Bosch Appliances MIC412 operation manual Table I Camera Interface Control Settings DIP Switch

Page 21

MIC412TI and MIC412TF Camera Installation and Operation Manual

With all the above set up, when Camset is running and the serial port selected, set the Camera Interface Controls to the following:-

Table I – Camera Interface Control Settings

 

 

 

 

 

DIP Switch

 

Setting

 

 

 

OFF

 

 

 

 

Sw 1

 

 

 

 

OFF

 

Sw 2

 

 

 

 

OFF

 

Sw 3

 

 

 

 

ON

 

Sw 4

 

 

 

 

OFF

 

Sw 5

 

 

 

 

ON

 

Sw 6

 

 

 

 

 

If a notebook PC is used, which sometimes lacks a serial port, then a RS485 to USB converter such as the MIC-USB485CVTR can be used instead, this would typically be mapped to Comms port 3 or 4.

 

 

 

 

 

EN 21

 

Connecting the MIC-USB485CVTR, USB to RS485 Converter

 

 

 

 

 

 

 

 

 

Camset Tabs

2 Wire RS485

4 Wire RS422

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comms 1

 

Selected

 

Selected

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interface

 

2 Wire

 

4 Wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RTS

 

Off

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud

 

9600

 

9600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The MIC-USB485CVTR is a USB to RS485 signal converter that allows PCs without a serial port to connect directly to the MIC400 series camera via the telemetry connection (HD4) in the power supply, the MIC-USB485CVTR can also be used to connect a PC to any other RS485 device.

The MIC-USB485CVTR has been designed to work with all functions in Universal Camset and to be backwards compatible with legacy version of Camset although full compatibility is not guaranteed.

The MIC-USB485CVTR should be connected to the telemetry header (HD4) of the MIC power supply with Standard Twisted Pair cable such as Belden 8760.

Bosch Security Systems

Issue 8

Image 21
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Appendices Glossary of TermsIntroduction MIC412 Camera Versions MIC 412 Power Supply Unit Versions and OptionsPackaging Contents FeaturesMIC 412 Options WiperInstallation Environment Bosch Security Systems Issue Key to MIC-PMB drawing Associated Equipment and Typical InstallationsInstallation Instructions Hardware InstallationEarthing of the MIC 412 camera Lightning ProtectionElectrical Connections Power Supply Layout and Connections MIC 412TI and MIC 412TF Power Supply UnitsMIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL PCB Earth LinkTable D -Telemetry Connections to HD3, HD4 and HD5 HD3Terminal Box ID Marking Fuse Fuse function Terminal Box ConnectorRating for 240v Primary Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Connecting the Greenwich Adaptor Connecting the MIC 412 to the PCTable G Connecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorTable I Camera Interface Control Settings DIP Switch Connecting the MIC-USB485CVTR, USB to RS485 ConverterCamset Tabs Wire RS485 Wire RS422 HD4 or HD5 MIC-USB485CVTR and Universal Camset Software InstallationMIC Settings Boot MessagesCommissioning the MIC412 through Universal Camset Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Iris Controls Preset PositionsFocus Controls AuxiliariesPreset Tours Tour ControlsPattern Tours Soft Stops and Non Dwell Zones MIC SetupsNon-Dwell Zone ClearGeneral Settings Other controls Auto Home ControlsDefault Settings Learn Alarm Positions Multi Alarm SettingsFrame Integration Settings Relay State, Activation and Re-armPrivacy Controls Privacy and CaptionsPrivacy Calibration Captions Thermal FFC Mode and SettingsShutter Open/Close Gain and Auto Gain ModesTemperature and Humidity Advanced SettingsTimers Clear All StatisticsOnly Eeprom CopierDownload Eeprom To File Upload Eeprom From FilePOT Test Manual and Preset / Goto ControlsMenu Controls Panasonic Only Matrix ControlsVisible Traces Pot Test ControlsComms Pot Test ResultsMouse Point Values Send Direct Command Alarms Communications TestingMIC Comms Cam CommsSend Preset to MIC Get Preset from MICSony Set SonySet ControlsLoad Table from File to MIC Execute this PresetSave Table from MIC to File Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Learning a preset Help MIC412 Preset Codes for the Thermal ImagerBosch Protocol Aux Number Aux On Function Aux Off Function Go to a preset36x optical zoom module MIC412TI and TF Dual Optical/Thermal PTZ CameraConnectivity Appendix a Sonyset Camera Commands Dimension DrawingsMIC 412 models Upright 90 Dimension Drawings Pelco Appendix B Protocol Preset CodesWashwipeonpreset Washwipeoffpreset Vision Special Setup PresetsAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Europe, Middle East, Africa Contact AmericasAsia-Pacific Bosch Security Systems IncBosch Security Systems, Inc