Bosch Appliances MIC412 operation manual Camset Settings

Page 24

MIC412TI and MIC412TF Camera Installation and Operation Manual

Configure MIC Communications

This button opens up a new window which provides the options to reconfigure the MIC communications settings. These options will depend on the MIC model connected.

In order for any of these modifications to work, Camset must have full communications with the MIC. Ensure this by performing a simple manual control test (Up, Down, etc). To store the new settings press Apply once the modifications have been made or alternatively press Cancel to discard any changes.

New Address

This input box defines the new address the MIC should change to once Apply has been clicked. The value will also be copied over into Current Address on the main form to provide continual control.

New Protocol

The drop down list here provides a full list of the protocols available in Camset. Control depends upon selecting the correct protocol in the drop down list to match the protocol that is loaded onto the MIC412; if the incorrect protocol is selected in Camset the MIC may not respond. To regain control should this happen, reset the Camset Protocol back to what the MIC originally was.

EN 24

New Baud Rate

This drop down list will provide the valid baud rates for the chosen protocol. The baud rate options reflect the protocol as set on the main form for Camset itself. In FV protocol the option is a toggle which simply switches the MIC between 4800 and 9600. If control is not present after the window is closed, try changing the Camset Baud Rate.

Reset MIC

This sends out a command to reboot the software. This is not a hardware reboot; the only way to do that is to remove the power supply to the MIC.

Camset Settings

The Camset Settings section as shown above control the Protocol, MIC model, Baud Rate and Comm Port used; select the appropriate parameters for your MIC400 from the dropdown menus.

Some functions in Universal Camset may not be supported by particular protocols; any incompatible functions will be greyed out if it is not supported in a given protocol.

The communication settings will be set to the default for the chosen protocol, indicating this on the Camset Baud Rate drop down list.

Bosch Security Systems

Issue 8

Image 24
Contents MIC412 Dual Optical / Thermal PTZ Camera MIC 412 Dual Optical / Thermal PTZ Camera Power Supply Installation and Camera Setup… Safety Precautions Important Safety Instructions Glossary of Terms Glossary of AppendicesIntroduction MIC 412 Power Supply Unit Versions and Options MIC412 Camera VersionsFeatures Packaging ContentsMIC 412 Options WiperInstallation Environment Bosch Security Systems Issue Associated Equipment and Typical Installations Key to MIC-PMB drawingHardware Installation Installation InstructionsEarthing of the MIC 412 camera Lightning ProtectionElectrical Connections MIC 412TI and MIC 412TF Power Supply Units Power Supply Layout and ConnectionsMIC-24PSU-UL, MIC-115PSU-UL, and MIC-240PSU-UL PCB Earth LinkHD3 Table D -Telemetry Connections to HD3, HD4 and HD5Terminal Box Connector Terminal Box ID Marking Fuse Fuse functionRating for 240v Primary Rating for 115v PrimaryCommissioning the MIC 412 with heater option fitted Fitting the optional Sunshield Connecting the MIC 412 to the PC Connecting the Greenwich AdaptorTable G Connecting the Greenwich Adaptor Connecting the KK systems K2-ADE RS232 to RS485/422 AdaptorTable I Camera Interface Control Settings DIP Switch Connecting the MIC-USB485CVTR, USB to RS485 ConverterCamset Tabs Wire RS485 Wire RS422 MIC-USB485CVTR and Universal Camset Software Installation HD4 or HD5Boot Messages MIC SettingsCommissioning the MIC412 through Universal Camset Standard ControlsCamset Settings Manual Control Pan, Tilt and Zoom Controls Preset Positions Iris ControlsFocus Controls AuxiliariesPreset Tours Tour ControlsPattern Tours MIC Setups Soft Stops and Non Dwell ZonesNon-Dwell Zone ClearGeneral Settings Auto Home Controls Other controlsDefault Settings Multi Alarm Settings Learn Alarm PositionsFrame Integration Settings Relay State, Activation and Re-armPrivacy and Captions Privacy ControlsPrivacy Calibration Captions FFC Mode and Settings ThermalShutter Open/Close Gain and Auto Gain ModesAdvanced Settings Temperature and HumidityTimers Clear All StatisticsEeprom Copier OnlyDownload Eeprom To File Upload Eeprom From FileManual and Preset / Goto Controls POT TestMenu Controls Panasonic Only Matrix ControlsPot Test Controls Visible TracesComms Pot Test ResultsMouse Point Values Send Direct Command Communications Testing AlarmsMIC Comms Cam CommsGet Preset from MIC Send Preset to MICSony Set SonySet ControlsExecute this Preset Load Table from File to MICSave Table from MIC to File Clear TableTable K Sonyset Commands Value MIC Programmer Bosch Security Systems Issue Help MIC412 Preset Codes for the Thermal Imager Learning a presetGo to a preset Bosch Protocol Aux Number Aux On Function Aux Off FunctionMIC412TI and TF Dual Optical/Thermal PTZ Camera 36x optical zoom moduleConnectivity Appendix a Sonyset Camera Commands Dimension DrawingsMIC 412 models Upright 90 Dimension Drawings Appendix B Protocol Preset Codes PelcoWashwipeonpreset Washwipeoffpreset Special Setup Presets VisionAmerican Dynamics Special Setup Presets Kalatel Molynx Autoironpreset Autoiroffpreset Multialarmonpreset Panasonic Bosch Forward Vision Intermitantwipeonpreset Intermitantwipeoffpreset VCL Vicon Rightpreset Softlimitbottom Multialarmpreset Contact Americas Europe, Middle East, AfricaAsia-Pacific Bosch Security Systems IncBosch Security Systems, Inc