MIC412 Camera Versions

This manual covers the installation & operation of the following MIC 412TI and MIC 412TF Dual optical thermal PTZ cameras, briefly described below:-

MIC 412TI The MIC 412TI is made from machined and cast aluminium and is then pre-treated and painted with two part epoxy power coat paint in either RAL 9003 (Signal White)or RAL9005 (Jet Black), other colours are available on request.. This unit incorporates a choice of 18x or 36x Day/Night optical camera paired with a 50mm 9Hz Flir Thermal Imager.

MIC41 2TF The MIC 412TF camera is made to the same specification as the MIC412TI but fitted with a 25Hz Flir Thermal Imager, the 18x and 36x Day/Night optical camera choices remain.

EN 8

MIC 412 Power Supply Unit Versions and Options

CAUTION: Only use the specified power supplies with the

MIC 412.

Bosch Security Systems have designed a range of power supplies for the MIC412 cameras to cater for a variety of common voltages and provide all the connections needed for power, telemetry and video. The power supply units and options are detailed below. Refer to the MIC Series Power Supplies Installation Manual.

For MIC412 cameras only:-

 

MIC-240PSU-UL

240VAC input Power Supply Unit

MIC-115PSU-UL

115VAC input Power Supply Unit

MIC-24PSU-UL

24 VAC input Power Supply Unit

DANGER:. ELECTRICAL SHOCK HAZARD

Ensure the power is disconnected prior to opening the power supply enclosure. Power must be disconnected before replacing any fuse in the MIC PSU.

The MIC power supplies have a separate internal shield covering the power cable input header (HD1).

Only suitably qualified persons should remove this shield and connect the mains power cable, the shield MUST be re- fitted and fully secured prior to connecting the power.

The mains supply cable shall have conductors of a maximum size of 12 AWG. A readily accessible disconnect device (circuit breaker) shall be incorporated externally to the equipment. The recommended rating is 15 A.

Bosch Security Systems

Issue 8

Image 8
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Terms Glossary of AppendicesIntroduction MIC 412 Power Supply Unit Versions and Options MIC412 Camera VersionsFeatures Packaging ContentsMIC 412 Options WiperInstallation Environment Bosch Security Systems Issue Associated Equipment and Typical Installations Key to MIC-PMB drawingHardware Installation Installation InstructionsElectrical Connections Earthing of the MIC 412 cameraLightning Protection MIC 412TI and MIC 412TF Power Supply Units Power Supply Layout and ConnectionsMIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL PCB Earth LinkHD3 Table D -Telemetry Connections to HD3, HD4 and HD5Terminal Box Connector Terminal Box ID Marking Fuse Fuse functionRating for 240v Primary Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Connecting the MIC 412 to the PC Connecting the Greenwich AdaptorTable G Connecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorCamset Tabs Wire RS485 Wire RS422 Table I Camera Interface Control Settings DIP SwitchConnecting the MIC-USB485CVTR, USB to RS485 Converter MIC-USB485CVTR and Universal Camset Software Installation HD4 or HD5Boot Messages MIC SettingsCommissioning the MIC412 through Universal Camset Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Preset Positions Iris ControlsFocus Controls AuxiliariesPattern Tours Preset ToursTour Controls MIC Setups Soft Stops and Non Dwell ZonesNon-Dwell Zone ClearGeneral Settings Auto Home Controls Other controlsDefault Settings Multi Alarm Settings Learn Alarm PositionsFrame Integration Settings Relay State, Activation and Re-armPrivacy and Captions Privacy ControlsPrivacy Calibration Captions FFC Mode and Settings ThermalShutter Open/Close Gain and Auto Gain ModesAdvanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier OnlyDownload Eeprom To File Upload Eeprom From FileManual and Preset / Goto Controls POT TestMenu Controls Panasonic Only Matrix ControlsPot Test Controls Visible TracesMouse Point Values CommsPot Test Results Send Direct Command Communications Testing AlarmsMIC Comms Cam CommsGet Preset from MIC Send Preset to MICSony Set SonySet ControlsExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Help MIC412 Preset Codes for the Thermal Imager Learning a presetGo to a preset Bosch Protocol Aux Number Aux On Function Aux Off FunctionMIC412TI and TF Dual Optical/Thermal PTZ Camera 36x optical zoom moduleConnectivity MIC 412 models Upright 90 Dimension Drawings Appendix a Sonyset Camera CommandsDimension Drawings Appendix B Protocol Preset Codes PelcoWashwipeonpreset Washwipeoffpreset Special Setup Presets VisionAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncBosch Security Systems, Inc