid Synchronization with B-12 Barrier Arm B-12 Synchronization OptionTroubleshooting LED ReferencesTroubleshooting LCD MSG Meaning LCD Display ReferencesTroubleshooting Error Messages Solutions CheckAccess Control Connections Power ConnectionsAppendix a Relays In GeneralGeneral Technical TIP Viking usesCommon Radio Receivers Connections Appendix C Solar ApplicationsPanels Batteries & FuseViking Konnect Master/Slave Kit Secure and reliable Viking Konnect Diagnostic Tool On-site remoteViking Expansion Products OUR Continuous Commitment to Excellence Standard Features